Page 2
Multi V 5 General Information Outdoor Units HR Unit Installation of Outdoor Units Special Guide Control System...
Page 3
General Information Multi V 5 1.Model Line-up & External Appearance 2.Combination of Outdoor Units 3.Nomenclature 4.Indoor Unit and Outdoor Unit Capacity Index...
Page 4
Multi V 5 General Information 1. Model Line-up & External Appearance CHASSIS Model Name Model ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5 ARUM260LTE5 ARUM221LTE5 ARUM241LTE5 ARUM261LTE5 ARUM280LTE5 ARUM300LTE5 ARUM320LTE5 ARUM340LTE5 ARUM360LTE5 ARUM380LTE5 ARUM400LTE5 ARUM420LTE5 ARUM440LTE5 ARUM460LTE5 ARUM480LTE5 ARUM500LTE5...
Page 5
Multi V 5 General Information 2. Combination of Outdoor Units Module(HP) Number Model Name of Units ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5 ARUM260LTE5 ARUM221LTE5 ARUM241LTE5 ARUM261LTE5 ARUM280LTE5 ARUM300LTE5 ARUM320LTE5 ARUM340LTE5 ARUM360LTE5 ARUM380LTE5 ARUM400LTE5 ARUM420LTE5 ARUM440LTE5 ARUM460LTE5 ARUM480LTE5...
Page 6
Multi V 5 General Information 3. Nomenclature Model Name Signification Multi V System with Indoor Unit using R410A ARU : Global line-up Combination of Inverter Type and Cooling Only, Heat Pump or Heat Recovery M : Inverter, Heat Pump and Heat Recovery Total Cooling capacity in Horse Power(HP) unit EX) 8HP '080' 10HP...
Page 7
1. The combination ratio is defined as the sum of indoor unit nominal capacity (kW) divided by the outdoor rated cooling capacity (kW). 2. LG guarantees the operation only within a maximum combination ratio of 130%. 3. If the client wants to go beyond 130%, please contact the local subsidiary and discuss the requirements. Please be aware that going over 130% may result in poor performance.
Page 8
Outdoor Units Multi V 5 1.Specifications 2.Dimensions 3.Piping Diagrams 4.Wiring Diagrams 5.Field Wiring 6.Electric Characteristics 7.Capacity Tables 8.Capacity Correction Factor 9.Operation Limits 10.Sound Levels 11.Accessories...
Page 9
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM080LTE5 ARUM100LTE5 ARUM080LTE5 ARUM100LTE5 Model Name Independent Unit 22.4 28.0 Cooling Btu/h 76,400 95,500 Capacity 25.2 31.5 Heating Btu/h 86,000 107,500 Cooling 4.28 5.22 Input Heating 4.78...
Page 10
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM080LTE5 ARUM100LTE5 ARUM080LTE5 ARUM100LTE5 Model Name Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch...
Page 11
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM120LTE5 ARUM140LTE5 ARUM120LTE5 ARUM140LTE5 Model Name Independent Unit 33.6 39.2 Cooling Btu/h 114,600 133,800 Capacity 37.8 44.1 Heating Btu/h 129,000 150,500 Cooling 6.84 8.39 Input Heating 8.26 9.72...
Page 12
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM120LTE5 ARUM140LTE5 ARUM120LTE5 ARUM140LTE5 Model Name Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 13
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM160LTE5 ARUM180LTE5 ARUM160LTE5 ARUM180LTE5 Model Name Independent Unit 44.8 50.4 Cooling Btu/h 152,900 172,000 Capacity 50.4 56.7 Heating Btu/h 172,000 193,500 Cooling 10.41 9.83 Input Heating 12.39 11.94...
Page 14
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM160LTE5 ARUM180LTE5 ARUM160LTE5 ARUM180LTE5 Model Name Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 15
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM200LTE5 ARUM220LTE5 ARUM200LTE5 ARUM220LTE5 Model Name Independent Unit 56.0 61.6 Cooling Btu/h 191,100 210,200 Capacity 63.0 69.3 Heating Btu/h 215,000 236,500 Cooling 11.51 14.15 Input Heating 14.69 16.76...
Page 16
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM200LTE5 ARUM220LTE5 ARUM200LTE5 ARUM220LTE5 Model Name Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 17
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM240LTE5 ARUM260LTE5 ARUM240LTE5 ARUM260LTE5 Model Name Independent Unit 67.2 72.8 Cooling Btu/h 229,300 248,400 Capacity 74.3 74.3 Heating Btu/h 253,400 253,400 Cooling 15.91 18.03 Input Heating 18.80 19.15...
Page 18
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM240LTE5 ARUM260LTE5 ARUM240LTE5 ARUM260LTE5 Model Name Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 19
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM221LTE5 ARUM241LTE5 ARUM120LTE5 ARUM120LTE5 Model Name ARUM100LTE5 ARUM120LTE5 Independent Unit 61.6 67.2 Cooling Btu/h 210,200 229,300 Capacity 69.3 75.6 Heating Btu/h 236,500 257,900 Cooling 12.06 13.68 Input Heating 14.18 16.52...
Page 20
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM221LTE5 ARUM241LTE5 ARUM120LTE5 ARUM120LTE5 Model Name ARUM100LTE5 ARUM120LTE5 Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 21
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM261LTE5 ARUM280LTE5 ARUM140LTE5 ARUM160LTE5 Model Name ARUM120LTE5 ARUM120LTE5 Independent Unit 72.8 78.4 Cooling Btu/h 248,400 267,500 Capacity 81.9 88.2 Heating Btu/h 279,400 300,900 Cooling 15.23 17.26 Input Heating 17.98 20.65...
Page 22
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM261LTE5 ARUM280LTE5 ARUM140LTE5 ARUM160LTE5 Model Name ARUM120LTE5 ARUM120LTE5 Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 23
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM300LTE5 ARUM320LTE5 ARUM180LTE5 ARUM200LTE5 Model Name ARUM120LTE5 ARUM120LTE5 Independent Unit 84.0 89.6 Cooling Btu/h 286,600 305,700 Capacity 94.5 100.8 Heating Btu/h 322,400 343,900 Cooling 16.68 18.35 Input Heating 20.20 22.95...
Page 24
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM300LTE5 ARUM320LTE5 ARUM180LTE5 ARUM200LTE5 Model Name ARUM120LTE5 ARUM120LTE5 Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 25
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM340LTE5 ARUM360LTE5 ARUM220LTE5 ARUM240LTE5 Model Name ARUM120LTE5 ARUM120LTE5 Independent Unit 95.2 100.8 Cooling Btu/h 324,800 343,900 Capacity 107.1 112.1 Heating Btu/h 365,400 382,300 Cooling 21.00 22.76 Input Heating 25.02 27.06...
Page 26
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM340LTE5 ARUM360LTE5 ARUM220LTE5 ARUM240LTE5 Model Name ARUM120LTE5 ARUM120LTE5 Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 27
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM380LTE5 ARUM400LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM140LTE5 ARUM160LTE5 Independent Unit 106.4 112.0 Cooling Btu/h 363,000 382,100 Capacity 118.4 124.7 Heating Btu/h 403,800 425,300 Cooling 24.30 26.32 Input Heating 28.52 31.19...
Page 28
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM380LTE5 ARUM400LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM140LTE5 ARUM160LTE5 Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 29
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM420LTE5 ARUM440LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM180LTE5 ARUM200LTE5 Independent Unit 117.6 123.2 Cooling Btu/h 401,300 420,400 Capacity 131.0 137.3 Heating Btu/h 446,800 468,300 Cooling 25.74 27.41 Input Heating 30.74 33.48...
Page 30
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM420LTE5 ARUM440LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM180LTE5 ARUM200LTE5 Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 31
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM460LTE5 ARUM480LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM220LTE5 ARUM240LTE5 Independent Unit 128.8 134.4 Cooling Btu/h 439,500 458,600 Capacity 143.6 148.5 Heating Btu/h 489,800 506,700 Cooling 30.06 31.82 Input Heating 35.56 37.60...
Page 32
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM460LTE5 ARUM480LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM220LTE5 ARUM240LTE5 Independent Unit High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 33
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM500LTE5 ARUM520LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM140LTE5 ARUM160LTE5 Independent Unit ARUM120LTE5 ARUM120LTE5 140.0 145.6 Cooling Btu/h 477,700 496,800 Capacity 156.2 162.5 Heating Btu/h 532,800 554,300 Cooling 31.15 33.17 Input Heating 36.78 39.45...
