Depending on how you connect
5.
the hose (A, B or C), secure the
drain hose with the remaining
accessories on the other side.
Caution!
Blocked water can be drawn back
into the dryer and may cause
material damage.
Check that the water drains away
from the wash basin quickly.
The drain must not be sealed or
blocked.
Caution!
Material damage due to leaks or
draining water.
Secure the drain hose so that it
cannot slip out. Do not kink the drain
hose. Observe the height difference
between the installation surface and
the drain of max. 100 cm, and 80
cm for a drain in a siphon.
Pull out the condensate container
6.
fully.
Installation and connection
Turn the condensate container 180°
7.
onto its underside and remove
the stopper that is fitted. Turn
the condensate container back and
insert the stopper into the recess on
the top side of the condensate
container.
Pull the filter out of the notch and
8.
place it into the recess on
the condensate container.
Slide in the condensate container
9.
until it clicks into place.
The condensation is now discharged via
the drain hose into the waste-water
system or into a wash basin.
If you want to change the
Note:
condensation drain back to
the condensate container, carry out
these steps in reverse order.