Outline of Settings [Measurement mode]

The output will not operate for 3 seconds after supplying power.
Measurement mode is the condition where the flow is detected and displayed, and the
switch function is operating.
This is the basic mode; other modes should be selected for set-point changes and other
function settings.
Sub display
In measurement mode, the sub display can be temporarily changed (for 30 seconds) by pressing
the UP or DOWN button.
After 30 seconds, it will automatically reset to the display selected in [F10]. (Refer to page 53)
(Example shown is for 500 L/min type)
∗1: IO-Link compatible PF2MC7##-L series only.
∗2: An arbitrary display can be added to the sub display by setting in [F10].
If the sub display is switched during the arbitrary display, the display will return to the arbitrary display 30 seconds later.
(The default setting does not include arbitrary display).
Press the
SET button
once.
Flow Setting
(set value only)
of OUT1 · OUT2
[3 step setting mode]
(Refer to page 30.)
∗: The outputs will continue to operate during setting.
∗: If a button operation is not performed for 30 seconds during the setting, the display will flash (This is to prevent the setting from
remaining incomplete if, for instance, an operator were to leave during setting).
∗: 3 step setting mode and Function selection mode are reflected on each other.
Power is supplied
The identification code of the product is displayed.
[Measurement mode]
Function Setting
[Function selection mode]
(Refer to page 33.)
Press the
SET button
for 2 seconds
or longer.
-29-
Other Functions
(Refer to page 72.)
No.PF※※-OMZ0002