Siemens SIMATIC NET SFP Series Operating Instructions Manual

Siemens SIMATIC NET SFP Series Operating Instructions Manual

Network components
Hide thumbs Also See for SIMATIC NET SFP Series:

Advertisement

Quick Links

SIMATIC NET
Network components
Transceiver SFP/SFP+/SCP/STP
Operating Instructions
10/2019
A5E02630804-13
Introduction
Safety notes
Description of the device
Assembling
Uninstalling
Connecting up
Technical data
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SFP Series

  • Page 1 Introduction Safety notes Description of the device SIMATIC NET Assembling Network components Transceiver SFP/SFP+/SCP/STP Uninstalling Connecting up Operating Instructions Technical data Dimension drawings Approvals 10/2019 A5E02630804-13...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction..............................5 Safety notes..............................9 Description of the device ..........................11 Product overview........................12 Components of the product....................15 Assembling ..............................17 Safety notices for installation ....................17 Notes on installation of SFP / SFP+ transceivers ..............18 Using a pluggable transceiver (SFP/SFP+) ................21 Notes on installation of SCP / STP transceivers ..............22 Using a pluggable transceiver (SCP/STP) ................23 Uninstalling ..............................25 Removing a pluggable transceiver (SFP/SFP+) ..............25...
  • Page 4 Table of contents 7.3.1 SFP993-1 ..........................37 7.3.2 SFP993-1LD ..........................38 7.3.3 SFP993-1LH ..........................38 SCP transceiver ........................39 7.4.1 SCP992-1..........................39 7.4.2 SCP992-1LD ..........................39 STP transceiver........................40 7.5.1 STP991-1 ..........................40 7.5.2 STP991-1LD ..........................41 Attenuators..........................41 Construction ...........................42 Environmental conditions .......................42 Effective power loss .......................42 7.10 MTBF (Mean Time Between Failure) ..................43 Dimension drawings ...........................45 SFP dimension drawing ......................45 SFP+ dimension drawing .......................46...
  • Page 5: Introduction

    ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support: – Industrial Ethernet / PROFINET Industrial Ethernet System Manual (https:// support.industry.siemens.com/cs/ww/es/view/27069465)
  • Page 6 Feed under https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
  • Page 7 Introduction Device defective If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
  • Page 8 Introduction Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 9: Safety Notes

    Safety notes Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
  • Page 10 Safety notes Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 11: Description Of The Device

    Description of the device Structure of the type designation The type designation of an pluggable transceiver is made up of several parts that have the following meaning: Standard version (C) Conformal coating Interface Number of ports 1 100 Mbps 2 1000 Mbps 3 10 Gbps SF Pluggable transceiver with LC connector SC Pluggable transceiver with SC connector...
  • Page 12: Product Overview

    Description of the device 3.1 Product overview Interface *) Property 1000 Mbps, LC port optical, glass FO cable (single mode), up to max. 120 km ELH200 100 Mbps, LC port optical, glass FO cable (single mode), up to max. 200 km LD (Long Distance), LH (Long Haul), LH+ (Long Haul +), ELH (Extreme Long Haul) Product overview All plug-in transceivers listed below are intended for use in SIMATIC NET devices.
  • Page 13 Description of the device 3.1 Product overview Type Property Article number SFP992-1LD 1 x 1000 Mbps LC port optical for glass FO cable 6GK5 992-1AM00-8AA0 (single mode) up to max. 10 km 10 packing unit (VPE 10) 6GK5 992-1AM00-8AC0 SFP992-1LD (C) 1 x 1000 Mbps LC port optical for glass FO cable 6GK5 992-1AM00-8FA0 (single mode) up to max.
  • Page 14 Description of the device 3.1 Product overview SFP+ transceiver Type Properties Article number SFP993-1 1 x 10 Gbps, LC port optical for glass FO cable 6GK5 993-1AT00-8AA0 (multimode), up to max. 550 m SFP993-1LD 1 x 10 Gbps, LC port optical for glass FO cable 6GK5 993-1AU00-8AA0 (single mode), up to max.
  • Page 15: Components Of The Product

    Description of the device 3.2 Components of the product Media modules Note The SFP media modules MM992-2SFP may only be fitted with approved transceivers. The media module can be fitted with up to two pluggable transceivers. The SFP media modules MM992-4SFP may only be fitted with approved transceivers. The media module can be fitted with up to four pluggable transceivers.
  • Page 16 Description of the device 3.2 Components of the product Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 17: Assembling

    Assembling Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1, Division 2 or Zone 2. WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
  • Page 18: Notes On Installation Of Sfp / Sfp+ Transceivers

