9.6.

Operation Control

9.6.1.
Odour Cut Control
• Odour cut operation removes the odour generated at indoor heat exchanger by using drain water come out from indoor heat
exchanger.
• Press "Odour" button at remote control to enable odour cut operation.
• Odour cut operation starts when compressor or thermostat is on.
Thermostat & Compres-
sor ON/OFF
Time
Cooling
Soft Dry
9.6.2.
Drain pump Control
• During Cooling or Soft Dry operation, drain pump operates by following the table below.
• When compressor start, drain pump operating starts after 10 seconds of indoor fan starts.
• When operation stop or thermostat is off, drain pump continue operates for 6 minutes to prevent the drain water from coming
back.
Thermostat &
Compressor ON
40 sec.
50 sec.
Off
Lo
Normal
Operation
Off
Lo
Lo
Thermostat &
Compressor OFF
-
20 sec.
120 sec.
Lo
Off
Lo
Off
41
Thermostat &
Compressor ON
20 sec.
40 sec.
50 sec.
Lo
Off
Lo
Lo
Off
Lo
-
Normal
Operation
Lo