Page 34
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM500LTE5 ARUM520LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM140LTE5 ARUM160LTE5 Independent Unit ARUM120LTE5 ARUM120LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 35
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM540LTE5 ARUM560LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM180LTE5 ARUM200LTE5 Independent Unit ARUM120LTE5 ARUM120LTE5 151.2 156.8 Cooling Btu/h 515,900 535,000 Capacity 168.8 175.1 Heating Btu/h 575,800 597,300 Cooling 32.59 34.26 Input Heating 39.00 41.74...
Page 36
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM540LTE5 ARUM560LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM180LTE5 ARUM200LTE5 Independent Unit ARUM120LTE5 ARUM120LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 37
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM580LTE5 ARUM600LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM220LTE5 ARUM240LTE5 Independent Unit ARUM120LTE5 ARUM120LTE5 162.4 168.0 Cooling Btu/h 554,100 573,200 Capacity 181.4 186.3 Heating Btu/h 618,800 635,700 Cooling 36.91 38.67 Input Heating 43.82 45.86...
Page 38
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM580LTE5 ARUM600LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM220LTE5 ARUM240LTE5 Independent Unit ARUM120LTE5 ARUM120LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 39
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM620LTE5 ARUM640LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM140LTE5 ARUM160LTE5 173.6 179.2 Cooling Btu/h 592,300 611,400 Capacity 192.6 198.9 Heating Btu/h 657,200 678,700 Cooling 40.21 42.23 Input Heating 47.32 49.99...
Page 40
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM620LTE5 ARUM640LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM140LTE5 ARUM160LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 41
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM660LTE5 ARUM680LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM180LTE5 ARUM200LTE5 184.8 190.4 Cooling Btu/h 630,500 649,600 Capacity 205.2 211.5 Heating Btu/h 700,200 721,700 Cooling 41.65 43.32 Input Heating 49.54 52.28...
Page 42
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM660LTE5 ARUM680LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM180LTE5 ARUM200LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 43
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM700LTE5 ARUM720LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM220LTE5 ARUM240LTE5 196.0 201.6 Cooling Btu/h 668,800 687,900 Capacity 217.8 222.8 Heating Btu/h 743,200 760,100 Cooling 45.97 47.73 Input Heating 54.36 56.40...
Page 44
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM700LTE5 ARUM720LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM220LTE5 ARUM240LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 45
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM740LTE5 ARUM760LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM140LTE5 ARUM160LTE5 ARUM120LTE5 ARUM120LTE5 207.2 212.8 Cooling Btu/h 707,000 726,100 Capacity 230.4 236.7 Heating Btu/h 786,200 807,700 Cooling 47.06 49.08 Input Heating 55.58 58.25...
Page 46
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM740LTE5 ARUM760LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM140LTE5 ARUM160LTE5 ARUM120LTE5 ARUM120LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 47
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM780LTE5 ARUM800LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM180LTE5 ARUM200LTE5 ARUM120LTE5 ARUM120LTE5 218.4 224.0 Cooling Btu/h 745,200 764,300 Capacity 243.0 249.3 Heating Btu/h 829,200 850,700 Cooling 48.50 50.17 Input Heating 57.80 60.54...
Page 48
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM780LTE5 ARUM800LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM180LTE5 ARUM200LTE5 ARUM120LTE5 ARUM120LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 49
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM820LTE5 ARUM840LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM220LTE5 ARUM240LTE5 ARUM120LTE5 ARUM120LTE5 229.6 235.2 Cooling Btu/h 783,400 802,500 Capacity 255.6 260.6 Heating Btu/h 872,100 889,100 Cooling 52.82 54.58 Input Heating 62.62 64.66...
Page 50
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM820LTE5 ARUM840LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM220LTE5 ARUM240LTE5 ARUM120LTE5 ARUM120LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 51
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM860LTE5 ARUM880LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM140LTE5 ARUM160LTE5 240.8 246.4 Cooling Btu/h 821,600 840,700 Capacity 266.9 273.2 Heating Btu/h 910,600 932,000 Cooling 56.12 58.14 Input Heating 66.12 68.79...
Page 52
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM860LTE5 ARUM880LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM140LTE5 ARUM160LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 53
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM900LTE5 ARUM920LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM180LTE5 ARUM200LTE5 252.0 257.6 Cooling Btu/h 859,800 878,900 Capacity 279.5 285.8 Heating Btu/h 953,500 975,000 Cooling 57.56 59.23 Input Heating 68.34 71.08...
Page 54
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM900LTE5 ARUM920LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM180LTE5 ARUM200LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 55
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM940LTE5 ARUM960LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM220LTE5 ARUM240LTE5 263.2 268.8 Cooling Btu/h 898,000 917,100 Capacity 292.1 297.0 Heating Btu/h 996,500 1,013,400 Cooling 61.88 63.64 Input Heating 73.16 75.19...
Page 56
Multi V 5 Outdoor Units 1. Specifications Combination Unit ARUM940LTE5 ARUM960LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM220LTE5 ARUM240LTE5 High pressure sensor / High pressure sensor / High pressure protection High pressure switch High pressure switch Over-heat protection / Over-heat protection / Protection...
Page 57
Multi V 5 Outdoor Units 2. Dimensions ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5...
Page 58
Multi V 5 Outdoor Units 2. Dimensions ARUM140LTE5 / ARUM160LTE5 / ARUM180LTE5 / ARUM200LTE5 ARUM220LTE5 / ARUM240LTE5 / ARUM260LTE5...
Page 59
Multi V 5 Outdoor Units 3. Piping Diagrams 3.1 8 / 10 / 12 / 14 / 16 HP (1 Comp) 3.1.1 Heat Recovery System Cooling Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit...
Page 60
Multi V 5 Outdoor Units 3. Piping Diagrams Heating Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit Indoor HEX...
Page 61
Multi V 5 Outdoor Units 3. Piping Diagrams Oil Return/ Defrost Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 62
Multi V 5 Outdoor Units 3. Piping Diagrams Cooling-based Simultaneous Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 63
Multi V 5 Outdoor Units 3. Piping Diagrams Heating-based Simultaneous Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 64
Multi V 5 Outdoor Units 3. Piping Diagrams Balanced Simultaneous Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 65
Multi V 5 Outdoor Units 3. Piping Diagrams Upper HEX Defrost Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 66
Multi V 5 Outdoor Units 3. Piping Diagrams Low HEX Defrost Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 67
Multi V 5 Outdoor Units 3. Piping Diagrams 3.1.2 Heat Pump System Cooling Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX d n I Motor Outdoor Sub 4-Way Valve...
Page 68
Multi V 5 Outdoor Units 3. Piping Diagrams Heating Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX Indoor Unit Indoor Unit Motor Outdoor Sub 4-Way Valve Temperature...
Page 69
Multi V 5 Outdoor Units 3. Piping Diagrams Oil Return/ Defrost Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX Indoor Unit Indoor Unit Motor Outdoor Sub 4-Way Valve...
Page 70
Multi V 5 Outdoor Units 3. Piping Diagrams Upper HEX Defrost Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX d n I d n I Motor Outdoor...
Page 71
Multi V 5 Outdoor Units 3. Piping Diagrams Low HEX Defrost Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX d n I t i n d n I t i n...
Page 72
Multi V 5 Outdoor Units 3. Piping Diagrams 3.2 18 / 20 / 22 / 24 / 26HP (2 Comp) 3.2.1 Heat Recovery System Cooling Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid Indoor HEX High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit...
Page 73
Multi V 5 Outdoor Units 3. Piping Diagrams Heating Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid Indoor HEX High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit Indoor HEX...
Page 74
Multi V 5 Outdoor Units 3. Piping Diagrams Oil Return/ Defrost Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid Indoor HEX High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 75
Multi V 5 Outdoor Units 3. Piping Diagrams Cooling-based Simultaneous Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 76
Multi V 5 Outdoor Units 3. Piping Diagrams Heating-based Simultaneous Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 77
Multi V 5 Outdoor Units 3. Piping Diagrams Balanced Simultaneous Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 78
Multi V 5 Outdoor Units 3. Piping Diagrams Upper HEX Defrost Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 79
Multi V 5 Outdoor Units 3. Piping Diagrams Low HEX Defrost Operation High Temperature High Pressure Gas Indoor HEX High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor Unit HR unit Indoor HEX Indoor Unit Indoor HEX Indoor Unit...
Page 80
Multi V 5 Outdoor Units 3. Piping Diagrams 3.2.2 Heat Pump System Cooling Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX Indoor Unit Indoor Unit Motor Outdoor...
Page 81
Multi V 5 Outdoor Units 3. Piping Diagrams Heating Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX Indoor Unit Indoor Unit Motor Outdoor Sub 4-Way Valve Temperature...
