Carrier N8MXL Installation Instructions Manual page 18

80% single stage, ecm motor category i, gas furnace
Table of Contents

Advertisement

Gray
Blue
Yellow
1352420
Orange
Red
1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in factory-authorized
accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
2. Adjust the blower speed tabs as necessary for the proper air temperature rise for each installation.
3. Highlighted areas indicate airflow range is beyond the range allowed for heating. THESE AIRFLOW RANGES MAY ONLY BE USED FOR COOLING.
4. -- Indicates unstable operating conditions.
NOMINAL IRON
PIPE
SIZE IN. (mm)
1/2 (13)
3/4 (19)
1 (25)
1-1/4 (32)
1-1/2 (38)
* Cubic ft. of natural gas per hr for gas pressures of 0.5 psig (14-In. W.C.) or less and a pressure drop of 0.5-In. W.C. (based on a 0.60 specific gravity
gas). Ref: Chapter 6 current edition of ANSI Z223/NFPA 54.
Piping should be pressure and leak tested in accordance with
NFGC in the United States, local, and national plumbing and gas
codes before the furnace has been connected. After all
connections have been made, purge lines and check for leakage at
furnace prior to operating furnace.
If pressure exceeds 0.5 psig (14−In. W.C.), gas supply pipe must
be disconnected from furnace and capped before and during
supply pipe pressure test. If test pressure is equal to or less than
0.5 psig (14−In. W.C.), turn off electric shutoff switch located on
furnace gas control valve and accessible manual equipment
shutoff valve before and during supply pipe pressure test. After
all connections have been made, purge lines and check for
leakage at furnace prior to operating furnace.
The gas supply pressure shall be within the maximum and
minimum inlet supply pressures marked on the rating plate with
the furnace burners ON and OFF.
18
5
2065
2005
4
1825
1760
3
1760
1690
2
1620
1550
3
1
1325
1260
Table 6 – Maximum Capacity of Pipe*
INTERNAL
DIAMETER
In. (mm)
0.622 (16)
0.824 (21)
360 (110)
1.049 (27)
680 (207)
1.380 (35)
1400 (427)
1.610 (41)
2100 (640)
Fig. 19 − Upflow Return Air Configurations and Restrictions
Specifications are subject to change without notice.
1940
1875
1810
1695
1630
1560
1625
1555
1485
1480
1405
1335
1185
1100
1025
LENGTH OF PIPE - FT. (M)
10
20
175 (53)
120 (37)
250 (76)
465 (142)
950 (290)
1460 (445)
GAS
SUPPLY
MANUAL
SHUTOFF
VALVE
(REQUIRED)
SEDIMENT
TRAP
Fig. 18 − Typical Gas Pipe Arrangement
1740
1670
1600
1530
1490
1420
1350
1275
1415
1345
1275
1200
1260
1195
1130
1065
955
885
805
30
40
97 (30)
82 (25)
200 (61)
170 (52)
375 (114)
320 (98)
770 (235)
660 (201)
1180 (360)
990 (301)
UNION
441 01 1422 00
1470
1205
1130
995
735
670
50
73 (22)
151 (46)
285 (87)
580 (177)
900 (274)
A02035
A02075

Advertisement

Table of Contents
loading

Table of Contents