Flushing the Cooling System (Powerhead)

Flush the internal water passages of the engine with fresh water after each use
in salt, polluted, or muddy water. This will help prevent a buildup of deposits
from clogging the internal water passages.
a
a -
Plug located on fitting
b -
Water hose
1. Remove the plug from fitting in the bottom cowl.
2. Attach a water hose to the fitting. Turn on the water and flush for three to
five minutes.
NOTE: The engine can be stopped or operated at idle speed when flushing the
cooling system. Do not flush engine using a water system that exceeds
310 kPa (45 psi).