* The horizontal vane angle tolerance is within +/- 5 degree.
14.4.2
Horizontal Airflow
The horizontal airflow direction louver can be adjusted manually by hand.

14.5 Timer Control

There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
14.5.1
ON Timer Control
ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than
the setting time.
This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
14.5.2
OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.
Reference point
Side View (Outer Vane)
Closed
Position
Step 1
Step 2
Step 3
Step 4
Step 5
Figure 2
72
Stopper
115º