7.6 Set values for monitoring the winding temperature

7.6
Set values for monitoring the winding temperature
Prior to commissioning
Before running the machine for the first time, set the temperature value for shutdown on the
monitoring device.
Table 7-3
Set value
Shutdown
Normal operation
Measure the normal operating temperature T
for shutdown and warning according to the operating temperature T
depend on the design of the insulation system or the temperature class of the machine. The
data can be found on the rating plate.
Table 7-4
Set value
Warning
Shutdown
7.7

Test run

After installation or inspection, carry out a test run:
1. Start up the machine without a load. To do this, close the circuit breaker and do not switch
2. If the machine is running smoothly and evenly, switch on the cooling equipment. Continue
86
Set values for monitoring the winding temperatures during commissioning
Set values for monitoring the winding temperatures in normal operation
off prematurely. Check whether it is running smoothly.
Switching the machine off again while it is starting up and still running at slow speed should
be kept to a bare minimum, for example for checking the direction of rotation or for checking
in general.
Allow the machine to run down before switching it on again.
to observe the machine for a while in no-load operation.
Temperature
at the installation site in °C. Set the values
operation
Insulation class 155(F)
T
+ 10 K ≤ 145 °C
op
T
+ 15 K ≤ 155 °C
op
145 °C
. The set values
operation
Insulation class 180(H)
T
+ 10 K ≤ 170 °C
op
T
+ 15 K ≤ 180 °C
op
SIMOTICS TN Series N-compact 1LL8