System Requirements; Driver Support; Rebuild The M.2 Cards As A Raid Device - Dell EMC ScaleIO Ready Node 14G Manual

Hide thumbs Also See for EMC ScaleIO Ready Node 14G:
Table of Contents

Advertisement

Installing the Operating System

System requirements

Driver support

Rebuild the M.2 cards as a RAID device

Hardware Configuration and Operating System Installation Guide - ESXi Servers
26
To deploy on a server in the ScaleIO Ready Node environment, the following
prerequisites must be met:
Note
For OS installation guidelines, refer to the operating system vendor's documentation,
taking into account the ScaleIO Ready Node prerequisites listed in this section.
Configure the M.2 device on the BOSS as a RAID 1 device.
l
During OS installation, use Scaleio123 as the password for the user name root or
l
administrator. (Alternately, provide a password that meets the local security
criteria.)
In a 2-Layer installation, EMC supplies a ScaleIO Ready Node image ISO.
l
Follow the wizard installation steps. The default password is Scaleio123. If
required, you can change the password by using the passwd command.
Install the OS on the BOSS device.
l
The ScaleIO Ready Node server may ship with a factory-installed, customized
l
ESXi image for use with the ScaleIO AMS solution. Before installing the OS on
systems that use the ScaleIO plug-in, you must revert the ISO to a VMware-based
image that is compatible with the plug-in. For information, see
ESXi ISO Image to a native ESXi Image
be installed from scratch, continue to
server
on page 30.
Ensure that correct drivers are installed in your system.
The best source for supported storage drivers is the Dell customized ISO for ESXi 6.5
U1. If this cannot be used, consult the VMware support matrix for Dell products on the
VMware website.
For the Dell HBA 330 Mini controller, both the customized and the release versions of
ESXi 6.5 U1 have the minimum supported driver version. However for the H740P
controller, only the customized ISO has the correct driver for lsi-mr3,
7.700.50.00-1OEM.650.0.0.4598673.
Note
Before enabling DirectPath, ensure that the correct driver is installed.
The BOSS device consists of two 120 GB M.2 expansion cards. Rebuild the M.2 cards
as a RAID 1 device.
Procedure
1. Power on the node.
2. In the iDRAC Virtual KVM console, press F2 immediately after you see the
message F2 = System Setup during system start up.
on page 27. In cases where the image will
Map the ISO file on a ScaleIO Ready Node
Revert the AMS