Ecm Specific Replacement Parts; Ecm Troubleshooting; Diagnostic Features - Thermo Pride OH5-85DE Operation Manual

Table of Contents

Advertisement

All installations and services must be performed by qualified service personnel.
OH5 2-STAGE
SW1
SETTING
TONS
COOL
6 OFF
5 OFF
2
4 ON
6 OFF
5 OFF
2.5
4 ON
6 OFF
5 ON
3
4 ON
6 ON
5 OFF
3.5
4 OFF
6 ON
5 OFF
4
4 ON
Factory shipped
settings
G. ECM SPECIFIC REPLACEMENT PARTS
Part Name
ECM Motor
Control Board
Motor Power Harness
Motor Control Harness
Burner Harness
Transformer
III.
ECM TROUBLE SHOOTING
A. DIAGNOSTC FEATURES
The control board is equipped with 4 green Input Status LEDs and 1 red Board Status LED. These are intended to
provide a quick view into furnace performance without requiring a voltmeter.
The green Input Status LEDs are driven by the "Y", "W", "G", and "DEHUM" inputs and are located directly
below those inputs. They will light to indicate the presence of these signals.
CFM
LOW
726
352
924
462
1276
638
1474
726
1600
814
OH5/OH2
OH11
AOPS7443/
AOPS7444
AOPS7449
350915
350915
350917
350917
350920
350920
350916
350916
350464
350464
SW1
SETTING
3 OFF
2 ON
1 OFF
3 OFF
2 ON
1 ON
3 ON
2 OFF
1 OFF
OL5/OL2
OL11
AOPS7445/
AOPS7446
AOPS7450
350915
350915
350918
350918
350921
350921
350916
350916
350464
350464
13
OH5 2-STAGE
HIGH FIRE
LOW FIRE
CFM
CFM
RISE
RISE
800
81
1008
905
72
1121
960
68
1200
OH5
OC5/OC2
2-STAGE
AOPS7448/
AOPS7454
AOPS7447
350915
350184
350917
350917
350920
350183
350928
350182
350464
350464
78
70
66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents