Installing and Removing Power Components
DETAILED STEPS
Step 1
Attach the ESD-preventive wrist strap to your wrist and connect its leash to one of the ESD connection sockets on the
front (PLIM) side of the chassis or a bare metal surface on the chassis.
Step 2
While facing the front (PLIM) side of the chassis, pull the power tab on the bottom front of the module out to the OFF
position.
Step 3
Press the ejector lever release button at the top of the module to release the ejector lever.
Step 4
Pivot the ejector lever away from the module faceplate to eject the module from the power shelf backplane connector.
Pulling out the ejector lever not only physically ejects the module from the power shelf backplane connector,
Note
but also toggles an internal microswitch, shutting off power within the module.
Step 5
Grasp the module handle and pull the module halfway from the bay. Be sure not to pull the module by the ejector lever
but rather by the handle only.
A module weighs about 19 lb (8.6 kg). Because of the weight of the module and the elevated position of the
Caution
power shelf, you should use two hands when handling the module. It is safer to use two people and a ladder to
install or remove the module rather than a single person.
Step 6
Be sure to support the module while you slide the module completely from the bay, then set the module carefully aside.
What to do next
After performing this task, install a replacement AC rectifier or DC PEM if necessary (see Installing an AC
Rectifier or DC PEM, page 2-29) and replace the upper grille on the front (PLIM) side of the chassis.

Installing a Fixed Configuration Alarm Module

This section describes how to install an alarm module in a fixed configuration power supply in the LCC. An
alarm module can be installed only in the far right slot of the power shelf (as you are facing the front [PLIM]
side of the chassis).
Each AC or DC power shelf contains an alarm module, which monitors the status of the power shelf and
provides an external interface for system alarms. A dedicated alarm module slot exists on the right side of
every power shelf. The same alarm module is used in all power shelves.