Kenwood TK-P701 Service Manual page 5

Table of Contents

Advertisement

4. Clone mode
Programming data can be transferred from one trans-
ceiver to another by connecting them via their SP/MIC con-
nectors.
Cloning can be performed as described below (the trans-
mit transceiver is the source and the receive transceiver is
the target).
The following data cannot be cloned.
• Tuning data
• Model name data
• ESN data
1. Turn the source transceiver and target transceiver power
OFF.
2. Turn the source transceiver power ON while pressing the
[PTT] and [Side] keys, to enter clone mode.
3. Connect the cloning cable (part No. E30-3410-05) to the
SP/MIC connectors on the source and target transceiv-
ers.
4. Turn the target transceiver power ON.
5. Press the [Side] key on the source transceiver. The data of
the source is sent to the target. While the source is send-
ing data, red LED will light. While the target is receiving
the data, green LED will light. When cloning of data is
completed, the source red LED turned off, and the target
automatically operates in the User mode.
6. Additional targets can be continuously cloned. When
the [Side] key on the source is pressed, the data of the
source is sent to the target again. Repeat steps 3 to 5 to
clone additional transceivers.
REALIGNMENT
Note:
The Model name and Market codes must be the same in
order to clone the transceiver.
If the transceivers clone mode is confi gured as "Disabled",
the transceiver cannot enter clone mode.
If the Read authorization password is set to the trans-
ceiver, the transceiver cannot enter to the clone mode.
Cannot be cloned if the password (overwrite password) is
programmed to the target.
TK-P701
Cloning cable
(E30-3410-05)
Fig. 2
5

Advertisement

Table of Contents
loading

Table of Contents