Page 82
Multi V 5 Outdoor Units 3. Piping Diagrams Oil Return/ Defrost Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX Indoor Unit Indoor Unit Motor Outdoor Sub 4-Way Valve...
Page 83
Multi V 5 Outdoor Units 3. Piping Diagrams Upper HEX Defrost Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX Indoor Unit Indoor Unit Motor Outdoor Sub 4-Way Valve...
Page 84
Multi V 5 Outdoor Units 3. Piping Diagrams Low HEX Defrost Operation High Temperature High Pressure Gas High Temperature High Pressure Liquid High Temperature High Pressure Liquid (Conditional) Low Temperature Low Pressure Gas Indoor HEX Indoor HEX Indoor Unit Indoor Unit Motor Outdoor Sub 4-Way Valve...
Page 85
Multi V 5 Outdoor Units 4. Wiring Diagrams 4.1 8 / 10 / 12 HP (UXA, 1 Comp)
Page 86
Multi V 5 Outdoor Units 4. Wiring Diagrams 4.2 14 / 16 HP (UXB, 1 Comp)
Page 87
Multi V 5 Outdoor Units 4. Wiring Diagrams 4.3 18 / 20 / 22 / 24 / 26HP (UXB, 2 Comp)
Page 88
Multi V 5 Outdoor Units 5. Field Wiring 5.1 Heat Recovery System Example Connection of Communication Cable Single Outdoor Unit Outdoor Voltage range(V) Frequency Power supply Outdoor Indoor (3Ø 4wires) 60Hz [Outdoor Unit] (Main Switch) 50Hz 380-415 220-240 R S T N Switch Fuse Indoor...
Page 89
Multi V 5 Outdoor Units 5. Field Wiring Series Outdoor Unit When the power source is connected In series between the units. Outdoor ※ The below System is representative Multi V 5 System. Power supply Actual combination of outdoor unit may be different by product line-up of region. (3Ø...
Page 90
Multi V 5 Outdoor Units 5. Field Wiring WARNING • Indoor Unit ground Lines are required for preventing electrical shock accident during current leakage, Communication disorder by noise effect and motor current leakage (without connection to pipe). • Don't install an individual switch or electrical outlet to disconnect each of indoor unit separately from the power supply.
Page 91
Multi V 5 Outdoor Units 5. Field Wiring 5.2 Heat Pump System Example Connection of Communication Cable Single Outdoor Unit Outdoor Voltage range(V) Frequency Power supply Outdoor Indoor (3Ø 4wires) [Outdoor Unit] 60Hz 380V 220V (Main Switch) 50Hz 380-415V 220-240V R S T N Switch...
Page 92
Multi V 5 Outdoor Units 5. Field Wiring Series Outdoor Unit When the power source is connected In series between the units. Outdoor Power supply (3Ø 4wires) [Master] [Slave1] [Slave2] [Slave3] (Main Switch) R S T N Switch Fuse Indoor Power supply (1Ø...
Page 93
Multi V 5 Outdoor Units 5. Field Wiring WARNING • Indoor Unit ground Lines are required for preventing electrical shock accident during current leakage, Communication disorder by noise effect and motor current leakage (without connection to pipe). • Don't install an individual switch or electrical outlet to disconnect each of indoor unit separately from the power supply.
Page 94
Multi V 5 Outdoor Units 6. Electric Characteristics Wiring of Main Power Supply and Equipment Capacity 1. Use a separate power supply for the Outdoor Unit and Indoor Unit. 2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain liquid,etc.) when proceeding with the wiring and connections 3.
Page 95
Multi V 5 Outdoor Units 6. Electric Characteristics ■ 50Hz Unit Power Supply COMP Model Volts Voltage-range TOCA RLA(Cooling) RLA(Heating) 8 HP 380-415 Min.:342, Max.:456 18.2 20.0 1.20 10 HP 380-415 Min.:342, Max.:456 25.5 28.0 1.20 12 HP 380-415 Min.:342, Max.:456 25.5 28.0 11.0...
Page 96
Multi V 5 Outdoor Units 6. Electric Characteristics Unit Power Supply COMP Model Volts Voltage-range TOCA RLA(Cooling) RLA(Heating) 86 HP 380-415 Min.:342, Max.:456 172.7 190.0 41.3 81.7 98.0 7.20 10.0 88 HP 380-415 Min.:342, Max.:456 172.7 190.0 41.3 85.0 102.4 7.20 10.0 90 HP...
Page 97
Multi V 5 Outdoor Units 6. Electric Characteristics ■ 60Hz Unit Power Supply COMP Model Volts Voltage-range TOCA RLA(Cooling) RLA(Heating) 8 HP Min.:342, Max.:418 18.2 20.0 1.20 10 HP Min.:342, Max.:418 25.5 28.0 1.20 12 HP Min.:342, Max.:418 25.5 28.0 11.0 1.20 14 HP...
Page 98
Multi V 5 Outdoor Units 6. Electric Characteristics Unit Power Supply COMP Model Volts Voltage-range TOCA RLA(Cooling) RLA(Heating) 86 HP Min.:342, Max.:418 172.7 190.0 41.3 81.7 98.0 7.20 10.0 88 HP Min.:342, Max.:418 172.7 190.0 41.3 85.0 102.4 7.20 10.0 90 HP Min.:342, Max.:418 190.0...
Page 99
Multi V 5 Outdoor Units 7. Capacity Tables 7.1 Cooling Capacity 7.1.1 Standard Mode ARUM080LTE5 Cooling Capacity (8HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 22.2 1.82 26.4 2.22 28.3 2.57 29.1 2.63 29.9 2.65 31.4...
Page 100
Multi V 5 Outdoor Units 7. Capacity Tables Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 15.1 1.32 18.0 1.61 21.0 1.91 22.4 2.06 23.8 2.21 26.4 2.47 27.0 2.49 15.1 1.37 18.0 1.67 21.0 1.97 22.4 2.12 23.8 2.29...
Page 101
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (8HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 10.6 0.85 12.6 1.01 14.6 1.17 15.7 1.26 16.7 1.34 18.7 1.53 20.8 1.71 10.6 0.86 12.6 1.02 14.6 1.19 15.7...
Page 102
Multi V 5 Outdoor Units 7. Capacity Tables ARUM100LTE5 Cooling Capacity (10HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 27.7 2.21 33.0 2.71 35.4 3.14 36.4 3.20 37.4 3.23 39.2 3.25 40.2 3.27 27.7 2.27 33.0 2.80 35.4...
Page 243
Multi V 5 Outdoor Units 7. Capacity Tables 7.1.2 SLC Mode ARUM080LTE5 Cooling Capacity (8HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.24 0.31 0.37 0.45 10.7 0.57 15.4 0.76 20.4 1.00 0.25 0.31 0.38 0.46...
Page 244
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (8HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.20 0.25 0.30 0.37 0.46 11.9 0.61 15.8 0.81 0.20 0.25 0.30 0.37 0.46 11.9 0.62 15.8 0.82 0.20 0.25 0.31...
Page 245
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (8HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.12 0.15 0.19 0.23 0.28 0.38 11.4 0.49 0.12 0.15 0.19 0.24 0.29 0.38 11.4 0.50 0.13 0.16 0.20 0.24 0.29...
Page 246
Multi V 5 Outdoor Units 7. Capacity Tables ARUM100LTE5 Cooling Capacity (10HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.30 0.37 0.45 10.1 0.55 13.3 0.69 19.2 0.92 25.5 1.22 0.30 0.38 0.46 10.1 0.56 13.3 0.70 19.2...
Page 247
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (10HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.24 0.30 0.37 0.45 10.3 0.56 14.9 0.74 19.7 0.99 0.24 0.30 0.37 0.45 10.3 0.56 14.9 0.75 19.7 1.00 0.25...
Page 248
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (10HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.15 0.19 0.23 0.28 0.35 10.3 0.46 13.6 0.60 0.15 0.19 0.24 0.29 0.35 10.3 0.46 13.6 0.61 0.15 0.19 0.24...
Page 249
Multi V 5 Outdoor Units 7. Capacity Tables ARUM120LTE5 Cooling Capacity (12HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.39 0.49 0.59 12.1 0.73 16.0 0.91 23.0 1.21 30.5 1.60 0.40 0.49 0.60 12.1 0.73 16.0 0.92 23.0...
Page 250
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (12HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.32 0.39 0.48 0.58 12.4 0.73 17.9 0.97 23.7 1.29 0.32 0.40 0.48 0.59 12.4 0.74 17.9 0.99 23.7 1.30 0.32...
