Wiring Diagram - DeWalt DXH210FAVT Instruction Manual

Forced air propane construction heater
Table of Contents

Advertisement

WARNING
When using a thermostat controlled heater, its exit area should be protected
from personnel and warnings posted of sudden startup.
RECOMMENDED MINIMUM GAUGE FOR CORD EXTENSIONS
Wire Gauge Chart A.W.G.
Name
Plate 120V
Amps.
25
5-6
18
6-8
18
8-12
18
10-12
16
12-14
16
210FAVT - WIRING CHART
COLOR
LENGTH
White
7"
Black
6"
Red-(Hi-Temp)
16 1/2"
Red-(Hi-Temp)
16 1/2"
Orange
11"
Green
7"
Red
7"
White
6"
Black
6"
Cord Length in Feet
50
100
150
16
14
12
16
12
10
14
12
10
14
10
8
12
10
8
FROM
TO
Valve
Terminal Block
On/Off Switch
Terminal Block
High Limit Switch
Valve
High Limit Switch
Terminal Block
Flame Control
Spark Plug
(Ignition)
Flame Control
Ground
(Harness)
Flame Control
Terminal Block
(Harness)
Flame Control
Terminal Block
(Harness)
Flame Control
Terminal Block
(Harness)
210FAVT - WIRING DIAGRAM
COLOR CODE
B-BLACK
Y-YELLOW
L-BLUE
R-RED
G-GREEN
W-WHITE
O-ORANGE
If any original wiring as supplied by the heater must be replaced, it must be
replaced with type AWG 105° C wire or its equivalent except as indicated
(*type SF2-200, **SGI 250° C).