Test 7 Gas Valve Test - Gas Type - LG DLE0442W Service Manual

Hide thumbs Also See for DLE0442W:
Table of Contents

Advertisement

Test 7
GAS Valve test - Gas Type
Caution
Trouble Symptom
Measurement Condition
Valve 1
Igniter
Valve 2
When measuring power, be sure to wear insulated gloves, to avoid electric shock.
While operating, Heating will not work.
Drying time takes longer.
With dryer power on
Power On & Start (Normal Cycle)
When measuring Valve 1 voltage,
More than AC 90V?
Igniter operates?
(after 1 min, Igniter becomes reddish)
When measuring Valve 2 voltage, Value is more
than AC 90V? (10 sec after Igniter off)
When measuring terminal resistance on "Valve 1",
"Valve 2", Value is more than1.5 ~ 2.5kΩ?
(Measure after Off )
• Harness check
• Controller change
NO
YES
YES
NO
NO
23
• Check thermostat
NO
Hi limit Safety
• Check Igniter &
NO
Frame detect
• Check Gas
YES
connection or
Gas supply
• Change Valve
YES

Advertisement

Table of Contents
loading

Table of Contents