Page 251
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (12HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.20 0.24 0.31 0.37 0.45 12.6 0.60 16.7 0.79 0.20 0.25 0.31 0.38 0.46 12.6 0.61 16.7 0.79 0.20 0.25 0.31...
Page 252
Multi V 5 Outdoor Units 7. Capacity Tables ARUM140LTE5 Cooling Capacity (14HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.48 0.60 10.0 0.73 14.2 0.89 18.7 1.11 26.9 1.48 35.6 1.96 0.49 0.61 10.0 0.74 14.2 0.90 18.7...
Page 253
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (14HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.39 0.48 0.59 11.0 0.72 14.5 0.90 20.8 1.20 27.6 1.58 0.39 0.49 0.59 11.0 0.72 14.5 0.91 20.8 1.21 27.6...
Page 254
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (14HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.24 0.30 0.38 0.46 10.8 0.56 15.5 0.74 20.6 0.97 0.25 0.31 0.39 0.47 10.8 0.57 15.5 0.75 20.6 0.98 0.25...
Page 255
Multi V 5 Outdoor Units 7. Capacity Tables ARUM160LTE5 Cooling Capacity (16HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.60 0.74 11.5 0.90 16.2 1.10 21.3 1.38 30.7 1.84 40.7 2.44 0.60 0.75 11.5 0.91 16.2 1.12 21.3...
Page 256
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (16HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.48 0.60 0.73 12.5 0.89 16.5 1.11 23.8 1.48 31.6 1.96 0.49 0.61 0.74 12.5 0.90 16.5 1.12 23.8 1.50 31.6...
Page 257
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (16HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.30 0.37 0.47 0.57 12.2 0.69 17.6 0.91 23.3 1.20 0.30 0.38 0.47 0.57 12.2 0.70 17.6 0.92 23.3 1.21 0.30...
Page 258
Multi V 5 Outdoor Units 7. Capacity Tables ARUM180LTE5 Cooling Capacity (18HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.56 0.70 12.9 0.85 18.2 1.04 24.0 1.30 34.5 1.74 45.8 2.30 0.57 0.71 12.9 0.86 18.2 1.05 24.0...
Page 259
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (18HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.45 0.57 10.0 0.69 14.1 0.84 18.6 1.05 26.8 1.40 35.5 1.86 0.46 0.57 10.0 0.70 14.1 0.85 18.6 1.06 26.8...
Page 260
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (18HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.29 0.36 0.45 10.0 0.55 13.2 0.67 19.0 0.88 25.2 1.15 0.29 0.36 0.46 10.0 0.55 13.2 0.67 19.0 0.89 25.2...
Page 261
Multi V 5 Outdoor Units 7. Capacity Tables ARUM200LTE5 Cooling Capacity (20HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.66 10.7 0.82 14.3 1.00 20.2 1.22 26.7 1.53 38.4 2.03 50.9 2.69 0.67 10.7 0.83 14.3 1.01 20.2...
Page 262
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (20HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.53 0.66 11.1 0.81 15.7 0.98 20.7 1.23 29.8 1.64 39.5 2.17 0.54 0.67 11.1 0.82 15.7 0.99 20.7 1.24 29.8...
Page 263
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (20HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.33 0.41 0.52 11.1 0.63 14.7 0.76 21.1 1.01 28.0 1.32 0.33 0.42 0.52 11.1 0.63 14.7 0.77 21.1 1.02 28.0...
Page 264
Multi V 5 Outdoor Units 7. Capacity Tables ARUM220LTE5 Cooling Capacity (22HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.81 11.8 1.01 15.8 1.23 22.2 1.50 29.3 1.88 42.2 2.50 56.0 3.31 0.82 11.8 1.02 15.8 1.24 22.2...
Page 265
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (22HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.65 0.82 12.2 0.99 17.2 1.21 22.7 1.51 32.7 2.02 43.4 2.67 0.66 0.82 12.2 1.00 17.2 1.22 22.7 1.53 32.7...
Page 266
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (22HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.41 0.51 0.64 12.4 0.77 16.3 0.94 23.5 1.24 31.1 1.62 0.41 0.51 0.64 12.4 0.78 16.3 0.95 23.5 1.25 31.1...
Page 267
Multi V 5 Outdoor Units 7. Capacity Tables ARUM240LTE5 Cooling Capacity (24HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.91 12.9 1.14 17.2 1.38 24.3 1.69 32.0 2.11 46.1 2.81 61.1 3.72 0.92 12.9 1.15 17.2 1.40 24.3...
Page 268
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (24HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.73 10.0 0.92 13.3 1.12 18.8 1.36 24.8 1.70 35.7 2.27 47.4 3.00 0.74 10.0 0.93 13.3 1.13 18.8 1.37 24.8...
Page 269
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (24HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.46 0.57 0.72 13.5 0.87 17.8 1.06 25.6 1.39 34.0 1.83 0.46 0.58 0.72 13.5 0.88 17.8 1.07 25.6 1.41 34.0...
Page 270
Multi V 5 Outdoor Units 7. Capacity Tables ARUM260LTE5 Cooling Capacity (26HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 10.2 1.03 14.0 1.29 18.6 1.57 26.3 1.91 34.7 2.39 49.9 3.19 66.2 4.22 10.2 1.04 14.0 1.30 18.6...
Page 271
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (26HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.83 10.8 1.04 14.4 1.26 20.4 1.54 26.9 1.93 38.7 2.57 51.3 3.40 0.84 10.8 1.05 14.4 1.28 20.4 1.56 26.9...
Page 272
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (26HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.52 0.65 10.4 0.81 14.7 0.98 19.4 1.20 27.9 1.58 37.0 2.07 0.52 0.65 10.4 0.82 14.7 0.99 19.4 1.21 27.9...
Page 273
Multi V 5 Outdoor Units 7. Capacity Tables ARUM221LTE5 Cooling Capacity (22HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.69 11.8 0.86 15.8 1.04 22.2 1.28 29.3 1.60 42.2 2.13 56.0 2.82 0.70 11.8 0.87 15.8 1.06 22.2...
Page 274
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (22HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.56 0.69 12.3 0.85 17.2 1.03 22.7 1.29 32.8 1.71 43.4 2.28 0.56 0.70 12.3 0.85 17.2 1.04 22.7 1.30 32.8...
Page 275
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (22HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.35 0.43 0.54 12.0 0.65 15.8 0.80 22.9 1.06 30.3 1.39 0.35 0.44 0.55 12.0 0.67 15.8 0.81 22.9 1.07 30.3...
Page 276
Multi V 5 Outdoor Units 7. Capacity Tables ARUM241LTE5 Cooling Capacity (24HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.78 12.8 0.98 17.2 1.18 24.2 1.46 32.0 1.82 46.0 2.42 61.0 3.20 0.80 12.8 0.98 17.2 1.20 24.2...
Page 277
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (24HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.64 10.0 0.78 13.4 0.96 18.8 1.16 24.8 1.46 35.8 1.94 47.4 2.58 0.64 10.0 0.80 13.4 0.96 18.8 1.18 24.8...
Page 278
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (24HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.40 0.48 0.62 13.2 0.74 17.4 0.90 25.2 1.20 33.4 1.58 0.40 0.50 0.62 13.2 0.76 17.4 0.92 25.2 1.22 33.4...
Page 279
Multi V 5 Outdoor Units 7. Capacity Tables ARUM261LTE5 Cooling Capacity (26HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 10.2 0.87 13.9 1.09 18.6 1.32 26.3 1.62 34.7 2.02 49.9 2.69 66.1 3.56 10.2 0.89 13.9 1.10 18.6...
Page 280
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (26HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.71 10.8 0.87 14.5 1.07 20.4 1.30 26.9 1.63 38.7 2.17 51.3 2.87 0.71 10.8 0.89 14.5 1.07 20.4 1.31 26.9...
Page 281
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (26HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.44 0.54 10.5 0.69 14.8 0.83 19.5 1.01 28.1 1.34 37.3 1.76 0.45 0.56 10.5 0.70 14.8 0.85 19.5 1.03 28.1...
Page 282
Multi V 5 Outdoor Units 7. Capacity Tables ARUM280LTE5 Cooling Capacity (28HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 11.0 0.99 15.0 1.23 20.1 1.49 28.3 1.83 37.3 2.29 53.7 3.05 71.2 4.04 11.0 1.00 15.0 1.24 20.1...
Page 283
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (28HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.80 11.7 0.99 15.6 1.21 21.9 1.47 28.9 1.84 41.7 2.45 55.3 3.25 0.81 11.7 1.01 15.6 1.22 21.9 1.49 28.9...
