2. INSTALLATION

2.1. SITING THE MACHINE

Site the machine on a stationary, horizontal, dry and clean base from which there does not come any dust etc. into
inlet air through the rear grate.
Ensure free circulation of the cooling air.
Degree of protection IP23C of the machine allows at its maximum the water jet coming in 60° angle to hit machine´s
outer covering. See to that the machine is positioned away from the line of the particle spray, created by grinding
tools etc.
max. 15°

2.2. CONNECTION TO THE MAINS SUPPLY

Connection and change of the mains cable and the plug must be carried out only by a competent
electrician. Remove for the mounting of the mains cable the left side plate, seen from the front of the
power source.
The Kempoweld power source is equipped with 5 m supply cable without plug. The mains cable is according to
the marking H07RN-F of the norm CENELEC HD22.The mains cable must be changed if it does not meet local
regulations.
Mounting of the mains cable
05
Sizes of mains cables and fuse ratings for the machine at 100% ED duty cycle are specified
in the table below:
Kempoweld 3200, 3200W
Connected voltage
230 V
Voltage range
220...240 V
Fuses, delayed
20 A
Connected cable
4 x 2.5 S mm²
In cables of S type there is protective grounding conductor coloured green-yellow.
This equipment's electromagnetic compatibility (EMC) is designed for use in an industrial environment.
Class A equipment is not intended for use in residential location where the electrical power is provided
by the public low-voltage supply system.
6 – KEMPOWELD 3200, 3200W / 0543
rain water
60°
– See to that in front of the machine as well as at
the rear of the machine there is at least 20 cm free
distance to allow good circulation of the cooling
air through the machine.
– Protect the machine against heavy rain and in
circumstances over 25°C against direct sunshine
The cable is entered into the machine through the inlet ring on the
rear wall of the machine and locked with a cable clamp (05).
The phase conductors of the cable are coupled to connectors L1,
L2 and L3. The earth protection coloured green-yellow is coupled
to connector marked with earth protection symbol
using 5-conductor cable, you must cut the zero conductor to the
level of the cable´s protective shield.
400 V
380...415 V
16 A
4 x 2.5 S mm²
. If you are