Panasonic HIT VBHN330SA16 Installation Manual

Panasonic HIT VBHN330SA16 Installation Manual

Hit vbhnxxxsa16 series photovoltaic module
Hide thumbs Also See for HIT VBHN330SA16:

Advertisement

Quick Links

General Installation Manual
VBHNxxxSA16 series
Thank you for choosing Panasonic HIT
Please read this manual completely
before installation or use of Panasonic
PV(photovoltaic) modules. With proper
operation and maintenance, Panasonic
®
HIT
will
provide
you
renewable solar electricity for many
years. This manual contains important
installation, maintenance and safety
information. The word "module" as
used in this manual refers to one or
more PV modules. Retain this manual
for future reference. The module is
considered to be in compliance with UL
1703 only when the module is mounted
in
the
manner
specified
mounting instructions below.
SANYO is part of the Panasonic Group
and is in charge of the manufacturing
process for Panasonic HIT
VBHNxxxSA16 series
®
Model No.
VBHN330SA16 and 16B
VBHN325SA16 and 16B
®
.
with
clean,
by
the
®
.
Contents
Please read before installation
 Note on Specifications
"HIT" is a registered trademark of
Panasonic Group.
Other product and service names listed
in
registered
respective companies.
1
this
manual
are
trademarks
trademarks
of
:3
:3
:3
:3
:3
:3
:3
:4
:5
:5
:5
:5
:5
:5
:5
:5
:6
:6
:7
:7
:7
:7
:7
:7
:7
or
their

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic HIT VBHN330SA16

  • Page 1: Table Of Contents

     Module Wiring mounting instructions below.  Array Wiring  Earth Ground Wiring SANYO is part of the Panasonic Group  Grounding Locations and is in charge of the manufacturing  Grounding Methods ® process for Panasonic HIT ...
  • Page 2 Revision Edition Revised Item Revised Content Date New Edition 2016.2.10 ・ Change from connection box to connection Edition 2016.3.17 Name change devices ・Change from ambient to operating Edition 2016.4.20 Changing installation condition ・ Clearance between the roof surface and the module ・Add the figures and requirement specification of ・Addition of figures of clamps...
  • Page 3: Photovoltaic Module Hit

     Please read this guide completely before Do not treat the back sheet, frame, or connected in series, producing higher installing or using your Panasonic PV modules. front surface with paint or adhesives, to voltages. avoid reducing its’ functionality, damage, This section contains important electrical and ...
  • Page 4: Operating Conditions :4

    Stainless steel, End clamp; 5000 & 6000 Aluminum alloys  Note: Please refer IronRidge manual, for installation method.  Panasonic does not provide a warranty Mid clamp clamps. module warranty End clamp voided if Panasonic provides shall be <Ironridge clamps>...
  • Page 5: Special Conditions :5

     Check local codes for requirements.  Wiring methods should be in accordance time of shipment, Panasonic guarantees with the NEC in USA or CEC in Canada. the output level of its modules to be - Earth Ground Wiring ...
  • Page 6: Grounding Locations :6

    Lay-in lugs or grounding clips can be used bolt and nut is 2.3 N.m (20in-lb). Method- Use a bolt and nut (see Figures 3.1 to ground Panasonic PV modules. Both and 3.2) methods are explained below, please Using a Grounding Clip with bolt and nut ...
  • Page 7: Module Terminations :7

    (see Figure maintain optimal output performance of Contact Information 4.2). the solar modules.  Each terminal is provided with factory Panasonic Eco Solutions of North America  It is also recommended to inspect the installed lead cables latching Two Riverfront Plaza.
  • Page 8 Table.1 Approved connectors list Manufacturer Model # Contact Information PV-KST4, PV-KBT4 followed by /2.5 or /6, followed by "I" or "II", followed by -UR. or - may be followed by additional suffixes, may be followed by suffix numbers and letters. PV-PLS-S, PV-PLS-B, may be followed by suffix numbers and letters, Multi-Contact AG may be followed by suffix numbers and letters.
  • Page 9 Figure 3.2 (Method 1) Glass Grounding method using bolt and nut Backsheet Frame (Longer side) Note: ground holes illustrated in Figure 3.1. Nut (Stainless steel) Flat washer (Stainless steel) *If using a brass cup washer, a Star washer (Stainless steel) flat washer must be inserted Grounding hole between the cup washer and...
  • Page 10 Figure 3.4 Grounding method Glass Frame (Longer side) Using Grounding Clip with bolt and nut Backsheet Note: ground holes illustrated in Figure 3.1. Grounding hole Grounding Clip Assemblies: Tyco (0.205” diameter (5.2mm)) Electronics 1954381-2 8-32 Screw (Stainless steel) Length (not less than 0.63’‘(16 mm) not more than 0.78’‘(20 mm)) Nut (Stainless steel) Copper wire...
  • Page 11 SPECIFICATIONS Electrical Specifications Model VBHN330SA16 VBHN325SA16 VBHN330SA16B VBHN325SA16B Cell Number in Series Rated Power, Watts (Pmax) Maximum Power Voltage (Vpm) 58.0 57.6 Maximum Power Current (Ipm) 5.70 5.65 Open Circuit Voltage (Voc) 69.7 69.6 Short Circuit Current (Isc) 6.07 6.03 Cell Type Silicon hetero-junction* Silicon hetero-junction* Maximum System Voltage...

This manual is also suitable for:

Hit vbhn330sa16bHit vbhn325sa16Hit vbhn325sa16b

Table of Contents