Led Indicators - Axis P3363–VE User Manual

Hide thumbs Also See for P3363–VE:
Table of Contents

Advertisement

AXIS P3363–VE Network Camera
Hardware Overview
NOTICE
NOTICE
NOTICE
The product shall be connected using a shielded network cable (STP). All cables connecting the product to the network switch
shall be shielded (STP) and intended for their specific use. Make sure that the network switch is properly grounded. For
information about regulatory requirements, see Regulatory Information, on page 2 .
Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker
with a built-in amplifier. A stereo connector must be used for audio out.
SD card slot - A standard or high-capacity SD card (not included) can be used for local recording with removable storage.
NOTICE
NOTICE
NOTICE
To prevent corruption of recordings, the SD card should be unmounted before removal. To unmount, go to Setup > System
Options > Storage > SD Card and click Unmount.
Control button - The control button is used for:
Resetting the product to factory default settings. See page 52.
Connecting to an AXIS Video Hosting System service. See page 45. To connect, press and hold the button for
about 1 second until the Status LED flashes green.
Connecting to AXIS Internet Dynamic DNS Service. See page 46. To connect, press and hold the button for
about 3 seconds.
I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications.
In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:
Digital output – For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The
output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
Digital input – An alarm input for connecting devices that can toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and
the input becomes active (shown under System Options > Ports & Devices).

LED Indicators

LED
Color
Network
Green
Amber
Unlit
Status
Green
Amber
Red
Power
Green
Amber
Indication
Steady for connection to a 100 MBit/s network. Flashes for network activity.
Steady for connection to a 10 MBit/s network. Flashes for network activity.
No network connection.
Steady green for normal operation.
Steady during startup and when restoring settings.
Slow flash for failed upgrade.
Normal operation.
Flashes green/amber during firmware upgrade.
7

Advertisement

Table of Contents
loading

Table of Contents