  • Page 1 VIESMANN Installation and service instructions for contractors Wireless base station and wireless base station B For applicability, see the last page Wireless base station and wireless base station B Please keep safe. 5676 364 GB 12/2015...
  • Page 2 ■ installer or a qualified person authorised by the For replacements, use only original spare parts installer. supplied or approved by Viessmann. Regulations to be observed Safety instructions for operating the system National installation regulations If you smell gas ■...
  • Page 3 Safety instructions Safety instructions (cont.) What to do if water escapes from the appliance Danger When water escapes from the appliance there is a risk of electrocution. Switch off the heating system at the external iso- lator (e.g. fuse box, domestic power distribu- tion).
  • Page 4: Table Of Contents

    Installation sequence Overview of the installation and commissioning process ...... 11 Connecting the wireless base station to the control unit ....... 11 Logging the wireless components onto the wireless base station ..12 Logging on the wireless outside temperature sensor ......13 ■...
  • Page 5: Operational Reliability

    Safety and liability Operational reliability Danger Only operate wireless components indoors. ■ Wireless signals can interfere with electronic ■ Avoid impairment through moisture or dust. devices, particularly cardiac pacemakers, hear- ■ Ensure the wireless components do not come into ing aids and defibrillators. contact with gases, vapours or solvents and prevent If any such equipment is fitted, users should long-lasting direct insolation.
  • Page 6: Symbols

    Product information The wireless base station or wireless base station B is the interface between the Vitotronic control unit and the wireless components.
  • Page 7 Wireless remote control Vitotrol 300 RF ■ Wireless outside temperature sensor Smart Home System Vitocomfort 200 ■ Suitable wireless components for operation with the wireless base station B: ■ Wireless remote control Vitotrol 300 RF ■ Wireless outside temperature sensor ■...
  • Page 8: Observe Prior To Installation

    Thermokon (www.thermokon.de) to determine suita- ble installation locations for the wireless components. Wireless connection Fig. 1 Wireless base station Wireless repeater Wireless outside temperature sensor Heat generator Wireless remote control KM BUS...
  • Page 9: Angle Of Penetration

    Depending on the angle of penetration, the effective wall thickness changes and therefore the extent to which the electromagnetic waves are damped. Flat (unfavourable) angle of penetration (without wireless repeater) Fig. 2 Wireless base station Wireless component, e.g. Vitotrol 200 RF Cellar ceiling...
  • Page 10: Preparing The Wireless Outside Temperature Sensor

    Preparing for installation Wireless connection (cont.) Optimised angle of penetration (with wireless repeater) Fig. 3 Wireless base station Wireless repeater Wireless component, e.g. Vitotrol 200 RF Cellar ceiling Preparing the wireless outside temperature sensor After unpacking the wireless outside temperature sen- sor, leave it exposed to light for min.
  • Page 11: Overview Of The Installation And Commissioning Process

    Note down the 3-digit wireless key. This is printed on the protective foil on the front of the wireless base station. Remove the wireless module. Provisionally connect the wireless base station to the Vitotronic control unit and place it in its intended location. Place all wireless components near the wireless base station.
  • Page 12: Logging The Wireless Components Onto The Wireless Base Station

    To the Vitotronic control unit or KM BUS distributor Total length of all KM BUS cables max. 50 m Logging the wireless components onto the wireless base station 1. Note down the 3-digit wireless key. This is printed on the protective foil on the front of the wireless base station.
  • Page 13: Logging On The Wireless Outside Temperature Sensor

    Note If a wireless repeater is used, position this at least 1 m away from the wireless base station. 3. Start the Vitotronic control unit. 4. Log on the wireless components one at a time with (see the following chapter).
  • Page 14: Logging On The Vitocomfort 200

    Installation sequence Logging the wireless components onto the… (cont.) Logging on the Vitocomfort 200 Operating instructions, see chapter "Making the wireless connection to the Vitotronic control unit" Checking the reception quality of the wireless components Wireless outside temperature sensor There is no indicator for reception quality on the wire- less outside temperature sensor.
  • Page 15: Using A Wireless Repeater

    Fig. 7 Wireless repeater Wireless outside temperature sensor Wireless remote controls Wireless base station Ideally, the wireless repeater and wireless components If there are many walls and concrete ceilings, and if form a right-angled triangle, with the wireless repeater the diagonal intersection is not too pronounced, the at the apex of the right angle (see diagram).
  • Page 16: Mounting The Wireless Base Station

    Installation sequence Mounting the wireless base station Removing the wireless module Fig. 9 Fitting the wall mounting base Fig. 10 Fitting the wireless module Fig. 11...
  • Page 17: Mounting The Wireless Outside Temperature Sensor

    1. Switch the Vitotronic control unit off and then on The wireless repeater has been logged off from the again after a brief interval. wireless base station if the red LED at the front flashes (for approx. 20 s). 3. Set DIP switch 2 back to "Run".
  • Page 18 Installation sequence Logging off wireless components (cont.) Reset Power Level Wireless used Fig. 13...
  • Page 19: Diagnosis At The Wireless Base Station

    Diagnosis and service scans Diagnosis at the wireless base station The LEDs on the front of the wireless base station indi- cate different operating states. Meaning Wireless components are not operational. Green: Illuminated Wireless base station in operation ■ Flashing slowly Logging on without wireless repeater ■...
  • Page 20 Diagnosis and service scans Diagnosis at the wireless base station (cont.)
  • Page 21: Ordering Parts

    Parts lists Ordering parts The following details are required when ordering parts: ■ Serial no. (see type plate ■ Position number of the part (from this parts list)
  • Page 22: Parts List

    Parts lists Parts list 0002 0003 0001 0005 0004 0006 Fig. 14...
  • Page 23 Parts lists Parts list (cont.) Pos. Part 0001 Wall mounting base 0002 Radio module 0003 Cover, wall mounting base 0004 Plug, strain relief, fixing materials 0005 Installation and service instructions 0006 Installation instructions "Commissioning sequence"...
  • Page 24: Wireless Base Station And Wireless Base Station B

    Specification Wireless base station and wireless base station B Power supply Via KM BUS Power consumption Radio frequency 868 MHz Protection class IP rating IP 30 to EN 60529 Ensure through mounting/installation Permissible ambient temperature Operation 0 to +40 °C ■...
  • Page 25: Declaration Of Conformity

    Certificates Declaration of conformity We, Viessmann Werke GmbH & Co KG, D-35107 Allendorf, declare as sole responsible body that the listed prod- ucts comply with the provisions of the following directives: Wireless base station Wireless base station B 1999/5/EEC R&TTE Directive...
  • Page 26 Keyword index Keyword index Angle................9 Operating states............19 Angle of penetration............. 9 Parts list..............22 Connecting the wireless base station......11 Product information............6 Control unit..............11 Range................9 DIP switch..............17 Reception quality, checking........14 – Vitocomfort 200............14 – Vitotrol 200 RF and Vitotrol 300 RF......14 Fault................
  • Page 28 Applicability Serial No.: 7501917 7522984 7533853 7557080 Viessmann Werke GmbH & Co. KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com Fax: +44 1952 675040...

This manual is also suitable for:

Wireless base station b7501917752298475338537557080

Table of Contents