WD12-IMPI Update SOP

Table of Contents:
WD12-IMPI Update SOP ............................................................................................................................................... 1
Start Guide .................................................................................................................................................................... 2
BMC Update Instruction ............................................................................................................................................... 3
Bios Update Instruction .............................................................................................................................................. 10

Advertisement

loading

Summary of Contents for Gigabyte WD12-IMPI

  • Page 1: Wd12-Impi Update Sop

    WD12-IMPI Update SOP Table of Contents: WD12-IMPI Update SOP ............................... 1 Start Guide ..................................2 BMC Update Instruction ............................... 3 Bios Update Instruction .............................. 10...
  • Page 2: Start Guide

    Start Guide 1. If the BMC Version is 15.01, please update BMC FW first. 2. If any other version, go to “Bios Update Instruction (Page 10)” and update directly.
  • Page 3: Bmc Update Instruction

    BMC Update Instruction 1. Dedicate / ShareNIC LAN port should be connected Network Lane. 2. Server Mgmt--> BMC network configuration 3. You can see IP address in LAN Channel 2 / LAN Channel 8 Note: If you can’t see IP address, please refer to STEP 13 (Page 9).
  • Page 4 4. Enter IP address on your browser. (Address is > https://[your IP]) 5. Click “Maintenance” and “Firmware Update”...
  • Page 5 6. If your BMC Version is 15.01, when you update you’ll need upload a key. 7. Select “Update Type” to BMC, upload BMC file(*.ima_enc), and then click “Start...
  • Page 6 firmware update” 8. Check to preserve all configuration or not 9. Click “OK” when prompted...
  • Page 7 10. Select module section “Project Name” to upgrade 11. Click “OK”...
  • Page 8 12. Click “OK” If you can’t see IP address, please follow the step below -...
  • Page 9 13. Set Configuration Address source to DynamicBmcDhcp, and reboot. 14. Or Set Configuration Address source to Static. Please noted. IP & console side should be same subnet mask.
  • Page 10: Bios Update Instruction

    Bios Update Instruction 1. If you just update BMC FW, please wait BMC to restart (Please do not power off or reboot) 2. Click “Maintenance” and “Firmware Update” 11. Chose SU8F4.bin and update 12. Click start...
  • Page 11 13. Click Flash 14. Finish, now you can reboot. Once the boot is successful, you may use shell update to F5 again.