Water Flow Sensor - Bosch T2400S 8 ND 23 Training And Service Information For After Sales

Room sealed fan assisted / pressurized gas water heater for indoor installation
Table of Contents

Advertisement

4.10

Water Flow Sensor

Water flow is measured by a turbine flow sensor that is fed by a DC signal of 5 V, and
gives a proportional feedback to the measured water flow.
-
Flow rate to operate the appliance: 2.8 l/min
-
Flow rate to shut off the appliance: 2.4 l/min
Water flow characteristic curve formula: f = 6.9 x Q
Note:
f is output frequency (Hz)
Q is water flow rate (L/min)
In case Q > 2.8l/min following P
- If P
> Minimum Power, the appliance will run with the calculated minimum water
out
flow, in order to reach the set point with a temperature stability of + / - 1ºC;
Page 19 from 45
Flow (L/min)
Frequency (Hz)
15
103.5
14
96.6
13
89.7
12
82.8
11
75.9
10
69
9
62.1
8
55.2
7
48.3
6
41.4
5
34.5
4
27.6
3
20.7
2
13.8
Table 8 – Water flow sensor values
Pict.27 –Water Flow Sensor
verification occurs:
out
6 720 887 546 "SM FP_ErP LPP-MPP Europe 2018/05 en"