TdA PE200B Installation And User Manual

High speed door opener

Advertisement

Quick Links

High Speed Door Opener
Installation and Users Manual
WARNING
ONLY QUALIFIED AND EXPERIENCED
TECHNICIANS SHOULD ATTEMPT INSTALLATION
OR SERVICE TO THIS UNIT, OTHERWISE, SERIOUS
PERSONAL INJURY, DEATH, OR PROPERTY DAMAGE
MAY OCCUR.
SAVE THESE INSTRUCTIONS.
Total Door Automation (Australia) Pty Ltd
www.totaldoorautomation.com.au
sales@totaldoorautomation.com.au
Technical Support 1800 AUSTDA (1800 287 832)

Advertisement

Table of Contents
loading

Summary of Contents for TdA PE200B

  • Page 1 High Speed Door Opener Installation and Users Manual WARNING ONLY QUALIFIED AND EXPERIENCED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT, OTHERWISE, SERIOUS PERSONAL INJURY, DEATH, OR PROPERTY DAMAGE MAY OCCUR. SAVE THESE INSTRUCTIONS. Total Door Automation (Australia) Pty Ltd www.totaldoorautomation.com.au sales@totaldoorautomation.com.au Technical Support 1800 AUSTDA (1800 287 832)
  • Page 2: Table Of Contents

    Contents 1. Introduction 2. Inspection 3. General Characteristic 4. Specifications • Specifications for Electronic Control System • Specifications for Motor 5. Operating Instructions • Basic Function • Control Key/Button • Install the stroke Controller 6. Safety Instruction 7. Maintenance 8. System Operation 9.
  • Page 3: Introduction

    High Speed Door Servo Control System Introduction Thank you for choosing High Speed Door Servo Control System. Please read this manual carefully before you start to use the system. In this manual you will find instructions for how to set the operating code the control unit, malfunction diagnostics and debugging, and routine maintenance.
  • Page 4: Inspection

    High Speed Door Servo Control System Inspection All product has passed inspection and testing before is leaving the factory. When you open the unit place make sure there is no damager during shipping. Also to confirm the equipment ratings are matching your requirement. General Characteristic Our servo control system is suitable for high speed PVC and aluminum doors.
  • Page 5: Specifications

    High Speed Door Servo Control System Specification Specification for Electronic Control System Model PE200B PE500B PE700B Rated Output Power 0.75KW 1.5KW 2.2KW Supply Voltage AC 220 V±10% Speed Control Closed Loop Speed Contrlol Position Control Closed Loop Position Control Protective Function...
  • Page 6: Specifications For Motor

    High Speed Door Servo Control System Specification for Motor Rated Output Power 0.75KW 1.5KW 2.2KW Rated Speed 2,000 rpm 2,000 rpm 1,500 rpm Rated Torque 3.6Nm 7.2Nm 15Nm Heating <30℃ <30℃ <30℃ Working Temperature -35℃-50℃ -35℃-50℃ -35℃-50℃ Torque Management Automatic Torque Automatic Torque Automatic Torque System...
  • Page 7: Control Key/Button

    High Speed Door Servo Control System The system can operated via: 1) control box; 2) inching electronic control; 3) continuous automatic operation; 4) emergency stop; 5) single side operation box; 6) time delay; 7) radar and/or induction loops. Please refer to wiring terminal for eternal connections.
  • Page 8: Install The Stroke Controller

    High Speed Door Servo Control System Stroke Controller utilizes absolute encoder. Connect the absolute encoder and reducer via encoder’s axle, and fix the wings on to the reducer, than insert the aviation plug into plug receptacle. 4. Safety 1) The motor and control unit MUST ground properly; 2) During the installation, commission and operation NO ONE is permit to stand under the door and stand in the operating path;...
  • Page 9 High Speed Door Servo Control System The mounting screw for the control unit must inspect regularly to prevent screw been getting loose and falling off. Check the internal and external wirings. Check and change the oil for the redactor on regular basis. Size 0.75KW Control Uint...
  • Page 10 High Speed Door Servo Control System 1.5KW Control Unit 2.2KW Control Unit...
  • Page 11 High Speed Door Servo Control System 0.75KW Motor 1.5KW Motor...
  • Page 12 High Speed Door Servo Control System 2.2KW Motor Absolute Encoder...
  • Page 13: System Operation

