Simon 5" TouchScreen Version 2
Installation Guide
Description
The Simon 5" TouchScreen model 60-924-RF-TS5-2 features
a color 5-inch LCD screen with a graphical user interface
designed to control basic functionality of the Simon XT (v1.3 or
later), Simon XTi, and Simon XTi-5 control panels. Up to four
touch screens can be learned (programmed) into each Simon
XT, XTi, or XTi-5 panel. Note the TouchScreen is optimized to
work with the latest features in the Simon XTi-5 Version 2.
The touch screen provides a convenient option for the
following system operations:
Arm the system (doors, windows, and motion sensors).
Disarm the system.
Activate a panic alarm to call the central monitoring station
in a nonmedical emergency.
Check system status.
Turn system controlled lights on or off (depending on your
system configuration).
Lock and unlock system-controlled door locks (depending
on your system configuration).
Open and close system-controlled garage doors
(depending on your system configuration; XTi-5 Version 2
Panel only).
Hear voice feedback of the status of the Simon XT, XTi,
XTi-5, or XTi-5 V2 control panel.
Customize color and fonts matching the interactive service
on the mobile phone (Xti-5 Panel Version 2 only).
© 2018 UTC Fire & Security Americas Corporation, Inc.
Safety Information
IMPORTANT SAFETY INFORMATION; READ ENCLOSED
WARNINGS AND SAFETY INFORMATION.
WARNING: CHOKING HAZARD.
contains items that could be choking hazards. Please
keep away from small children.
WARNING:
Disconnect panel power before servicing.
CAUTION:
Use static electricity precautions when handling
electronic components.
CAUTION:
Only the cable provided with the device can be used to
provide power.
Installation Guidelines
Use the following guidelines when adding this touch screen to
the Simon XT, XTi, XTi-5, or XTi-5 V2 system:
Power up and learn the touch screen into the panel and
verify its operation before mounting it to its permanent wall
or desktop location.
The touch screen should be the last sensor programmed
(learned) into the panel. Doing this allows the panel's
programming configuration to be properly transferred to
the touch screen.
Program (learn) the touch screen into the panel as a
sensor Using group types 00, 01, 04, 05, 06, or 07.
The touch screen will work best if mounted greater than
3 ft. (approximately 1 m) from the Simon panel.
Avoid mounting the touch screen directly behind the
Simon XT, XTi, XTi-5 or XTi-5 V2 panel on the opposite
side of the wall.
Always do a sensor test before attaching the touch screen
to the wall.
1 / 7
The product accessory bag
P/N 466-5438 • REV A • ISS 16OCT18

Advertisement

loading

Summary of Contents for Interlogix 60-924-RF-TS5-2

  • Page 1 CAUTION: Use static electricity precautions when handling Description electronic components. The Simon 5” TouchScreen model 60-924-RF-TS5-2 features a color 5-inch LCD screen with a graphical user interface CAUTION: Only the cable provided with the device can be used to provide power.
  • Page 2 Connect the wire to the power terminals as identified in Preparation Figure 4, taking particular care to ensure the marked/dashed wire attaches to the Positive lead and the To begin unmarked wire attaches to the Negative lead. Observe Separate the touch screen and the mounting base from polarity by ensuring the same wire at the touch screen the preassembled desktop stand.
  • Page 3 On the touch screen: On the panel, select a name for the touch screen by pressing EDIT next to Sensor Name. Press the Settings button (gear icon at bottom right). You can select something simple, such as “Touch Pad”, or Press the Down arrow until the Clear and Enroll use additional descriptors, such as “Bedroom Touch Pad”.
  • Page 4 To trip the touch screen, press the RF test button from the Mounting settings screen. With touch screen operation verified and tested at the You can follow the panel voice prompting to test the permanent location; mount the touchscreen either on the sensors in any order.
  • Page 5: Operation

    14. Reconnect the ends of the wire to the power terminals as Figure 6: Battery identified in Figure 4, taking particular care to ensure the marked/dashed wire attaches to the Positive lead and the unmarked wire attaches to the Negative lead. 15.
  • Page 6: Clear Operation

    Clear Operation Specifications If the Simon XT, XTi, XTi-5, or XTi-5 V2 panel is connected to Compatibility Simon XT (version 1.3 and later), an online service, some information (such as a dealer logo) Simon XTi, Simon XTi-5 can be stored in the touch screen memory. To erase touch Enhanced Compatibility XTi-5 Version 2, i.e.
  • Page 7: Contact Information

    For customer support, see www.interlogix.com/customer-support © 2018 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of United Technologies Corporation. All rights reserved. October 16, 2018 P/N 466-5438 • REV A • ISS 16OCT18...