Pentair IntelliFlo VS+ SVRS Installation And User Manual

Pentair IntelliFlo VS+ SVRS Installation And User Manual

Variable speed programmable pump with safety vacuum release system (svrs) protection
Table of Contents

Advertisement

Quick Links

with Safety Vacuum Release System (SVRS) Protection
(Compatible with IntelliComm
EasyTouch
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
IntelliFlo
®
, IntelliTouch
Variable Speed Programmable Pump
®
communication center,
®
and SunTouch
AUTO
HEATER
SPA
100 ° F/95 ° F
AIR
70 ° F
MON
09:30 AM
User's Guide
®
VS+ SVRS
®
control systems)
Installation
and

Advertisement

Table of Contents
loading

Summary of Contents for Pentair IntelliFlo VS+ SVRS

  • Page 1 ® IntelliFlo VS+ SVRS Variable Speed Programmable Pump with Safety Vacuum Release System (SVRS) Protection ® (Compatible with IntelliComm communication center, ® ® ® EasyTouch , IntelliTouch and SunTouch control systems) AUTO HEATER 100 ° F/95 ° F 70 ° F 09:30 AM Installation User’s Guide...
  • Page 2 Company Corporation. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.
  • Page 3: Table Of Contents

    Contents Warnings and Important Safety Precautions ............iIi Section 1: IntelliFlo VS+ SVRS Overview............1 IntelliFlo VS+ SVRS Variable Speed Pump .............. 1 Remote Control ....................1 Features ......................2 IntelliFlo Motor Assembly ..................3 IntelliFlo VS Motor Features ................. 4 Section 2: Operator Control Panel ..............
  • Page 4 Automatic pool sweeps (booster pump style) ............47 Filter during off-peak times ..................47 Setting filtering time ....................47 How to make your pool more energy efficient ............47 Preventive maintenance ..................48 Energy Efficient IntelliFlo VS pump ................48 IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 5: Warnings And Important Safety Precautions

    This information should be given to the owner and/or operator of this equipment. ® Please refer to www.pentair.com for all warnings and instructions related to the IntelliFlo VS+SVRS pump. Before installing this product, read and follow all warning notices and instructions which are included.
  • Page 6 (E) Disabled submerged outlets, or (F) Suction outlets shall be reconfigured into return inlets. For more information about the Act, contact the Consumer Product Safety Commission at 301 504 7908 or visit www.cpsc.gov. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 7 "SVRS" text is not displayed on the control panel screen, the SVRS feature is disabled. The IntelliFlo® VS+SVRS pump ("pump") has been designed to specifically operate with Pentair Water Pool and Spa control systems. Operating the pump with other manufacturers' controllers may cause software failure of the pump, drive or other system components. Such failure can result in severe personal injury (i.e., failure of the SVRS system, electrical shock)
  • Page 8 5 feet (1.52 m) away, adjacent to, and within sight of, the unit. When setting up pool water turnovers or flow rates the operator must consider local codes governing turnover as well as disinfectant feed ratios. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 9 For hot tubs and spa pumps, do not install within an outer enclosure or beneath the skirt of a hot tub or spa unless so marked. IntelliFlo VS+ SVRS is capable of generating systems pressures up to 50 psi. Installers must ensure that all system components are rated to withstand at least 50 psi. Over pressurizing the system can result in catastrophic component failure or property damage.
  • Page 10 Blank Page IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 11: Section 1: Intelliflo Vs+ Svrs Overview

    The IntelliFlo VS+ SVRS variable speed pump with the safety vacuum release system (SVRS) protection is well suited for all of your pool, spa, waterfall and other applications. The IntelliFlo VS+ SVRS can use up to eight (8) speeds which can be adjusted to run at specific speeds and time intervals. IntelliFlo out performs all conventional pumps in its class.
  • Page 12: Features

    Prevents thermal overload Detects and prevents damage from under and over voltage conditions Protects against freezing Communicates with a Pentair EasyTouch, IntelliTouch or SunTouch control system or IntelliComm communication center via a two-wire RS-485 cable connection Easy to use operator control panel...
  • Page 13: Intelliflo Motor Assembly

    Motor fan cover Motor assembly Drive assembly and electronics enclosure Control panel cover Communication port for connection to EasyTouch, IntelliTouch or SunTouch control system or IntelliComm communication center via two-wire RS-485 cable IntelliFlo Motor Assembly IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 14: Intelliflo Vs Motor Features

    Operates at lower temperatures due to high efficiency • Same technology as deployed in hybrid electric vehicles • Designed to withstand outdoor environment • Totally enclosed fan cooled • Three-phase motor • 56 Square Flange • Six-Pole • Low noise IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 15: Section 2: Operator Control Panel