Page 284
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (28HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.50 0.61 11.3 0.78 15.9 0.94 20.9 1.14 30.2 1.51 40.0 1.99 0.50 0.63 11.3 0.78 15.9 0.95 20.9 1.16 30.2...
Page 285
Multi V 5 Outdoor Units 7. Capacity Tables ARUM300LTE5 Cooling Capacity (30HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 11.8 0.95 16.1 1.19 21.5 1.44 30.3 1.77 40.0 2.21 57.5 2.95 76.3 3.90 11.8 0.97 16.1 1.20 21.5...
Page 286
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (30HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.77 12.5 0.96 16.7 1.17 23.5 1.42 31.0 1.78 44.7 2.37 59.2 3.15 0.78 12.5 0.97 16.7 1.18 23.5 1.44 31.0...
Page 287
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (30HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.49 0.60 11.8 0.76 16.6 0.92 21.9 1.12 31.6 1.48 41.9 1.94 0.49 0.61 11.8 0.77 16.6 0.93 21.9 1.13 31.6...
Page 288
Multi V 5 Outdoor Units 7. Capacity Tables ARUM320LTE5 Cooling Capacity (32HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 12.6 1.05 17.1 1.31 22.9 1.59 32.3 1.95 42.7 2.44 61.4 3.24 81.4 4.29 12.6 1.07 17.1 1.32 22.9...
Page 289
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (32HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.85 13.3 1.05 17.8 1.29 25.1 1.56 33.1 1.96 47.7 2.61 63.2 3.46 0.86 13.3 1.07 17.8 1.30 25.1 1.58 33.1...
Page 290
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (32HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.53 0.65 12.6 0.83 17.7 1.00 23.4 1.21 33.7 1.61 44.7 2.11 0.53 0.67 12.6 0.83 17.7 1.01 23.4 1.23 33.7...
Page 291
Multi V 5 Outdoor Units 7. Capacity Tables ARUM340LTE5 Cooling Capacity (34HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 13.4 1.20 18.2 1.50 24.4 1.82 34.3 2.23 45.3 2.79 65.2 3.71 86.5 4.91 13.4 1.22 18.2 1.51 24.4...
Page 292
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (34HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 10.4 0.97 14.2 1.21 18.9 1.47 26.6 1.79 35.1 2.24 50.6 2.99 67.1 3.96 10.4 0.98 14.2 1.22 18.9 1.48 26.6...
Page 293
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (34HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.61 10.1 0.75 13.5 0.95 19.0 1.14 25.0 1.39 36.1 1.84 47.8 2.41 0.61 10.1 0.76 13.5 0.95 19.0 1.16 25.0...
Page 294
Multi V 5 Outdoor Units 7. Capacity Tables ARUM360LTE5 Cooling Capacity (36HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 14.2 1.30 19.3 1.63 25.8 1.97 36.4 2.42 48.0 3.02 69.1 4.02 91.6 5.32 14.2 1.32 19.3 1.64 25.8...
Page 295
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (36HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 11.0 1.05 15.0 1.31 20.0 1.60 28.2 1.94 37.2 2.43 53.6 3.24 71.1 4.29 11.0 1.06 15.0 1.33 20.0 1.61 28.2...
Page 296
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (36HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.66 10.7 0.81 14.3 1.03 20.1 1.24 26.5 1.51 38.2 1.99 50.7 2.62 0.66 10.7 0.83 14.3 1.03 20.1 1.26 26.5...
Page 297
Multi V 5 Outdoor Units 7. Capacity Tables ARUM380LTE5 Cooling Capacity (38HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 15.0 1.39 20.4 1.74 27.2 2.11 38.5 2.58 50.7 3.22 73.0 4.29 96.7 5.68 15.0 1.41 20.4 1.76 27.2...
Page 298
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (38HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 11.6 1.12 15.8 1.40 21.1 1.71 29.8 2.08 39.3 2.60 56.5 3.47 75.0 4.58 11.6 1.13 15.8 1.42 21.1 1.72 29.8...
Page 299
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (38HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.70 11.5 0.87 15.4 1.10 21.7 1.33 28.6 1.62 41.1 2.13 54.6 2.80 0.71 11.5 0.89 15.4 1.11 21.7 1.35 28.6...
Page 300
Multi V 5 Outdoor Units 7. Capacity Tables ARUM400LTE5 Cooling Capacity (40HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 15.8 1.51 21.5 1.88 28.7 2.28 40.5 2.79 53.3 3.49 76.8 4.65 101.8 6.16 15.8 1.52 21.5 1.90 28.7...
Page 301
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (40HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 12.2 1.21 16.7 1.52 22.2 1.85 31.3 2.25 41.3 2.81 59.5 3.75 79.0 4.96 12.2 1.23 16.7 1.54 22.2 1.87 31.3...
Page 302
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (40HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.76 12.1 0.94 16.2 1.19 22.8 1.44 30.0 1.75 43.2 2.30 57.3 3.03 0.76 12.1 0.96 16.2 1.19 22.8 1.45 30.0...
Page 303
Multi V 5 Outdoor Units 7. Capacity Tables ARUM420LTE5 Cooling Capacity (42HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 16.6 1.47 22.6 1.84 30.1 2.23 42.5 2.73 56.0 3.41 80.6 4.55 106.9 6.02 16.6 1.49 22.6 1.86 30.1...
Page 304
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (42HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 12.8 1.18 17.5 1.49 23.3 1.81 32.9 2.20 43.4 2.75 62.5 3.67 82.9 4.86 12.8 1.20 17.5 1.50 23.3 1.83 32.9...
Page 305
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (42HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.75 12.5 0.93 16.7 1.17 23.5 1.42 31.0 1.73 44.6 2.27 59.2 2.98 0.75 12.5 0.94 16.7 1.18 23.5 1.43 31.0...
Page 306
Multi V 5 Outdoor Units 7. Capacity Tables ARUM440LTE5 Cooling Capacity (44HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 17.4 1.57 23.6 1.96 31.5 2.38 44.5 2.91 58.7 3.64 84.5 4.84 112.0 6.41 17.4 1.59 23.6 1.98 31.5...
Page 307
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (44HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 13.4 1.26 18.3 1.58 24.4 1.93 34.5 2.34 45.5 2.93 65.5 3.91 86.9 5.17 13.4 1.28 18.3 1.60 24.4 1.95 34.5...
Page 308
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (44HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 0.79 13.1 0.98 17.5 1.24 24.6 1.50 32.5 1.82 46.7 2.40 62.0 3.15 0.79 13.1 1.00 17.5 1.24 24.6 1.51 32.5...
Page 309
Multi V 5 Outdoor Units 7. Capacity Tables ARUM460LTE5 Cooling Capacity (46HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 18.2 1.72 24.7 2.15 33.0 2.61 46.5 3.19 61.3 3.99 88.3 5.31 117.1 7.03 18.2 1.74 24.7 2.17 33.0...
Page 310
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (46HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 14.0 1.38 19.2 1.74 25.5 2.11 36.0 2.57 47.5 3.21 68.4 4.29 90.8 5.67 14.0 1.40 19.2 1.75 25.5 2.13 36.0...
Page 311
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (46HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 10.1 0.87 13.8 1.08 18.4 1.36 25.9 1.64 34.1 2.00 49.1 2.63 65.1 3.45 10.1 0.87 13.8 1.09 18.4 1.36 25.9...
Page 312
Multi V 5 Outdoor Units 7. Capacity Tables ARUM480LTE5 Cooling Capacity (48HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 19.0 1.82 25.8 2.28 34.4 2.76 48.6 3.38 64.0 4.22 92.2 5.62 122.2 7.44 19.0 1.84 25.8 2.30 34.4...
Page 313
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (48HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 14.6 1.46 20.0 1.84 26.6 2.24 37.6 2.72 49.6 3.40 71.4 4.54 94.8 6.00 14.6 1.48 20.0 1.86 26.6 2.26 37.6...
Page 314
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (48HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 10.6 0.92 14.4 1.14 19.2 1.44 27.0 1.74 35.6 2.12 51.2 2.78 68.0 3.66 10.6 0.92 14.4 1.16 19.2 1.44 27.0...
Page 315
Multi V 5 Outdoor Units 7. Capacity Tables ARUM500LTE5 Cooling Capacity (50HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 19.7 1.78 26.8 2.23 35.8 2.70 50.6 3.31 66.7 4.13 96.0 5.50 127.2 7.28 19.7 1.81 26.8 2.25 35.8...
