4
Technical Specifications
4.1
Conformity to Standards
EU-Directive(s)
2014/34/EU
2014/30/EU
2014/35/EU
2011/65/EU
4.2
Power Supply
Supply voltage: + 6 V... + 30 V DC.
Max. supply current: see certificates from chapter 2.3.
For use in zone 2: see certificates from chapter 2.3.
The sensors of the A5S1...-n series may only be operated in hazardous area zone 2.
Current consumption: approx. 15 mA (one channel sensor) resp. 25 mA (two channel sensor),
plus load (can increase up to 60 mA with long transmission length and high signal frequency).
If power supply isn't provided by a BRAUN device, a PELV resp. SELV power supply has to be
used.
4.3
Signal Output
Rectangular pulses with constant high level and low level over the entire speed
Push-Pull amplified output. Maximum load 20 mA.
The signal output is short circuit proof and protected against polarity error.
4.4
Speed (Frequency-) Range
Speeds with a maximum signal frequency of:
A5S1DS...-n: 0 Hz...12 kHz
A5S1DD...-n: 0 Hz...25 kHz
4.5
Signal Transmission
Cable in shielded version LiYCY with 3x0.5 mm
150 pF/m).
4.6
Electrical Protective Measures
Protection class: no protection needed
IP code:
4.7
Connection
Connection with screw-plug-in connection (straight or angled) or with fixed PVC (up to 85°C) or
Teflon® (up to 125°C) cable.
4.8
Permissible Ambient Temperature
See certificates from chapter 2.3.
4.9
Installation Dimensions
The sensors are available with different installation threads (D) metric, resp. inch, resp. inch with
NPT, and each with a number of different nominal lengths (L). This is the length from the front
surface of the sensor to the end of the mounting thread (see figures on chapter 7).
ATEX product directive
EMC directive
Low voltage directive
RoHS directive
IP67, pressure-tight stainless-steel housing (1.4305)
A5S1-n-Manual_EN_Rev02
Standard(s)
EN IEC 60079-0
EN IEC 60079-15
EN 61326-1, EN IEC 61326-3-2
EN 61010-1
EN IEC 63000
2
2
, resp. 4x0.5 mm
with R < 36 Ohm/km and C <
2021_JAN_19
range.
Page 33 of 36