Operation mode
• It is possible to operate the indoor units individually or simultaneously. The priority of
operation is placed on the first unit that turned on.
• During operation, HEAT and COOL modes cannot activate at the same time for different
indoor units.
• The power indicator blinks to indicate the indoor unit is standing by for different operation
mode.
AUTO : For your convenience.
• Unit selects operation mode every 10 minutes according to the setting and room
Single
temperatures.
• Unit selects operation mode every 3 hours according to setting temperature,
Multi
outdoor temperature and room temperature.
HEAT : Unit takes a while to warm up.
COOL : Provides efficient comfort cooling to suit your needs.
DRY
: Unit operates at low fan speed to give a gentle cooling operation.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT : 20 °C ~ 24 °C / 68 °F ~ 75 °F.
COOL: 26 °C ~ 28 °C / 79 °F ~ 82 °F.
Operating conditions
Use this air conditioner under the following temperature range.
Temperature °C (°F)
COOL
HEAT
DBT: Dry bulb temperature,
18
DBT
Max.
32 (89.6)
Min.
16 (60.8)
Max.
30 (86.0)
Min.
16 (60.8)
WBT: Wet bulb temperature
Indoor unit
WBT
23 (73.4)
11 (51.8)
-
-
Single split system
Single
Multi split system
Multi
Outdoor unit
DBT
WBT
46 (114.8)
26 (78.8)
-10 (14.0)
24 (75.2)
18 (64.4)
-15 (5.0)
-16 (3.2)
-