    High Speed Door Servo Control System System Operation MAIN------ SERVO (dispaly) ┆ MODE: (mode) ┆ ┆ STATUS: (status) ┆ Info Mode ┆ (dispaly): Torque, Speed, Position. ┆ (mode): Manual, Auto, Jog. ┆ (status): OK, Opening, Closing, Falut, Stop, E-stop, Safty1, Safty2, Lock, Maintenance. ┆...
  • Page 14 High Speed Door Servo Control System ┆ ┆------1.Parameter ┆ ┆ ┆ ┆ ┆ ┆ Index Parameter Value Default ┆ ┆ Opening Speed 10-125 ┆ ┆ Closing Speed 10-125 ┆ ┆ Open Slowdown dis. 30-70 ┆ ┆ Close Slowdown dis. 30-70 ┆...
  • Page 15 High Speed Door Servo Control System ┆ ┆ ┆------2.Limit Switch Setting ┆ Select the limit switch type: ┆ ┆ ┆ ┆ Option Remaks ┆ ┆ Mechanical Limit Switch ┆ ┆ Absolute Encoder ┆ ┆ Proximity Switch ┆ ┆ ┆ ┆ Incremental Encoder Optional in debug mode ┆...
  • Page 16 High Speed Door Servo Control System ┆ ┆ ┆ ┆ Calibrate ┆ ┆ Failure ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆------3.RTC Config ┆ Configure the date and time of the real time clock. ┆...
  • Page 17 High Speed Door Servo Control System ┆------2.Contact Type ┆ ┆ Set the contact type. ┆ ┆ ┆ ┆ ┆ ┆ Index Parameter Value Default ┆ ┆ ┆ Ext E-Stop N.O / N.C ┆ ┆ ┆ Safety1 N.O / N.C ┆ ┆...
  • Page 18 High Speed Door Servo Control System ┆------4. Maintenance ┆ ┆ Set the work cycles before the next maintenance. ┆ ┆ ┆ ┆ ┆ ┆ Maintenance ┆ ┆ ┆ 0 Thousand ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ Save +...
  • Page 19 High Speed Door Servo Control System ┆ ┆------5.Language Set the system language. ┆ ┆ ┆ ┆ Language ┆ ┆ English ┆ ┆ ┆ ┆ ┆ ┆ Save ┆ ┆ ┆ ┆ ┆ ┆------6.Default Restore factory settings. ┆ ┆ ┆ Default ? ┆...
  • Page 20 High Speed Door Servo Control System ┆------2.Sum Counter ┆ Displays the work cycles. ┆ ┆ ┆ ┆ Sum Counter ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆------3.Maint Counter ┆ Displays the work cycles after maintenance. ┆ ┆ ┆...
  • Page 21 High Speed Door Servo Control System ┆------Err Shows the current error message. ERR 19 Absolute Encoder Failure...
  • Page 22: Error Table

    High Speed Door Servo Control System Error Table: Error Code Content ERR01 Overcurrent ERR03 Under Voltage ERR04 Over Voltage ERR05 Over Voltage ERR06 Locked Rotor ERR07 Out Of Limit Position ERR08 EEPROM Failure ERR09 Over Speed ERR10 Motor Reversion ERR11 Overload ERR12 Sample Current Failure...
  • Page 23: Port Table

    High Speed Door Servo Control System 0.75KW Port Table Port Function Remark AC220V input Braking resistor output + Braking resistor output - Motor brake + DC 96V Motor brake - Com/Gnd Manual open input Manual close input Manual stop input Emergency stop input DC24V+ Com/Gnd...
  • Page 24 High Speed Door Servo Control System 1.5KW&2.2KW Port Table Port Function Remark AC220V input Braking resistor output - Braking resistor output + Motor brake - DC 24V Motor brake + Reserved Safety input 1 NO (Safety edge, photocell, etc.), stop NO (Safety edge, photocell, etc.), reverse to open limit Safety input 2 when closing...

This manual is also suitable for:

Pe500bPe700b

Table of Contents