Page 316
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (50HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 15.3 1.44 20.8 1.79 27.8 2.19 39.2 2.66 51.7 3.33 74.4 4.44 98.7 5.87 15.3 1.45 20.8 1.82 27.8 2.20 39.2...
Page 317
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (50HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 11.1 0.90 15.0 1.11 20.1 1.41 28.3 1.70 37.3 2.07 53.7 2.73 71.3 3.59 11.1 0.91 15.0 1.14 20.1 1.42 28.3...
Page 318
Multi V 5 Outdoor Units 7. Capacity Tables ARUM520LTE5 Cooling Capacity (52HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 20.5 1.90 27.9 2.37 37.3 2.87 52.6 3.52 69.3 4.40 99.8 5.86 132.3 7.76 20.5 1.92 27.9 2.39 37.3...
Page 319
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (52HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 15.9 1.53 21.7 1.91 28.9 2.33 40.7 2.83 53.7 3.54 77.4 4.72 102.7 6.25 15.9 1.55 21.7 1.94 28.9 2.35 40.7...
Page 320
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (52HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 11.5 0.96 15.6 1.18 20.9 1.50 29.4 1.81 38.7 2.20 55.8 2.90 74.0 3.82 11.5 0.96 15.6 1.21 20.9 1.50 29.4...
Page 321
Multi V 5 Outdoor Units 7. Capacity Tables ARUM540LTE5 Cooling Capacity (54HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 21.3 1.86 29.0 2.33 38.7 2.82 54.6 3.46 72.0 4.32 103.6 5.76 137.4 7.62 21.3 1.89 29.0 2.35 38.7...
Page 322
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (54HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 16.5 1.50 22.5 1.88 30.0 2.29 42.3 2.78 55.8 3.48 80.4 4.64 106.6 6.15 16.5 1.52 22.5 1.90 30.0 2.31 42.3...
Page 323
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (54HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 11.8 0.95 16.0 1.17 21.4 1.48 30.1 1.79 39.7 2.18 57.2 2.87 75.9 3.77 11.8 0.95 16.0 1.19 21.4 1.49 30.1...
Page 324
Multi V 5 Outdoor Units 7. Capacity Tables ARUM560LTE5 Cooling Capacity (56HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 22.1 1.96 30.0 2.45 40.1 2.97 56.6 3.64 74.7 4.55 107.5 6.05 142.5 8.01 22.1 1.99 30.0 2.47 40.1...
Page 325
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (56HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 17.1 1.58 23.3 1.97 31.1 2.41 43.9 2.92 57.9 3.66 83.4 4.88 110.6 6.46 17.1 1.60 23.3 2.00 31.1 2.43 43.9...
Page 326
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (56HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 12.2 0.99 16.6 1.22 22.2 1.55 31.2 1.87 41.2 2.27 59.3 3.00 78.7 3.94 12.2 0.99 16.6 1.25 22.2 1.55 31.2...
Page 327
Multi V 5 Outdoor Units 7. Capacity Tables ARUM580LTE5 Cooling Capacity (58HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 22.9 2.11 31.1 2.64 41.6 3.20 58.6 3.92 77.3 4.90 111.3 6.52 147.6 8.63 22.9 2.14 31.1 2.66 41.6...
Page 328
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (58HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 17.7 1.70 24.2 2.13 32.2 2.59 45.4 3.15 59.9 3.94 86.3 5.26 114.5 6.96 17.7 1.72 24.2 2.15 32.2 2.61 45.4...
Page 329
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (58HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 12.7 1.07 17.3 1.32 23.1 1.67 32.5 2.01 42.8 2.45 61.7 3.23 81.8 4.24 12.7 1.07 17.3 1.34 23.1 1.67 32.5...
Page 330
Multi V 5 Outdoor Units 7. Capacity Tables ARUM600LTE5 Cooling Capacity (60HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 23.7 2.21 32.2 2.77 43.0 3.35 60.7 4.11 80.0 5.13 115.2 6.83 152.7 9.04 23.7 2.24 32.2 2.79 43.0...
Page 331
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (60HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 18.3 1.78 25.0 2.23 33.3 2.72 47.0 3.30 62.0 4.13 89.3 5.51 118.5 7.29 18.3 1.80 25.0 2.26 33.3 2.74 47.0...
Page 332
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (60HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 13.2 1.12 17.9 1.38 23.9 1.75 33.6 2.11 44.3 2.57 63.8 3.38 84.7 4.45 13.2 1.12 17.9 1.41 23.9 1.75 33.6...
Page 333
Multi V 5 Outdoor Units 7. Capacity Tables ARUM620LTE5 Cooling Capacity (62HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 24.5 2.30 33.3 2.88 44.4 3.49 62.8 4.27 82.7 5.33 119.1 7.10 157.8 9.40 24.5 2.33 33.3 2.91 44.4...
Page 334
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (62HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 18.9 1.85 25.8 2.32 34.4 2.83 48.6 3.44 64.1 4.30 92.2 5.74 122.4 7.58 18.9 1.87 25.8 2.35 34.4 2.85 48.6...
Page 335
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (62HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 13.8 1.16 18.7 1.44 25.0 1.82 35.2 2.20 46.4 2.68 66.7 3.52 88.6 4.63 13.8 1.17 18.7 1.47 25.0 1.83 35.2...
Page 336
Multi V 5 Outdoor Units 7. Capacity Tables ARUM640LTE5 Cooling Capacity (64HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 25.3 2.42 34.4 3.02 45.9 3.66 64.8 4.48 85.3 5.60 122.9 7.46 162.9 9.88 25.3 2.44 34.4 3.05 45.9...
Page 337
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (64HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 19.5 1.94 26.7 2.44 35.5 2.97 50.1 3.61 66.1 4.51 95.2 6.02 126.4 7.96 19.5 1.97 26.7 2.47 35.5 3.00 50.1...
Page 338
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (64HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 14.2 1.22 19.3 1.51 25.8 1.91 36.3 2.31 47.8 2.81 68.8 3.69 91.3 4.86 14.2 1.22 19.3 1.54 25.8 1.91 36.3...
Page 339
Multi V 5 Outdoor Units 7. Capacity Tables ARUM660LTE5 Cooling Capacity (66HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 26.1 2.38 35.5 2.98 47.3 3.61 66.8 4.42 88.0 5.52 126.7 7.36 168.0 9.74 26.1 2.41 35.5 3.01 47.3...
Page 340
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (66HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 20.1 1.91 27.5 2.41 36.6 2.93 51.7 3.56 68.2 4.45 98.2 5.94 130.3 7.86 20.1 1.94 27.5 2.43 36.6 2.96 51.7...
Page 341
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (66HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 14.5 1.21 19.7 1.50 26.3 1.89 37.0 2.29 48.8 2.79 70.2 3.66 93.2 4.81 14.5 1.21 19.7 1.52 26.3 1.90 37.0...
Page 342
Multi V 5 Outdoor Units 7. Capacity Tables ARUM680LTE5 Cooling Capacity (68HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 26.9 2.48 36.5 3.10 48.7 3.76 68.8 4.60 90.7 5.75 130.6 7.65 173.1 10.13 26.9 2.51 36.5 3.13 48.7...
Page 343
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (68HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 20.7 1.99 28.3 2.50 37.7 3.05 53.3 3.70 70.3 4.63 101.2 6.18 134.3 8.17 20.7 2.02 28.3 2.53 37.7 3.08 53.3...
Page 344
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (68HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 14.9 1.25 20.3 1.55 27.1 1.96 38.1 2.37 50.3 2.88 72.3 3.79 96.0 4.98 14.9 1.25 20.3 1.58 27.1 1.96 38.1...
Page 345
Multi V 5 Outdoor Units 7. Capacity Tables ARUM700LTE5 Cooling Capacity (70HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 27.7 2.63 37.6 3.29 50.2 3.99 70.8 4.88 93.3 6.10 134.4 8.12 178.2 10.75 27.7 2.66 37.6 3.32 50.2...
Page 346
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (70HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 21.3 2.11 29.2 2.66 38.8 3.23 54.8 3.93 72.3 4.91 104.1 6.56 138.2 8.67 21.3 2.14 29.2 2.68 38.8 3.26 54.8...
Page 347
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (70HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 15.4 1.33 21.0 1.65 28.0 2.08 39.4 2.51 51.9 3.06 74.7 4.02 99.1 5.28 15.4 1.33 21.0 1.67 28.0 2.08 39.4...