    Only use plug-in transceivers in approved SCALANCE devices Only use the SFP/SFP+ plug-in transceivers in SCALANCE devices that have ATEX/IECEx approval. If you use the SFP/SFP+ plug-in transceivers in other devices, Siemens cannot guarantee the compatibility and risk-free use of these components. Transceiver SFP/SFP+/SCP/STP...
  • Page 19 ● The use of transceivers of the types LH, LH+ or ELH. NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SFP / SFP+ transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 20 Note Plugging and pulling during operation With SCALANCE X, the pluggable transceivers can be plugged and pulled during operation. If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Notes on SCALANCE X-300...
  • Page 21: Using A Pluggable Transceiver (Sfp/Sfp+)

    Notes on SCALANCE W: Note With a SCALANCE W786-2, do not plug or pull an SFP transceiver during operation! If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Using a pluggable transceiver (SFP/SFP+)
  • Page 22: Notes On Installation Of Scp / Stp Transceivers

    General notes on pluggable transceivers NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SCP / STP transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 23: Using A Pluggable Transceiver (Scp/Stp)

    Notes on SCALANCE W: Note With a SCALANCE W786-2, do not plug or pull an SFP transceiver during operation! If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Using a pluggable transceiver (SCP/STP)
  • Page 24 Assembling 4.5 Using a pluggable transceiver (SCP/STP) Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 25: Uninstalling

    Uninstalling Removing a pluggable transceiver (SFP/SFP+) Notes on deinstallation CAUTION Risk of burns due to the high temperatures of the pluggable transceiver The pluggable transceivers can be plugged and pulled during operation. Leave the transceiver to cool down as much as possible. Procedure Follow the steps below to remove a pluggable transceiver: 1.
  • Page 26 Uninstalling 5.2 Removing a pluggable transceiver (SCP/STP) Procedure Figure 5-1 Removing a pluggable transceiver Follow the steps below to remove a pluggable transceiver: 1. Remove the connecting cable of the pluggable transceiver. 2. Press the spring in the transceiver slot to the right using a screwdriver, see figure. The transceiver is pushed part of the way out of the transceiver slot.
  • Page 27: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present.
  • Page 28: Power Supply

    Connecting up 6.2 Power supply NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Take the following precautions to avoid functional impairments: ●...
  • Page 29: Technical Data

    Technical data Note Deviations of the technical specifications from the values displayed in the WBM The values displayed can vary from the values displayed in the WBM (menu "System > Port diagnostics", "SFP diagnostics" tab). The values stated and explained in this document are authoritative.
  • Page 30: Sfp991-1Ld/Sfp991-1Ld(C)

    Technical data 7.1 SFP transceiver *) Depending on the cable used: ● If you are using at least OM1 fibers (attenuation ≤ 1.5 dB/km, bandwidth length product ≥ 500 MHz*km), you can reach a cable length of up to 3 km. ●...
  • Page 31: Sfp991-1Elh200

    Technical data 7.1 SFP transceiver Properties Receiver input Sensitivity min. -34 dBm Input power max. -10 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
  • Page 32: Sfp992-1

    Technical data 7.1 SFP transceiver Properties Receiver input Sensitivity min. -17 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
  • Page 33: Sfp992-1Ld

    Technical data 7.1 SFP transceiver Properties Receiver input Sensitivity min. -19 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
  • Page 34: Sfp992-1Lh

    Technical data 7.1 SFP transceiver 7.1.10 SFP992-1LH+ Properties Transmission mode 1000Base-ZX complying with IEEE 802.3 Transmission rate 1000 Mbps (Gigabit Ethernet) Transmission medium Single mode fiber-optic cable Light source Class1-LASER "Eye safe" Wavelength 1550 nm Cable length (max.) * 70 km Transmitter output (optical) Minimum 0 dBm...
  • Page 35: Bidirectional Plug-In Transceiver Sfp

    Technical data 7.2 Bidirectional plug-in transceiver SFP Bidirectional plug-in transceiver SFP LC connector technology (bidirectional) The attachment to Industrial Ethernet uses LC connector technology (Lucent Connector) with a fiber connection. Pluggable transceiver slot/ plugged in transceiver 7.2.1 SFP992-1BXMT Properties Transmission mode 1000Base-BX Transmission rate 1000 Mbps (Gigabit Ethernet)
  • Page 36: Sfp992-1Bx10T

    Technical data 7.2 Bidirectional plug-in transceiver SFP Properties Transmitter output (optical) Minimum -10 dBm Maximum -4 dBm Receiver input Sensitivity min. -17 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components"...
  • Page 37: Sfp+ Transceiver

