Pentair Pool Products IntelliChlor SCG Installation Manual

Pentair Pool Products IntelliChlor SCG Installation Manual

Replacement parts for easytouch, intellitouch pool & spa control system

Advertisement

Quick Links

IntelliChlor Salt Chlorine Generator
(SCG) Replacement Parts
®
®
(For EasyTouch
, IntelliTouch
Pool & Spa Control System
®
with IntelliChlor
SCG)
Installation Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
EasyTouch
/IntelliTouch
SCG Power Supply Replacement Parts Installation Guide
®
®

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Pool Products IntelliChlor SCG

  • Page 1 IntelliChlor Salt Chlorine Generator (SCG) Replacement Parts ® ® (For EasyTouch , IntelliTouch Pool & Spa Control System ® with IntelliChlor SCG) Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS EasyTouch /IntelliTouch SCG Power Supply Replacement Parts Installation Guide ®...
  • Page 2: Table Of Contents

    SCG Transformer Assembly Removal and Installation ......5 SCG Transformer High Voltage Wiring ............ 8 IntelliChlor SCG Power Supply Replacement kit Contents ..... 8 © 2011 Pentair Water Pool and Spa, Inc. All rights reserved. 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 •...
  • Page 3: Warning And Safety Instructions

    IMPORTANT WARNING AND SAFETY INSTRUCTIONS SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT (UNIT) IS NOT INSTALLED AND USED CORRECTLY. INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. This Guide provides installa- tion and operation instructions for the product.
  • Page 4: Introduction

    Introduction This manual describes how to remove and install the EasyTouch and IntelliTouch IntelliChlor Salt Chlorine Generator (SCG) replacement parts. Summary Installation Steps • Before removing and replacing part first switch OFF the main power to the EasyTouch/IntelliTouch load center. •...
  • Page 5: Removal And Installation

    Retaining Screws (2x) High voltage Load center cover panel front door Power Center (front view) (front door and high voltage panel removed) Load Center (front view) (front door and high voltage panel removed) Loosen the two retaining screws securing the automation control panel. Lower the control to allow access the low voltage compartment behind the control panel.
  • Page 6: Scg Power Cable Removal And Installation

    SCG Power Cable Removal and Installation Before removing and installing the SCG circuit board, first be sure to switch OFF the main AC power to the load/power center. Note: Before removing the SCG connection cable, remove the high voltage panel and fold down the control panel (see page 1). To remove and replace the SCG connection cable: Removal: Carefully disconnect the cable from the SCG circuit board.
  • Page 7: Scg Circuit Breaker Assembly Removal And Installation

    To remove and install the SCG circuit board - see Figure 1 and 2 on page 7 & 8: Carefully disconnect the RED lead from the SCG breaker. Disconnect the COM port plug, power connector, RED transformer lead, and the GREEN ground lead from the enclosure base. Remove the three (3) screws securing the SCG circuit board.
  • Page 8: Scg Transformer Assembly Removal And Installation

    SCG Transformer Removal and Installation Before removing and installing the SCG transformer, first be sure to switch OFF the main AC power to the load/power center. To remove the SCG transformer assembly (see Figure 1 & 2, page 7 & 8): Remove the screw securing the green ground wire and the circuit breaker bracket to the enclosure.
  • Page 9 CAUTION: Do not overtighten rectifier mounting screw Ground Wire/Screw (Tighten 10 lb-in max.) (Circuit Breaker Bracket) Circuit Breaker Bracket Screw (8-32 x 3/8”) Circuit Breaker Circuit Board Screw (8-32 x 7/8”) (Tighten 10 lb-in max.) Transformer green/yellow GRN wire (screw, 8-32 x 3/8”) Transformer screw (4x) (8-32 x 3/8”) SCG Transformer primary...
  • Page 10 Ground Wire/ CAUTION: Do not overtighten Screw (Circuit rectifier mounting #10-32x3/4 Breaker Bracket) screw (Tighten 10 lb-in max.) Power Cable COM Port connector (To EasyTouch/ IntelliTouch Circuit Board Circuit Board #8-32x7/ SCG Circuit 8”Screw Breaker (12A) (Tighten 10 lb-in max.) RED transformer wire (3/16”...
  • Page 11: Scg Transformer High Voltage Wiring

    (GFCI) to protect the circuit. INPUT: 120 VAC AT 2.5 A, 50/60 Hz 240 VAC AT 1.3 A, 50/60 Hz Figure 3: SCG Transformer AC Wiring Diagram IntelliChlor SCG Power Supply Replacement kit Contents Description Part Number SCG Transformer P/N 521299...
  • Page 12 *521093* P/N 521093 Rev A EasyTouch /IntelliTouch SCG Power Supply Replacement Parts Installation Guide ® ®...