Page 348
Multi V 5 Outdoor Units 7. Capacity Tables ARUM720LTE5 Cooling Capacity (72HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 28.5 2.73 38.7 3.42 51.6 4.14 72.9 5.07 96.0 6.33 138.3 8.43 183.3 11.16 28.5 2.76 38.7 3.45 51.6...
Page 349
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (72HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 21.9 2.19 30.0 2.76 39.9 3.36 56.4 4.08 74.4 5.10 107.1 6.81 142.2 9.00 21.9 2.22 30.0 2.79 39.9 3.39 56.4...
Page 350
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (72HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 15.9 1.38 21.6 1.71 28.8 2.16 40.5 2.61 53.4 3.18 76.8 4.17 102.0 5.49 15.9 1.38 21.6 1.74 28.8 2.16 40.5...
Page 351
Multi V 5 Outdoor Units 7. Capacity Tables ARUM740LTE5 Cooling Capacity (74HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 29.2 2.69 39.7 3.37 53.0 4.08 74.9 5.00 98.7 6.24 142.1 8.31 188.3 11.00 29.2 2.73 39.7 3.40 53.0...
Page 352
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (74HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 22.6 2.17 30.8 2.71 41.1 3.31 58.0 4.02 76.5 5.03 110.1 6.71 146.1 8.87 22.6 2.19 30.8 2.75 41.1 3.33 58.0...
Page 353
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (74HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 16.4 1.36 22.2 1.68 29.7 2.13 41.8 2.57 55.1 3.13 79.3 4.12 105.3 5.42 16.4 1.37 22.2 1.72 29.7 2.14 41.8...
Page 354
Multi V 5 Outdoor Units 7. Capacity Tables ARUM760LTE5 Cooling Capacity (76HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 30.0 2.81 40.8 3.51 54.5 4.25 76.9 5.21 101.3 6.51 145.9 8.67 193.4 11.48 30.0 2.84 40.8 3.54 54.5...
Page 355
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (76HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 23.2 2.26 31.7 2.83 42.2 3.45 59.5 4.19 78.5 5.24 113.1 6.99 150.1 9.25 23.2 2.29 31.7 2.87 42.2 3.48 59.5...
Page 356
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (76HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 16.8 1.42 22.8 1.75 30.5 2.22 42.9 2.68 56.5 3.26 81.4 4.29 108.0 5.65 16.8 1.42 22.8 1.79 30.5 2.22 42.9...
Page 357
Multi V 5 Outdoor Units 7. Capacity Tables ARUM780LTE5 Cooling Capacity (78HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 30.8 2.77 41.9 3.47 55.9 4.20 78.9 5.15 104.0 6.43 149.7 8.57 198.5 11.34 30.8 2.81 41.9 3.50 55.9...
Page 358
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (78HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 23.8 2.23 32.5 2.80 43.3 3.41 61.1 4.14 80.6 5.18 116.1 6.91 154.0 9.15 23.8 2.26 32.5 2.83 43.3 3.44 61.1...
Page 359
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (78HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 17.1 1.41 23.2 1.74 31.0 2.20 43.6 2.66 57.5 3.24 82.8 4.26 109.9 5.60 17.1 1.41 23.2 1.77 31.0 2.21 43.6...
Page 360
Multi V 5 Outdoor Units 7. Capacity Tables ARUM800LTE5 Cooling Capacity (80HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 31.6 2.87 42.9 3.59 57.3 4.35 80.9 5.33 106.7 6.66 153.6 8.86 203.6 11.73 31.6 2.91 42.9 3.62 57.3...
Page 361
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (80HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 24.4 2.31 33.3 2.89 44.4 3.53 62.7 4.28 82.7 5.36 119.1 7.15 158.0 9.46 24.4 2.34 33.3 2.93 44.4 3.56 62.7...
Page 362
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (80HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 17.5 1.45 23.8 1.79 31.8 2.27 44.7 2.74 59.0 3.33 84.9 4.39 112.7 5.77 17.5 1.45 23.8 1.83 31.8 2.27 44.7...
Page 363
Multi V 5 Outdoor Units 7. Capacity Tables ARUM820LTE5 Cooling Capacity (82HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 32.4 3.02 44.0 3.78 58.8 4.58 82.9 5.61 109.3 7.01 157.4 9.33 208.7 12.35 32.4 3.06 44.0 3.81 58.8...
Page 364
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (82HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 25.0 2.43 34.2 3.05 45.5 3.71 64.2 4.51 84.7 5.64 122.0 7.53 161.9 9.96 25.0 2.46 34.2 3.08 45.5 3.74 64.2...
Page 365
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (82HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 18.0 1.53 24.5 1.89 32.7 2.39 46.0 2.88 60.6 3.51 87.3 4.62 115.8 6.07 18.0 1.53 24.5 1.92 32.7 2.39 46.0...
Page 366
Multi V 5 Outdoor Units 7. Capacity Tables ARUM840LTE5 Cooling Capacity (84HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 33.2 3.12 45.1 3.91 60.2 4.73 85.0 5.80 112.0 7.24 161.3 9.64 213.8 12.76 33.2 3.16 45.1 3.94 60.2...
Page 367
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (84HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 25.6 2.51 35.0 3.15 46.6 3.84 65.8 4.66 86.8 5.83 125.0 7.78 165.9 10.29 25.6 2.54 35.0 3.19 46.6 3.87 65.8...
Page 368
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (84HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 18.5 1.58 25.1 1.95 33.5 2.47 47.1 2.98 62.1 3.63 89.4 4.77 118.7 6.28 18.5 1.58 25.1 1.99 33.5 2.47 47.1...
Page 369
Multi V 5 Outdoor Units 7. Capacity Tables ARUM860LTE5 Cooling Capacity (86HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 34.0 3.21 46.2 4.02 61.6 4.87 87.1 5.96 114.7 7.44 165.2 9.91 218.9 13.12 34.0 3.25 46.2 4.06 61.6...
Page 370
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (86HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 26.2 2.58 35.8 3.24 47.7 3.95 67.4 4.80 88.9 6.00 127.9 8.01 169.8 10.58 26.2 2.61 35.8 3.28 47.7 3.98 67.4...
Page 371
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (86HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 19.1 1.62 25.9 2.01 34.6 2.54 48.7 3.07 64.2 3.74 92.3 4.91 122.6 6.46 19.1 1.63 25.9 2.05 34.6 2.55 48.7...
Page 372
Multi V 5 Outdoor Units 7. Capacity Tables ARUM880LTE5 Cooling Capacity (88HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 34.8 3.33 47.3 4.16 63.1 5.04 89.1 6.17 117.3 7.71 169.0 10.27 224.0 13.60 34.8 3.36 47.3 4.20 63.1...
Page 373
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (88HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 26.8 2.67 36.7 3.36 48.8 4.09 68.9 4.97 90.9 6.21 130.9 8.29 173.8 10.96 26.8 2.71 36.7 3.40 48.8 4.13 68.9...
Page 374
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (88HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 19.5 1.68 26.5 2.08 35.4 2.63 49.8 3.18 65.6 3.87 94.4 5.08 125.3 6.69 19.5 1.68 26.5 2.12 35.4 2.63 49.8...
Page 375
Multi V 5 Outdoor Units 7. Capacity Tables ARUM900LTE5 Cooling Capacity (90HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 35.6 3.29 48.4 4.12 64.5 4.99 91.1 6.11 120.0 7.63 172.8 10.17 229.1 13.46 35.6 3.33 48.4 4.16 64.5...
Page 376
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (90HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 27.4 2.64 37.5 3.33 49.9 4.05 70.5 4.92 93.0 6.15 133.9 8.21 177.7 10.86 27.4 2.68 37.5 3.36 49.9 4.09 70.5...
Page 377
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (90HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 19.8 1.67 26.9 2.07 35.9 2.61 50.5 3.16 66.6 3.85 95.8 5.05 127.2 6.64 19.8 1.67 26.9 2.10 35.9 2.62 50.5...
Page 378
Multi V 5 Outdoor Units 7. Capacity Tables ARUM920LTE Cooling Capacity (92HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 36.4 3.39 49.4 4.24 65.9 5.14 93.1 6.29 122.7 7.86 176.7 10.46 234.2 13.85 36.4 3.43 49.4 4.28 65.9...
Page 379
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (92HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 28.0 2.72 38.3 3.42 51.0 4.17 72.1 5.06 95.1 6.33 136.9 8.45 181.7 11.17 28.0 2.76 38.3 3.46 51.0 4.21 72.1...
Page 380
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (92HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 20.2 1.71 27.5 2.12 36.7 2.68 51.6 3.24 68.1 3.94 97.9 5.18 130.0 6.81 20.2 1.71 27.5 2.16 36.7 2.68 51.6...
