CONDENSATE REMOVAL PUMP
MODEL: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS, CP654ULHTS
RULES FOR SAFE OPERATION
1.
Carefully read the Owners Manual and rules for safe operation.
2.
All wiring must conform to local codes. Use the National Electric Code if
local code is nonexistent.
3.
CAUTION! To reduce risk of electric shock disconnect from power supply
before servicing, pull the plug on models which have plug-in connections.
4.
Do not handle the pump with wet hands or when standing in water as fatal
shock could occur. Disconnect main power before handling unit for ANY
REASON!
5.
Protect the power cable from coming in contact with sharp objects.
6.
Do not kink power cable and never allow the cable to come in contact with
oil, grease, hot surfaces or chemicals.
7.
Make certain that line voltage conforms to the voltage specified on motor
and nameplate.
8.
WARNING! To reduce risk of electrical shock, connect only to a properly
grounded grounding type receptacle.
Select a location for the pump. It should be
as near as possible to the air conditioning
coil but avoid any water spray or drops on or
near the motor and switch cover. The pump
must be level. The inlet hole must be below
the coil drain.
Carefully unpack the pump. Remove the
switch cover. Check each float rod for "free"
action.
Run a drain line from the evaporator
coil drain to the pump. Use the flexible
plastic pipe where the code permits.
Insert the pipe 1" below the pump
cover. Do not install inlet drain line that
would interfere with operation of floats.
Connect outlet tubing (copper or vinyl)
to discharge on pump. Do not run
tubing vertical more than is
recommended by the lift on each unit.
For good flow, slant the horizontal run
downward toward the drain. Each unit
comes standard with a check valve for
connecting to ½" O.D. copper tubing. A
copper tube adapter is included for vinyl
hose hook-up.
Read and Follow all Safety Instructions.
Save This Manual for Future Reference.
INSTALLATION
COVER
PRIMARY SWITCH
FLOAT
PIPING
Copper Tube
Nut
Inner Ring
Check Valve
Ball-Cage
Snap Ring
Ball
Adapter
TERMINAL BLOCK
OUTLET
STAND
Designated
Pump Lift
SAFETY SWITCH
MOTOR
INLET
TANK
Vinyl Hose
Evaporator
("A" Coil)
92318_RevC

Advertisement

loading

Summary of Contents for Beckett CB501ULHTS

  • Page 1 CONDENSATE REMOVAL PUMP MODEL: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS, CP654ULHTS RULES FOR SAFE OPERATION Carefully read the Owners Manual and rules for safe operation. All wiring must conform to local codes. Use the National Electric Code if local code is nonexistent.
  • Page 2 If products are damaged in transit, a claim should be filed with the carrier. REMEDY: If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair, replace or issue a credit or refund for the particular nonconforming product or part.
  • Page 3 BOMBA PARA REMOVER CONDENSACION MODELO: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS y CP654ULHTS NORMAS PARA OPERACIÓN SEGURA Lea cuidadosamente el Manual del Usuario y las reglas para operación segura. Si no sigue las reglas de operación segura y las instrucciones, podría causar lesiones personales o daños a propiedad.
  • Page 4 Si el producto se daña en transito, cualquier queja o demanda deber ser presentada con el transportista. REMEDIOS: Si ha existido una falta en la garantía, Beckett, bajo su propia discreción, optará por reparar, reemplazar, o generar un crédito o reembolso para la parte en particular disconforme.

This manual is also suitable for:

Cb502ulhtsCb504ulhtsCp651ulhtsCp654ulhts