    Section 2 Operator Control Panel This section describes the IntelliFlo VS+ SVRS operator controls and LEDs. IntelliFlo VS+ SVRS Operator Control Panel ® SVRS ENABLED when displayed (see page 13) SVRS FILTER 12:15 Current Time Key Lockout Icon 15.W 15.W...
  • Page 16 System time is displayed on the right side of top line. • Line 2 - Displays the current pump speed (RPM). • Line 3 - Count down time and Watts • Line 4 - Current pump status. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 17: Stopping The Pump

    Section 3 Operating IntelliFlo VS+ SVRS This section describes how to operate the IntelliFlo VS+ SVRS pump using the control panel buttons and menu features. Starting the pump To start the pump 1. Be sure the pump is powered on and the green power LED is on.
  • Page 18: Pump Operating Modes

    Pressing the Start/Stop button places it in the Running Schedule mode. Therefore, it will only run Speeds that are Scheduled to come on at their scheduled Start Time. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 19: Intelliflo Vs+ Svrs Menus

    ANTI FREEZE DISABLED/ENABLED (page 21) Set Speed (1100 RPM - 3450 RPM) Default 1100 RPM SET SPEED 40˚ F - 50˚ F (4.4˚ C - 10˚ C) Default: 40˚ F (4.4˚ C) PUMP TEMPERATURE IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 20: Settings: Pump Address

    6. Press Up or Down arrow button to set the time. 7. Press the Enter button to save the setting. To cancel any changes, press the Escape button to exit edit mode without saving. 8. Press the Escape button to exit. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 21: Settings: Set Am/Pm Or 24 Clock

    6. Press the Select button to change the setting. Number will highlight. 7. Press the Enter button to save the setting. To cancel any changes, press the Escape button to exit edit mode without saving. 8. Press the Escape button to exit. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 22: Settings: Language

    6. Press Up or Down arrow button to change the pump’s maximum speed setting from 1900 to 3450 RPM. 7. Press the Enter button to save the setting. Press the Escape button to exit. To cancel any changes, press the Escape button to exit edit mode without saving. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 23: Settings: Svrs Auto Restart

    SVRS alarm, a blockage alarm when there is no blockage present. It is always recommended to bleed the air off of the filter when starting the pump. Suction side air leaks in the system can contribute to false SVRS alarms. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 24: Settings: Password

    If any button other than the Start/Stop button is pressed, the screen reads Enter Password. • When Password Protection is enabled there is a key icon displayed in the upper left side of the LCD. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 25: Settings: Ramp Speed

    5. Press the Select button. The Default setting is 200 RPM. 6. Press the Left or Right arrow button to move cursor and press up and down arrow to change the setting. 7. Press Enter to save the setting. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 26 (8) different speeds at eight (8) programmed start and stop times per day. Note: When two speeds are scheduled during the same run time the pump will run the higher RPM Speed regardless of Speed # in use. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 27: External Control

    (LED on) to start the pump at preset RPM and duration of time. When the Quick Clean cycle is over it will resume regular schedules, it will be in the “Running Schedule” mode. 0 IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 28: Features: Time Out

    Time out can be set from 1 minute to 10 hours. 9. Press the Enter button to save the setting. Note: To cancel any changes, press the Escape button to exit without saving. 10. Press the Escape button to exit. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 29: Priming

    To access the Priming menu: 1. Check that the green power LED is on and press the Menu button. “Settings” is displayed. 2. Use the Down arrow button to scroll to “Priming” (continue on next page) IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 30 19. Press the Enter button to save the setting. Note: To cancel a change, press the Escape button instead of the Enter button to exit without saving. 20. Press the Escape button to exit. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 31: Antifreeze

    40° F to 50° F (4.4° C - 10° C). 14. Press the Enter button to save the setting. Note: To cancel any changes, press the Escape button to exit without saving. 15. Press the Escape button to exit. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 32: Priming The Pump For The First Time, Or After Service

    20 minutes before trying to work on it. The IntelliFlo VS provides an automatic internal cutoff switch to protect the motor from heat damage during operation. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 33: Priming The Pump

    11. Use the Up/Down button to adjust the operating speed as desired. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 34: External Control With Intellicomm Communication Center

    External Control with IntelliComm Communication Center The IntelliFlo VS+ SVRS can be remotely controlled by the Pentair Water Pool and Spa IntelliComm Communication Center using an optional RS-485 communications cable (P/N 350122). The IntelliComm provides four pairs of input terminal connections. These inputs are actuated by either 15 - 240 VAC or 15 - 100 VDC.
  • Page 35: Connecting Intelliflo Vs To An Easytouch System

    3. Remove the two retaining screws securing the high voltage cover panel, and remove it from the enclosure. 4. Loosen the two access screws securing the control panel. Control panel Control panel access screw access screw Retaining screw High voltage cover panel EasyTouch Load Center (front view) IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 36 9. Insert the screw terminal onto the EasyTouch COMPORT (J20) board connector. Note: Multiple wires may be inserted into a single screw terminal. EasyTouch COMPORT (J20) Indoor Control Panel IntelliChlor IntelliFlo RF Transceiver IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 37 12. Close the EasyTouch load center front door. Fasten the two spring latches. 13. Switch the power on to the EasyTouch load center. Control panel access screw Control panel access screw Retaining screw High voltage cover panel EasyTouch Load Center (front view) IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 38: Connecting Intelliflo Vs To An Intellitouch System

