Lennox ELITE Series Installation Instructions Manual page 43

Downflow air discharge
Table of Contents

Advertisement

EL296 Field Wiring Applications With Conventional Thermostat
DIP Switch 1
Thermostat
Thermostat
Heating
Stages
Dual Fuel
Single Stage
OFF
Heat Pump
ComfortSense
thermostat w/
bilities
Capable of 2
stage gas heat
control
Dual Fuel
Two Stage
OFF
Heat Pump
ComfortSense
thermostat w/
bilities
Capable of 2
stage gas heat
control
* Connect W1 to W1 ONLY if using defrost tempering kit 67M41
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the furnace
integrated control.
DIP Switch Settings and On-Board Links
On Board Links Must Be Cut To Select
System Options
CUT ON-BOARD LINK
W951
HEAT
PUMP
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W951
HEAT
PUMP
TABLE 15
Page 43
Wiring Connections
FURNACE
HEAT PUMP
T'STAT
TERM. STRIP
H
67M41*
L
Y2
D
B
Y2
T
T
FURNACE
T'STAT
TERM. STRIP
HEAT PUMP
H
67M41*
L
Y2
D
B
T
outdoor
sensor
T
L
Y
outdoor
sensor
L
Y2
out blue

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

El296dfeElite el296dfe seriesElite el296df045xe36bElite el296df070xe48bElite el296df090xe48cElite el296df110xe60c ... Show all