9.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Rapid
Semi-rapid
9.6 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
Rapid
Semi-rapid
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification
Type of hob
Number of electric cooking zones
Heating technology per electric
cooking zone
Diameter of circular electric cook‐
ing zones (Ø)
Energy consumption per cooking
zone (ECelectric cooking)
Number of gas burners
Energy efficiency per gas burner
(EE gas burner)
Energy efficiency for the gas hob
(EE gas hob)
Energy consumption of the hob
(ECelectric hob)
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
EN 60350-2 - Household electric cooking appliances - Part 2: Hobs - Methods for
measuring performance
NORMAL POWER
kW
2,7
1,9
NORMAL
MINIMUM
POWER
POWER
kW
kW
2,7
0,75
1,9
0,45
MINIMUM POWER
kW
0,75
0,45
INJECTOR
NOMINAL GAS FLOW g/h
MARK 1/100
G30 28-30
mm
mbar
86
196
71
138
Left rear
Left front
Left rear
Left front
Right rear - Rapid
Right front - Semi-rapid
ENGLISH
25
INJECTOR MARK
1/100 mm
115
96
G31 37 mbar
193
136
EGD6576NOK
Built-in hob
2
Induction
14.0 cm
21.0 cm
188.6 Wh / kg
177.4 Wh / kg
2
55.0%
52.4%
53.7%
183.0 Wh / kg