    5. Insert the two-wire cable into plastic grommet on the bottom of the enclosure and route the wire up through the low voltage raceway to the Personality board. Personality Board Access screw Low voltage raceway Cover-panel screw (Cover-panel not shown) Plastic grommet IntelliTouch Load Center IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 39 8. Install the high voltage cover panel and secure it with the two retaining screws. 9. Close the load center front door. Fasten the two spring latches. 10. Switch the power on to the load center. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 40: Connecting Intelliflo Vs To A Suntouch System

    IntelliFlo VS cable pin configuration SunTouch Motherboard HEATER SunTouch COM PORT (J11) screw terminal RESET CLNR CLNR COM PORT Pin configuration RS-485 communication cable (P/N 350122) IntelliFlo VS-3050 Drive 230 VAC Power to Pump IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 41: Section 4: User Maintenance

    8. Clean the cover, o-ring, and sealing surface of the pump pot. Grease ® the o-ring with Teflon or silicone lubricant. 9. Reinstall the lid by placing the clamp and the lid on the pot. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 42: Motor Service

    Note: DO NOT wrap motor and controller with plastic or other air tight materials. The motor and controller may be covered, but not wrapped in plastic, during a storm, for winter storage, etc., but never when operating, or expecting operation. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 43: Winterizing

    For instructions about how to prime the IntelliFlo VS pump, refer to “Priming the pump for the first time or after servicing,” on page 22. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 44 Blank Page IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 45: Section 5: Installation And Removal

    Note: Before installing this product, read and follow all warning notices and instructions on page iii- vi. IntelliFlo VS+ Kit Contents • IntelliFlo VS+ SVRS pump, RS-485 communication cable, FWC cover, gasket, screws, vacuum gauge, and Installation and User’s Guide (this manual). Installing the IntelliFlo VS Only a qualified service person should install the IntelliFlo VS pump.
  • Page 46: Wiring The Intelliflo Vs Pump

    2. If the system includes a filter, the filter must be in a clean condition prior to setting up the maximum flow condition. 3. Remove the drain plug from the pump strainer housing and install the vacuum gage into the 1/4" NPT housing opening. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 47: Pump Disassembly

    The screw is a left-handed thread and loosens in a clockwise direction. 8. Use a flat blade screwdriver to hold the motor shaft. The motor shaft has a slot on the end which is accessible through the center of the fan cover. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 48: Pump Reassembly/Seal Replacement

    Note: The polished and lapped faces of the seal could be damaged if not handled with care. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 49: Drive Assembly Removal And Installation

    5. Secure and tighten the drive assembly with the three Phillips head screws. Phillips head screw Phillips head screws Note: Do not remove these screws Adapter connector Gasket Orange motor post caps (QTY. 3) IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 50: Replacement Parts

    CLAMP CAM & RAMP WF (Almond) 072183 WASHER FLAT ¼ X 5/8 20 GA THICK 350621 CVR ASSY. INTELLIFLO VS FWC (Almond) 18-8 s/s (QTY 2) 355000 SVRS Suction Gauge (not shown) Note: (*) Not a serviceable part. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 51: Intelliflo Vs Flow And Power Vs Flow Pump Curve

    IntelliFlo VS Pump Dimensions IntelliFlo VS Flow and Power vs Flow Pump Curve IntelliFlo VS Electrical Specifications Circuit Protection: Two-pole 20 AMP device at the Electrical Panel. Input: 230 VAC, 50/60 Hz, 3200 Watts IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 52 Blank Page IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 53: Section 6: Troubleshooting

    (1) second. The second test method requires the use of a test mat to quickly cover the suction outlet to simulate an entrapment event. SVRS Blockage: WARNING ! When the pump is in PRIMING MODE, the SVRS feature is DISABLED. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 54: General Intelliflo Vs Troubleshooting Problems

    . t r r i f . y l c i l l l a P " " , s l IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 55 " . " v i t i t c y l l l i t IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 56: General Warnings

    The IntelliFlo VS cannot be matched in today’s industry for flow versus continuous watts at any speed by any other pump in pool. The Filter mode and flow control further assists in cost saving by always allowing the pump to do the least amount of work at all times. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 57: Using The Intelliflo Vs Pump

    Check your clock’s instruction manual for directions on setting the operation times. Remember to reset the time clock after power outages and for the fall and spring time change. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 58: Preventive Maintenance

    It moves more water more efficiently, and can help you reduce your filter operating time by hours. Once these tasks are done, IntelliFlo VS automatically ramps down to low speed for your pool's daily filtration cycle, which can save energy and money for you. IntelliFlo VS+ SVRS Installation and User’s Guide...
  • Page 59 Notes...
  • Page 60 *351017* P/N 351017 Rev. A...

Table of Contents