Remote Panic Operation - Audiovox Prestige Platinum APS-875A Owner's Manual

4 button remote start security system with plug-in shock sensor & starter disable
Table of Contents

Advertisement

NOTE: Whenever the chirps are bypassed, the 4-chirp intrusion indicator and 3 chirp
defective zone indicator will always operate. Since these are important warnings
to you that something has happened, they cannot be eliminated.

REMOTE PANIC OPERATION

The Lock or Unlock button on your keychain transmitter also functions as a panic switch
for use in emergency situations. To use remote panic,
1. Press and hold the Lock or Unlock button on the keychain transmitter for 3 or more
seconds. The alarm will immediately sound.
2. To stop the alarm, press and hold the Lock or Unlock button on the transmitter again
for 3 seconds. If the button is not pressed, the alarm will automatically stop after 30
seconds. Also if any transmitter button other than the Lock or Unlock button is pressed
and released, the Panic mode will be turned off immediately. The normal function of
this transmitter button will be suspended during the Panic sounding period.
3. During the panic mode, the Lock and Unlock buttons can be used to lock and unlock
the doors, (if the option is installed), however once the unlock/disarm button is pressed,
the vehicle's starter inhibit device, (where installed) will be disabled allowing the
vehicle to start.
NOTE:
While in the Panic mode, pressing and releasing the Lock or Unlock buttons
will, if the option is installed, lock and unlock the doors respectively. While in the panic
mode, anytime the Unlock button is pressed, the panic feature will continue for the
allotted 30 seconds, however, the security system will be disarmed allowing the vehicle
to start.
R. F. SHOCK SENSOR MODE SELECTION
The way in which your alarm system reacts to threatening vibrations, created by attempts
to enter the vehicle by breaking a window, is adjustable by the transmitter immediately
after arming. There are 4 modes of operation that can be selected by the operator.
1. Normal Operation (default mode)
In this mode, any strong vibrations will cause the siren to sound (full
detect) for 30 seconds. Any lesser vibration will cause the siren to emit about
6 short warn away chirps, (pre-detect).
2. Stage 1 (Omit pre-detect)
In this mode, the warn away chirps created by the lesser vibration will be
deleted. If strong vibration occurs, the siren will sound.
3. Stage 2 (Omit pre & full detect)
In this mode, both the pre-detect stage, and the full trigger stage of the sensor
are defeated. The unit will not react to vibration of any magnitude.
4. Stage 3 (City Mode)
In this mode, the pre-detect chirps will change from six pre-warning tones to
a full 10 seconds of warning chirps.
The full detect trigger duration will be reduced from 30 seconds to 15 seconds.
NOTE: Setting the stage of the shock sensor will be effective for one arming cycle
only. Once the system has been disarmed, the very next arming cycle will
cause the sensor to default to the normal operation stage.
Page 10
128-6517
10 of 16

Advertisement

Table of Contents
loading

Table of Contents