Toshiba RAS-M07SKV-E Service Manual page 65

Table of Contents

Advertisement

(For AC fan motor in RAS-M07, 10,13SKV-E, RAS-M10,13SKCV-E)
<Inspection procedure>
1. Remove the front panel. (Remove 2 screws.)
2. Remove the cover of the fan motor lead wires.
3. Check AC voltage with CN31 connector while the fan motor is rotating.
NOTE :
• Using a tester, measure the resistance value of each winding coil.
• Use a thin test rod.
AFS-220-20-4AR
• Do not disconnect the connector while the fan motor is rotating.
• For P.C. board side, proceed to the item "Only indoor fan does not oper-
ate" of "Judgment of Trouble by Every Symptom".
WHI
5
CN31
BLK
3
RED
1
BLU
3
CN33
PUR
2
GRY
1
P.C. board
Position (P.C. board)
Between
(Black) -
3
Between
(Black) -
3
Between
(Red) -
1
BLK
BLK
3
3
WHI
WHI
2
2
RED
RED
1
1
BLU
BLU
3
3
PUR
PUR
2
2
GRY
GRY
1
1
(Red)
1
(White)
5
(White)
5
Resistance value
74 ± 15 Ω
100 ± 20 Ω
174 ± 35 Ω
– 65 –
Revised-2