C Inspection And Maintenance Work - Overview - Vaillant auroCOMPACT VSC S/4 Series Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Appendix
Code Parameter
D.200 Solar function
D.201 Temperature sensor on the lower
part of the cylinder
D.202 Collector temperature sensor
D.203 Solar pump speed
D.205 Solar yield
D.206 Maximum cylinder temperature with
solar energy
D.207 Solar flow rate
D.209 Operating hours of the solar pump
D.210 Brine concentration
D.211 Reset the solar yield
D.212 Delta T between the cylinder temper-
ature and solar panel in operation
D.213 Delta T between the cylinder tem-
perature and solar panel when the
system is idle
D.217 Collector surface area
Inspection and maintenance work – Overview
C
No.
Work
Check the air/flue pipe for leak-tightness and to ensure that it is fastened correctly. Make sure
1
that it is not blocked or damaged and has been installed in accordance with the relevant Installa-
tion Manual.
Check the general condition of the unit. Remove dirt from the product and from the combustion
2
chamber.
Visually inspect the general condition of the heating block. In doing so, pay particular attention
3
to signs of corrosion, rust and other defects. If you notice any damage, carry out maintenance
work.
Check the gas connection pressure at maximum heat input. If the gas connection pressure is not
4
within the specified range, carry out maintenance work.
Check the CO₂ content (the air ratio) of the product and, if necessary, adjust it. Keep a record of
5
this procedure.
Disconnect the product from the power mains. Check that the electrical plug connections and
6
other connections are seated correctly and correct these if necessary.
7
Close the gas isolator cock and the service valves.
Drain the product's heating circuit. Check the pre-charge pressure of the expansion vessel and
8
top up the vessel, if necessary (approx. 0.3 bar below the system filling pressure).
Allow the pressure in the hot water circuit to fall. Check the pre-charge pressure of the expan-
9
sion vessel in the shift-load cylinder (if installed). Correct the pressure, if necessary.
10
Check the extent to which the anode is corroded and replace it if necessary.
Remove the compact thermal module.
11
Check all seals in the combustion area, in particular the seal on the burner door. If you see any
12
damage, replace the seals.
Clean the heat exchanger.
13
Check that the burner is not damaged and, if required, replace it.
14
Check the condensate siphon in the product, clean and fill if necessary.
15
50
Values or explanations
0 = Function activated
1 = Function deactivated
−99 ... 120 ℃
−99 ... 155 ℃
In %, adjustment range: 0 to 100
In kWh
20 ... 80 ℃
0 ... 15.15 l/min
h
0 ... 100 %
0 = Solar yield not initialised
1 = Solar yield initialised
7 ... 20 ℃
2 ... 5 ℃
2
In m
, between 1 and 10
Installation and maintenance instructions auroCOMPACT 0020181589_04
Default
User-spe-
setting
cific setting
0 = Function
activated
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
80 °C
Not ad-
justable
Not ad-
justable
42
7
3
2
Mainten-
ance
Inspection
(at least
(annual)
every
2 years)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X