Product Specifications - Amana ACVC96 Manual

Two-stage, variable-speed ecm gas furnace up to 96% afue heating input: 40,000–120,000 btu/h
Hide thumbs Also See for ACVC96:

Advertisement

Heating Data
High Fire Input¹
High Fire Output¹
Low-Fire Steady-State Input¹
Low-Fire Steady-State Output¹
AFUE²
Temperature Rise Range (°F)
Vent Diameter³
No. of Burners
Circulator Blower
Available AC @ 0.5" ESP
Size (D x W)
Horsepower @ 1075 RPM
Speed
Electrical Data
Min. Circuit Ampacity⁴
Max. Overcurrent Device (amps)⁵
Shipping Weight (lbs)
¹
Natural Gas BTU/h
²
DOE AFUE based upon Isolated Combustion System (ICS)
³
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required).
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is
dependent on installation/code requirements and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs
will require larger wire sizes.
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connection ½" FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed
above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
SS-ACVC96
ACVC96
ACVC96
0403BNA
0603BNA
40,000
60,000
38,400
57,600
28,000
42,000
26,880
40,320
96
96
20 - 50
35 - 65
2" - 3"
2" - 3"
2
3
1.5 - 3
1.5 - 3
10" x 8"
11" x 8"
½
½
VS ECM
VS ECM
7.8
7.8
15
15
116
119
www.amana-hac.com

Product Specifications

ACVC96
ACVC96
0804CNA
1005CNA
80,000
100,000
76,800
96,000
56,000
70,000
53,760
67,200
96
96
25 - 55
45 - 75
2" - 3"
2" - 3"
4
5
1.5 - 4
2 - 5
11" x 10"
11" x 10"
¾
1
VS ECM
VS ECM
10.6
14.4
15
20
143
145
ACVC96
1205DNA
120,000
115,200
84,000
80,640
96
35 - 65
2" - 3"
6
2 - 5
11" x 11"
1
VS ECM
14.4
20
158
3