Operating Instructions; Charging The Battery; Attaching & Detaching The Battery Pack; Switch Operations - ABB B-CK 240 Operating Instructions Manual

Hydraulic compression tool set
Table of Contents

Advertisement

3.0
3.1
1. Connect the power cord of Charger BATC-230 to a 230V 50Hz outlet. The Left LED Lamp Illuminates Red [STAND BY].
2. Insert the Battery rmly into the charger.
The Right LED Lamp Illuminates Green [CHARGING].
NOTE: Do not short-circuit the Charger by placing foreign materials in the contacts on Charger, as this will damage the Charger
and expose the user to potential safety hazards.
3. Charging takes approximately 60 minutes (100% capacity).
When charging is complete, the Right LED Lamp Blinks GREEN [COMPLETION].
NOTE: Alternate LED Lamp displays as shown:
Left LED:
Indicates Operating Mode
RED shines:
Charger in operation
RED blinks:
Charging error
(Malfunction)
Right LED:
Indicates Operating Mode:
GREEN shines:
Battery is recharging
GREEN blinks:
Battery is fully charged
RED shines:
Battery is fully defective
RED blinks:
Charging error
(battery is overheated / cold)
Leave the battery in the charging slot until the correct
temperature has been reached and charging is possible.
RED
Stop
3.2
ATTACHING & DETACHING THE BATTERY PACK
1. To attach the Battery, slide
it into the base of the Tool
until it stops and the Latch
engages.
2. After inserting the Battery,
check that it is securely in
place by pulling it gently
without pressing the Latch.
3. To detach the Battery, pull
out the Battery while
pressing the Latch.
Press Latch
for Detaching
Battery

OPERATING INSTRUCTIONS

CHARGING THE BATTERY

GREEN
100%
LED Lamp
RED
Bottom
of Tool
Detach
Insert
IMPORTANT INFORMATION! (see Step 4.3)
The lithium ion battery pack LiA-34 will be
automatically calibrated for optimized charging
operation:
Left LED:
Indicates Operating Mode:
RED shines:
Charger in operation
Right LED:
Indicates Operating Mode:
GREEN shines, RED blinks four times additionally.
Charging starts after calibration as described above.
Battery
S to p
1 0 0
%
Left
Right
LED Lamp
3.3

SWITCH OPERATIONS

1. The ram advances when the Trigger is depressed and
stops when the Trigger is released.
2. To retract the ram, depress the Release Button. The ram
continues to retract while the Release Button is depressed.
Work Light
Button
Release
Button
Trigger
TA04902 C Page 4 of 8

Advertisement

Table of Contents
loading

Table of Contents