Download Print this page
Dimplex PLX Series Installation And Operating Instructions

Dimplex PLX Series Installation And Operating Instructions

Panel convector heaters

Advertisement

Quick Links

PLX Panel Convector Heaters
Dimensions
(millimetres)
Model(s)
PLX 500/NC/TI/WTI
PLX 625/NC
PLX 750/NC/TI
PLX 1000/NC/TI/WTI
PLX 1250/NC/TI
PLX 1500/NC/TI/WTI
PLX 2000/NC/TI/WTI/TX
PLX 3000/TI/TX
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electrical shock, and injury to persons, including the
following:
IMPORTANT – If the heater is installed in a room
containing a bath or shower, it must be so installed that
switches and other controls cannot be touched by a
person using a bath or shower.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING
POOL.
Do not use outdoors.
Do not locate the heater immediately below a fixed socket
outlet or connection box.
Do not cover the heater. NEVER cover or obstruct in any
way the heat outlet slots at the top of the heater or the
air inlet slots in the base of the heater. Do not place
material or garments on the heater, or obstruct the air
circulation around the heater, for instance by curtains
or pushing furniture up against the heater, as this could
cause overheating and a fire risk.
The heater carries the Warning symbol indicating
that it must not be covered.
WARNING – THE SURFACES OF THIS HEATER CAN BE HOT.
Momentary contact with any part of the heater should
not cause injury. However, aged or infirm persons or
young children should not be left unsupervised in the
vicinity of the heater unless a suitable guard is fitted.
This appliance is not intended for use by children or
other persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.
Note that due care and consideration must be taken
when using this heater in series with a thermal control,
a program controller, a timer or any other device that
switches on the heat automatically, since a fire risk
exists when the heater is accidentally covered or
displaced.
If the supply cord is damaged it must be replaced by the
manufacturer or service agent or a similarly qualified
person in order to avoid a hazard.
WARNING: Servicing & product repairs should only be
undertaken by the manufacturers approved service
agent or a similarly qualified person, using only exact
manufacturer approved spare parts.
Watt
A
500
450
625
688
750
620
1000
620
1250
688
1500
688
2000
860
3000
860
Installation and Operating Instructions
150
MIN
B
108
108
108
108
108
108
108
143
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
The electrical installation must be carried out by a competent
electrician, and be in strict accordance with the current I.E.E.
regulations for Electrical Equipment in Buildings.
The heater is fitted with a length of flexible cable type H05VV-
F size 3 x 1.0mm
1.5mm
2
on PLX 3000 models, for connection to the fixed
wiring of the premises through a suitable connection box
positioned adjacent to the heater.
The supply circuit to the heater must incorporate a double
pole isolating switch having a contact separation of at least
3mm.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing
conductor in the supply cord is deemed to provide the
supplementary bonding connection (see Regulation 544.2.5,
th
17
Edition I.E.E. Wiring Regulations).
General
NOTE: The PLX Convector is designed for wall mounting on
the wall brackets supplied. The wall brackets supplied with
the appliance must be used. It should only be operated when
in the upright position as shown.
All models are splashproof to IP24 standard.
Models PLX...TI are fitted with a 24 hour programmable
timer.
Models PLX...TX are fitted with a 7 Day programmable timer.
Models PLX...NC are fitted with no controls, for use with
external thermostatic or programming controllers.
Before connecting the heater check that the supply voltage is
the same as that stated on the heater.
Please note that lit cigarettes, candles and oil burners,
combined with the convection effect of electric heaters
can cause soot deposits to build up on the surface directly
above and to the sides of the heater. This is not the fault of
the heater. Extensive burning of candles or smoking in the
operating environment of this product can produce heavy
discoloration within a few months of use.
INDPUKP5RG Issue 3
A
'x'
2
on models PLX 500 - 2000 and size 3 x
B
150
MIN
430
150
MIN
Fig. 1

Advertisement

loading

Summary of Contents for Dimplex PLX Series

  • Page 1 Installation and Operating Instructions PLX Panel Convector Heaters INDPUKP5RG Issue 3 Dimensions (millimetres) ‘x’ Model(s) Watt PLX 500/NC/TI/WTI PLX 625/NC PLX 750/NC/TI PLX 1000/NC/TI/WTI 1000 PLX 1250/NC/TI 1250 PLX 1500/NC/TI/WTI 1500 PLX 2000/NC/TI/WTI/TX 2000 PLX 3000/TI/TX 3000 Fig. 1 IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Important Safety Advice Electrical When using electrical appliances, basic precautions...
  • Page 2 Thermostat Operation Wall Mounting IMPORTANT – The wall brackets supplied with the appliance The heater is fitted with an adjustable thermostat enabling must be used. The heater should be positioned observing the room temperature to be controlled by adjusting the setting the minimum clearances stated around the heater - see accordingly.
  • Page 3 The programme may be over-ridden at any time by switching Should you require after sales information or assistance with this product please go to www.dimplex.co.uk where and can be reinstated by switching back to you will find our self help guide by clicking on “After Sales”...
  • Page 4 Republic of Ireland Tel. 01 8424833 [c] GDC Group Ltd, All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex. A division of GDC Group Ltd,...

This manual is also suitable for:

Plx 625/ncPlx 1000/wtiPlx 1500/wtiPlx 2000/wti501113902223305011139022264 ... Show all