    Technical data 7.3 SFP+ transceiver Properties Receiver input Sensitivity min. -21 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
  • Page 38: Sfp993-1Ld

    Technical data 7.3 SFP+ transceiver 7.3.2 SFP993-1LD Properties Transmission mode 10GBASE-LR complying with IEEE 802.3 Transmission rate 10 Gbps (10 Gigabit Ethernet) Transmission medium Single mode fiber-optic cable Light source Class1-LASER "Eye safe" Wavelength 1310 nm Cable length (max.) * 10 km Transmitter output (optical) Minimum...
  • Page 39: Scp Transceiver

    Technical data 7.4 SCP transceiver SCP transceiver SC connectors The attachment to Industrial Ethernet uses SC connector technology (Subscriber Connector). 7.4.1 SCP992-1 Properties Transmission mode 1000Base-SX complying with IEEE 802.3 Transmission rate 1000 Mbps (Gigabit Ethernet) Transmission medium Multimode fiber-optic cable Light source Class1-LASER "Eye safe"...
  • Page 40: Stp Transceiver

    Technical data 7.5 STP transceiver Properties Receiver input Sensitivity min. -19 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
  • Page 41: Stp991-1Ld

    Technical data 7.6 Attenuators 7.5.2 STP991-1LD Properties Transmission mode 100Base-LX complying with IEEE 802.3 Transmission rate 100 Mbps (Fast Ethernet) Transmission medium Single mode fiber-optic cable Light source Class1-LASER "Eye safe" Wavelength 1310 nm Cable length (max.) * 26 km Transmitter output (optical) Minimum -15 dBm...
  • Page 42: Construction

    Technical data 7.9 Effective power loss Construction Construction SFP/SFP+ Dimensions (W x H x D) 14 x 9 x 57 mm Weight 20 g SCP/STP Dimensions (W x H x D) 28 x 9 x 57 mm Weight 60 g Environmental conditions Environmental conditions Transportation/storage temper‐...
  • Page 43: Mtbf (Mean Time Between Failure)

    Technical data 7.10 MTBF (Mean Time Between Failure) Effective power loss at 25 °C ambient temperature SFP+ SFP993-1 0.67 W SFP993-1LD 0.85 W SFP993-1LH 1.4 W SCP992-1 0.33 W SCP992-1LD 0.41 W STP991-1 0.36 W STP991-1LD 0.39 W Note Fusing of transceivers The pluggable transceivers (SFP/SFP+/SCP/STP) do not have fuses.
  • Page 44 Technical data 7.10 MTBF (Mean Time Between Failure) MTBF SCP992-1 > 670 years SCP992-1LD > 600 years STP991-1 > 490 years STP991-1LD > 490 years Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 45: Dimension Drawings

    Dimension drawings SFP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 46: Sfp+ Dimension Drawing

    Dimension drawings 8.2 SFP+ dimension drawing SFP+ dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 47: Scp Dimension Drawing

    Dimension drawings 8.3 SCP dimension drawing SCP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 48: Stp Dimension Drawing

    Dimension drawings 8.4 STP dimension drawing STP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 49: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 50 ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15273/cert) The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014/34/EU "Equipment and Protective Devices for Use in Potentially...
  • Page 51 Approvals Permitted types of protection The following types of protection are possible: ● nA ATEX classification: II 3G Ex nA IIC Gc Certificate no.: DEKRA 18ATEX0078 U The products meet the requirements of the following standards: – EN 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 52 Approvals The following types of protection are possible: ● nA IECEx classification: Ex nA IIC Gc Certificate no.: DEK 18.0050 U The products meet the requirements of the following standards: – IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 53 Approvals Applied standards: ● EN 61000‑6‑2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments ● EN 61000‑6‑4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments You will find the current versions of the standards in the currently valid EC declaration of conformity.
  • Page 54 ● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) ● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) ● "EMC Installation Guidelines" configuration manual (https://support.industry.siemens.com/...
  • Page 55 Approvals WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above.
  • Page 56 Approvals Transceiver SFP/SFP+/SCP/STP Operating Instructions, 10/2019, A5E02630804-13...
  • Page 57: Index

    Index STP transceiver, 14 System manual, 5, 54 Approvals, 49 Article number, 15 Attenuation, 41 Type designation, 11 Attenuator, 41 CE mark, 49 Components of the product, 15 Fiber monitoring, 12 Pluggable transceiver Inserting, 21, 23 Notes on deinstallation, 25 Removing, 25, 26 SCP, 14 SFP, 12...