Clearances - Empire Heating Systems SR-6-4 Installation Instructions And Owner's Manual

Unvented room heater
Table of Contents

Advertisement

When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Left side 8 inches (203mm). Right side 8 inches (203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
Refer to Figures 9, 10, 11 and 12 for measurements in order to locate (4) mounting holes on wall. Figures 9, 10, 11 and 12 are the front
views of the heaters.
1. Remove lower louver from casing assembly (2 screws).
2. Remove reflector from casing assembly (2 screws).
3. Remove upper louver from casing assembly (2 screws).
1 3/32"
2"
(28mm)
(51mm)
18 7/8"
(479mm)
4 1/32"
(102mm)
MOUNTING HOLE LOCATIONS
VIEWED FROM FRONT OF HEATER
Figure 9 (SR-6)
Page 10
SR-30 CLeARAnCeS
WALL MOUnT InSTALLATIOn
11 13/16"
(300mm)
7 13/16"
(198mm)
2"
(51mm)
22"
(559mm)
OUTLINE OF
OUTER CASING
2" MIN (51mm)
FLOOR
CEILING
SIDE WALL
36" MIN
8" MIN.
2" MIN
FLOOR
Figure 8 (SR-30)
11 13/16"
(300mm)
7 13/16"
(198mm)
1 3/32"
2"
(28mm)
(51mm)
18 7/8"
(479mm)
OUTLINE OF
OUTER CASING
4 1/32" MIN
(102mm)
FLOOR
MOUNTING HOLE LOCATIONS
VIEWED FROM FRONT OF HEATER
Figure 10 (SR-10)
8" MIN.
2"
(51mm)
22"
(559mm)
2" MIN (51mm)
35963-0-0615