The changed portions from
Ver. 1.0 are shown in blue.
6) Click the [File Update] button in the window.
7) A file selection screen opens. Select the Destination Data file to be added and click the [Open] button.
8) When the file has been successfully added, the following window opens.
9) Check the Destination Ver. window and confirm that the version has been updated.
HDR-CX190/CX190E/CX200/CX200E/CX210/CX210E/PJ200/PJ200E/PJ210_L2
Destination Ver. window
1-4. SELF-DIAGNOSIS FUNCTION
1-4-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service
mode display.Details of the self-diagnosis functions are provided in the
Instruction manual.
LCD screen
Blinks at 3.2 Hz
C
3 2
0 0
Repaired by:
Block
C : Corrected by customer
Indicates the appropriate
E : Corrected by service
step to be taken.
engineer
E.g.
13 ....
Format the "memory card".
32 ....Turn on power again.
1-4-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
C
0
4
0
0
Non-standard battery is used.
C
0
6
0
0
The battery pack temperature is high.
Memory card is unformatted.
C
1
3
0
1
Memory card is broken.
C
1
3
0
2
*
Access error
C
1
3
0
3
*
Access error (External mdedia)
C
1
3
0
4
*
Drive fault (External mdedia)
C
3
2
6
0
Difficult to adjust focus
(
E
6
1
0
0
)
(Cannot initialize focus)
E
2
0
0
0
Flash memory data are rewritten.
E
3
1
0
0
*
Drive fault
Note 1: Start the Adjust Manual in the Adjust Station and refer to the "DESTINATON DATA WRITE".
Note 2: Functions of codes with * mark are not provided in this unit.
1-3
1-4-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the "repaired
by:", "block" in which the problem occurred, and "detailed code"of the
problem.
Detailed Code
Refer to "1-4-3. Self-diagnosis Code Tabl e".
Correction
Use the InfoLITHIUM battery.
Change the battery pack or place it in a cool place.
Format the memory card.
Insert a new memory card.
Remove the power source. Reconnect it again and operate your cam-
corder again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Retry turn the power on by the power switch. If it does not recover,
check the focus drive signal of lens block (pin wa to wf of CN1005 on
the VC-651 board). If it is OK, check the focus motor drive IC (IC5306
on the VC-651 board).
Make flash memory data correct value. (Note 1)
Turn power off and turn power on again.