Electrical Adjustments; Cd Section - Sony RCD-W50C Service Manual

Hide thumbs Also See for RCD-W50C:
Table of Contents

Advertisement

RCD-W50C
CD SECTION (DECK A)
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10MΩ impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S Curve Check
Connection :
BD board
TP (FE)
TP (DVC)
Procedure :
1. Connect an oscilloscope to test point TP (FE) and TP (DVC) on
the BD board.
2. Turn the power on.
3. Load the disc (YEDS-18).
4. Enter the test mode, select the BU Test asd press the l
AMS L (DECK B) knob to display "bdt S CURVE".
5. Press the l AMS L (DECK B) knob. "LD AL" is
displayed and playback starts automatically.
6. Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 3.6 ±
0.5 Vp-p.
7. Press the MENU/NO button to stop playback.
8. Exit from the test mode.
(Refer to the TEST MODE Section)
VOLT/DIV : 1V
TIME/DIV : 2ms
Note: Try to measure several times to make sure than the ratio of A
: B or B : A is more than 10 : 7.
RF Level Check
Connection :
BD board
TP (RFAC)
TP (DVC)
Procedure :
1. Connect an oscilloscope to TP (RFAC) and TP (DVC).
2. Turn the power on.
3. Load the disc (YEDS-18) and playback the number five track.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
24
SECTION 5

ELECTRICAL ADJUSTMENTS

oscilloscope
(DC range)
+
symmetry
A
within 3.6 ± 0.5 Vp-p
B
oscilloscope
(AC range)
+
Note: A clear RF signal waveform means that the shape "◊" can be
clearly distinguished at the center of the waveform.
E-F Balance (1 Track jump) Check
Connection :
BD board
TP (TE)
TP (DVC)
Procedure:
1.
Connect an oscilloscope to TP (TE) and TP (DVC).
2.
Turn the power on.
3.
Load the disc (YEDS-18) and playback the number five track.
4.
Press the X (DECK A) button.
(Becomes the 1 track jump mode.)
5.
Confirm the level B and A (DC voltage) on the oscilloscope
waveform.
0V
level=1.1 ± 0.6Vp-p
A
x 100=less than ±22%
Specification level:
B
[BD BOARD] — SIDE A —
TP (DVC)
IC104
IC103
TP (RFAC)
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.1 ± 0.3Vp-p
oscilloscope
(DC range)
+
Center of
waveform
B
A (DC voltage)
Symmetry
TP (TE)
TP (FE)
IC101