Panasonic DMR-EX77EG Service Manual page 22

Table of Contents

Advertisement

DMR-EX77EG / DMR-EX77EC / DMR-EX77EC1 / DMR-EX77EB / DMR-EX87EG / DMR-EX87EC / DMR-EX87EC1 / DMR-EX87EB
Mode name
HDD
READ
VERIFY
Inspection
HDD Spin-up time
Item
Description
Measure of access time in READ VERIFY
MODE of HDD.
The accumulation value of the Spin-up time of
HDD is displayed.
FL display
At start
The [*] sign is added every 20
seconds while inspecting.
Two digits on the right side are the
progress level of the inspection
(The unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o )
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.
)
$: [X] is displayed when seek time is
over 270msec., there is error or
transfer rate is NG.
Position
at
$
is
space
excluding those.
##:
Number
of
data
of
100msec. and less than 270msec.
When it is over 100, [99] is
displayed.
When the number is less than 5, we
judge it normal.
Spin-up time of HDD is displayed.
(The unit of display is hour.)
22
Key operation
(Remote controller key)
Press [3] [2] in service mode.
* When canceling the inspection
mode while executing, do "forced
power-off".
Method:
Press [POWER] key more than 10
seconds.
when
over
Press [3] [3] in service mode.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents