Advertisement

Quick Links

http://www.generac.com/service-support/product-support-lookup
Para español , visita:
Pour le français, visiter :
SAVE THIS MANUAL FOR FUTURE REFERENCE
Owner's Manual
Generac PWRcell™ Battery
Loss of life. This product is not intended to
be used in a critical life support application.
Failure to adhere to this warning could result
in death or serious injury.
Register your Generac product at:
WWW.GENERAC.COM
Register your Generac product at:
WWW.GENERAC.COM
http://www.generac.com/service-support/product-support-lookup
For
OFF
ON
WARNING
1-888-GENERAC
(888-436-3722)
1-888-GENERAC
(1-888-436-3722)
0009890
(000209b)

Advertisement

Table of Contents
loading

Summary of Contents for Generac Power Systems PWRell 0009890

  • Page 1 Owner’s Manual Generac PWRcell™ Battery 0009890 WARNING Loss of life. This product is not intended to be used in a critical life support application. Failure to adhere to this warning could result in death or serious injury. (000209b) Register your Generac product at: WWW.GENERAC.COM 1-888-GENERAC (888-436-3722)
  • Page 2 Use this page to record important information about your Generac Product Record the information found on your unit data label on this that all maintenance for safe operation is performed promptly, Serial Number Locations and to have the equipment checked periodically by an ASD. page.
  • Page 3: Table Of Contents

    Table of Contents Section 1:Safety Rules & General About Generac PWRcell Battery ......8 Information Communication ........... 8 Introduction ............1 System Operational Modes ........ 8 Read This Manual Thoroughly ........1 Inverter Control Panel ......... 8 Safety Rules ............1 Battery State of Charge (SoC) Setpoints ... 9 How to Obtain Service ..........1 Islanding Mode ..........
  • Page 4 This page intentionally left blank. Owner’s Manual for Generac PWRcell Battery...
  • Page 5: Section 1:Safety Rules & General Information

    Safety Rules & General Information Section 1: Safety Rules & General Information Introduction Safety Rules Thank you for purchasing a Generac PWRcell™ Battery. The manufacturer cannot anticipate every possible cir- This owner’s manual includes full details on the use, cumstance that might involve a hazard. The alerts in this operation, and maintenance of the Generac PWRcell manual, and on tags and decals affixed to the unit, are Battery.
  • Page 6: General Hazards

    Safety Rules & General Information General Hazards IMPORTANT NOTE: See individual unit specifications for required maintenance and run times pertaining to DANGER use. • Connecting Generac PWRcell to the electric utility Automatic start-up. Disconnect utility power and grid must only be done after receiving prior render unit inoperable before working on unit.
  • Page 7: Electrical Hazards

    Safety Rules & General Information Electrical Hazards Battery Hazards DANGER WARNING Electrocution. Water contact with a power Explosion. Do not dispose of batteries in a fire. Batteries are explosive. Electrolyte solution can cause source, if not avoided, will result in death burns and blindness.
  • Page 8: Safety Shutdown

    Safety Rules & General Information Safety Shutdown DANGER Electrocution. Initiate a system-wide safety shutdown and turn PWRcell Disconnect Switch OFF on all connected batteries before performing service. Failure to do so will result in death, serious injury, equipment and property damage. (000600) Figure 1-1.
  • Page 9: Section 2:General Information Specifications

    General Information Section 2: General Information Specifications Generac Generac Generac Generac Description Units PWRcell 3 PWRcell 4 PWRcell 5 PWRcell 6 Energy Total Energy 13.5 Usable Energy 11.4 14.3 17.1 Power Continuous 60 minutes 10.0 2 minutes Battery Modules Number DC Voltage (per module) 46.8 REbus...
  • Page 10: Serial Number Locations

    General Information Serial Number Locations Unit Dimensions Refer to Figure 2-1 to locate unit serial number and nameplate. Record the information from these tags so it is available if the tags are lost or damaged. When ordering parts or requesting assistance, you may be asked to provide this information.
  • Page 11: Component Locations

    General Information Battery Disconnect Switch Component Locations DANGER Electrocution. Initiate a system-wide safety shutdown and turn PWRcell Disconnect Switch OFF on all connected batteries before performing service. Failure to do so will result in death, serious injury, equipment and property damage. (000600) Figure 2-3.
  • Page 12: About Generac Pwrcell Battery

    General Information About Generac PWRcell Battery The Generac PWRcell Battery is the storage component The REbus nanogrid automates the flow of power to of the Generac PWRcell system. The Generac PWRcell enable plug-and-play setup and operation of Generac Battery used grid-connected solar PWRcell equipment.
  • Page 13: Battery State Of Charge (Soc) Setpoints

    General Information Battery State of Charge (SoC) Setpoints There are four user-adjustable setpoints related to the These setpoints are adjusted through the Generac battery state of charge (SoC): Max Absolute, Max Inverter control panel. See the Generac PWRcell Inverter Arbitrage, Min Arbitrage, and Min Absolute. Owner’s Manual for more information on using the inverter control panel.
  • Page 14: Islanding Mode

    General Information Islanding Mode Power Search In the event of a grid outage, Generac PWRcell enters DANGER Islanding Mode. During Islanding Mode, the Generac PWRcell Inverter disconnects from the utility grid and Electrocution. Turn battery disconnect OFF and de-energize REbus before touching terminals. powers the building from the REbus Nanogrid.
  • Page 15: Blackstart

    General Information Blackstart Manual Enable Figure 2-7. If LED (B) lights solid red when Battery NOTE: Blackstart voltage must be 13V or greater to Disconnect switch is turned ON, the Generac PWRcell power the system. Battery is disabled. NOTE: The Generac PWRcell Battery must be enabled Generac PWRcell can be disabled if: to blackstart.
  • Page 16 General Information This page intentionally left blank. Owner’s Manual for Genera PWRcell Battery...
  • Page 17: Section 3:Maintenance

    Maintenance Section 3: Maintenance Annual Inspection If air filter is damaged contact Generac Customer Service at 1-888-GENERAC (1-888-436-3722) or visit www.gen- DANGER erac.com for a replacement filter. Electrocution. PWRcell Battery front cover should be removed by a qualified technician only. Removing the front cover could result in death, serious injury, equipment Or property damage.
  • Page 18: Decommissioning

    Maintenance Decommissioning Decommissioning Plan. The owner of the Generac PWRCell Battery system and WARNING the qualified Generac Service Dealer shall prepare a written decommissioning plan that provides the overview Environmental Hazard. Always recycle batteries at an of the decommissioning process developed specifically official recycling center in accordance with all local for the Generac PWRCell Battery system that is to be laws and regulations.
  • Page 20 ©2019 Generac Power Systems, Inc. S45 W29290 Hwy. 59 All rights reserved. Waukesha, WI 53189 Specifications are subject to change without notice. 1-888-GENERAC (1-888-436-3722) No reproduction allowed in any form without prior written www.generac.com consent from Generac Power Systems, Inc.