TROUBLESHOOTING GUIDELINES
These guidelines should be utilized by a qualified service
agent.
RESETTING THE HEATER CONTROL
•
Soft lockouts as diagnosed by the system error codes
require the gas control to be reset.
•
To reset the control, slide the "ON/OFF" switch to the
"OFF" position. Wait for 10 seconds and move the
switch back to the "ON" position.
•
If the problem that caused the control to lock out has
not been corrected, the control will remain or again go
back into lockout.
LOCKOUTS
Soft Lockout
•
Occurs when a system safety device trips to break the
sequence of operation. The control will try to start the
system in a timed basis but will not reinstate operation
until the failure is corrected.
Hard Lockout
•
Occurs when the main controller fails and must be
replaced.
54
IGNITION STATE AND TIMING
IGNITION STATE
5 seconds (NG models)
Pre-purge
15 seconds (LP models)
Hot Surface Igniter
10 seconds
(HSI) Warmup
Ignition Activation
3.5 seconds maximum
Period (IAP)
Flame Recognition
0.5 second
Period (FRP)
Trial For Ignition
IAP + FRP
Flame Stabilization
Not Applicable
Period
Inter-purge
30 seconds
Flame Failure
2 seconds max
Response Time
(@ 1uA flame current)
Post-purge
30 seconds
Pressure Switch (PS)
2 minutes
Prove Period
Pressure Switch (PS)
Fault Delay (failed
2 minutes
open/closed)
Soft Lockout
20 minutes
Energy Cut Off
Indefinite
(ECO) Limit Lockout
TIMING