Page 381
Multi V 5 Outdoor Units 7. Capacity Tables ARUM940LTE5 Cooling Capacity (94HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 37.2 3.54 50.5 4.43 67.4 5.37 95.1 6.57 125.3 8.21 180.5 10.93 239.3 14.47 37.2 3.58 50.5 4.47 67.4...
Page 382
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (94HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 28.6 2.84 39.2 3.58 52.1 4.35 73.6 5.29 97.1 6.61 139.8 8.83 185.6 11.67 28.6 2.88 39.2 3.61 52.1 4.39 73.6...
Page 383
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (94HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 20.7 1.79 28.2 2.22 37.6 2.80 52.9 3.38 69.7 4.12 100.3 5.41 133.1 7.11 20.7 1.79 28.2 2.25 37.6 2.80 52.9...
Page 384
Multi V 5 Outdoor Units 7. Capacity Tables ARUM960LTE5 Cooling Capacity (96HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 38.0 3.64 51.6 4.56 68.8 5.52 97.2 6.76 128.0 8.44 184.4 11.24 244.4 14.88 38.0 3.68 51.6 4.60 68.8...
Page 385
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (96HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 29.2 2.92 40.0 3.68 53.2 4.48 75.2 5.44 99.2 6.80 142.8 9.08 189.6 12.00 29.2 2.96 40.0 3.72 53.2 4.52 75.2...
Page 386
Multi V 5 Outdoor Units 7. Capacity Tables Cooling Capacity (96HP) Indoor air temp. (DB/WB, °C) Combination Outdoor air temp. (DB, °C) 21.2 1.84 28.8 2.28 38.4 2.88 54.0 3.48 71.2 4.24 102.4 5.56 136.0 7.32 21.2 1.84 28.8 2.32 38.4 2.88 54.0...
Page 387
Multi V 5 Outdoor Units 7. Capacity Tables 7.2 Heating Capacity 7.2.1 Standard Mode ARUM080LTE5 Heating Capacity (8HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 15.6 7.34 15.6 7.39 15.5 7.43 15.5 7.50...
Page 388
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (8HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 15.4 8.23 15.4 8.19 15.3 7.60 15.3 8.09 15.3 8.05 15.0 8.03 -21.8 18.7 8.17 18.7 8.13 18.6...
Page 389
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (8HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 15.2 6.45 15.2 6.48 15.1 6.55 15.1 6.65 15.1 6.30 14.8 5.99 -21.8 17.7 6.55 17.7 6.58 17.6...
Page 390
Multi V 5 Outdoor Units 7. Capacity Tables ARUM100LTE5 Heating Capacity (10HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 20.4 9.67 20.4 9.77 20.2 9.86 20.2 9.99 20.2 10.11 19.7 10.31 -21.8 24.7 9.87 24.7...
Page 391
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (10HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 20.0 10.27 20.0 10.34 19.9 10.06 19.9 10.53 19.9 10.61 19.4 10.65 -21.8 24.3 10.38 24.3 10.46 24.2...
Page 392
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (10HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 19.9 8.46 19.9 8.52 19.7 8.65 19.7 8.85 19.7 8.37 19.2 7.92 -21.8 22.1 8.65 22.1 8.72 21.9...
Page 393
Multi V 5 Outdoor Units 7. Capacity Tables ARUM120LTE5 Heating Capacity (12HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 23.9 11.43 23.9 11.64 23.8 11.83 23.8 12.11 23.8 12.39 23.7 12.82 -21.8 28.4 11.86 28.4...
Page 394
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (12HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 23.5 13.34 23.5 13.42 23.4 12.93 23.4 13.63 23.4 13.72 23.3 13.76 -21.8 27.9 13.47 27.9 13.55 27.8...
Page 395
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (12HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 23.3 10.53 23.3 10.67 23.2 10.96 23.2 11.39 23.2 10.81 23.0 10.26 -21.8 26.5 10.96 26.5 11.10 26.3...
Page 396
Multi V 5 Outdoor Units 7. Capacity Tables ARUM140LTE5 Heating Capacity (14HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 27.3 13.07 27.3 13.20 27.2 13.32 27.2 13.50 27.2 13.67 26.6 13.94 -21.8 33.3 13.34 33.3...
Page 397
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (14HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 26.9 14.67 26.9 14.67 26.7 13.87 26.7 14.67 26.7 14.67 26.2 14.67 -21.8 32.7 14.67 32.7 14.67 32.5...
Page 398
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (14HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 26.7 11.66 26.7 11.75 26.5 11.93 26.5 12.20 26.5 11.63 26.0 11.09 -21.8 30.9 11.93 30.9 12.02 30.7...
Page 399
Multi V 5 Outdoor Units 7. Capacity Tables ARUM160LTE5 Heating Capacity (16HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 28.7 14.80 28.7 15.08 28.5 15.32 28.5 15.69 28.5 16.03 28.5 16.59 -21.8 35.2 15.36 35.2...
Page 400
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (16HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 28.2 16.89 28.2 17.04 28.0 16.61 28.0 17.43 28.0 17.60 28.0 17.68 -21.8 34.6 17.12 34.6 17.28 34.4...
Page 401
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (16HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 28.0 13.53 28.0 13.71 27.8 14.08 27.8 14.63 27.8 13.98 27.8 13.38 -21.8 34.1 14.08 34.4 14.26 34.1...
Page 402
Multi V 5 Outdoor Units 7. Capacity Tables ARUM180LTE5 Heating Capacity (18HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 37.3 17.62 37.3 17.73 37.0 17.83 37.0 17.98 37.0 18.13 36.3 18.36 -21.8 44.2 17.85 44.2...
Page 403
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (18HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 36.6 18.53 36.6 18.59 36.4 17.83 36.4 18.73 36.4 18.80 35.7 18.83 -21.8 43.5 18.62 43.5 18.68 43.2...
Page 404
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (18HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 36.3 15.13 36.3 15.20 36.1 15.36 36.1 15.59 36.1 14.83 34.5 14.12 -21.8 39.8 15.36 39.8 15.43 39.5...
Page 405
Multi V 5 Outdoor Units 7. Capacity Tables ARUM200LTE5 Heating Capacity (20HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 39.5 21.22 39.5 21.29 39.2 21.35 39.2 21.44 39.2 21.53 38.5 21.66 -21.8 48.0 21.36 48.0...
Page 406
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (20HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 38.8 23.35 38.8 23.18 38.6 21.35 38.6 22.74 38.6 22.56 37.8 22.47 -21.8 47.2 23.09 47.2 22.91 46.9...
Page 407
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (20HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 38.5 18.26 38.5 18.31 38.3 18.40 38.3 18.53 38.3 17.66 37.5 16.84 -21.8 44.2 18.40 44.2 18.44 43.9...
Page 408
Multi V 5 Outdoor Units 7. Capacity Tables ARUM220LTE5 Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 43.4 24.18 43.4 24.26 43.2 24.33 43.2 24.44 43.2 24.54 42.3 24.70 -21.8 52.8 24.34 52.8...
Page 409
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 42.7 26.62 42.7 26.42 42.4 24.35 42.4 25.94 42.4 25.73 41.6 25.63 -21.8 51.9 26.33 51.9 26.13 51.6...
Page 410
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 42.4 20.82 42.4 20.87 42.1 20.98 42.1 21.14 42.1 20.15 41.3 19.21 -21.8 48.6 20.98 48.6 21.04 48.3...
Page 411
Multi V 5 Outdoor Units 7. Capacity Tables ARUM240LTE5 Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 45.4 25.72 45.4 25.93 45.1 26.11 45.1 26.38 45.1 26.65 44.3 27.07 -21.8 56.0 26.13 56.0...
Page 412
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 44.7 28.98 44.7 28.88 44.4 26.94 44.4 28.62 44.4 28.51 43.5 28.46 -21.8 55.0 28.82 55.0 28.72 54.7...
Page 413
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 44.3 22.77 44.3 22.91 44.0 23.19 44.0 23.61 44.0 22.50 43.2 21.46 -21.8 52.1 23.19 52.1 23.33 51.8...
Page 414
Multi V 5 Outdoor Units 7. Capacity Tables ARUM260LTE5 Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 46.6 26.20 46.6 26.41 46.3 26.59 46.3 26.88 46.3 27.14 45.4 27.57 -21.8 56.6 26.62 56.6...
Page 415
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 45.8 29.52 45.8 29.41 45.5 27.44 45.5 29.15 45.5 29.04 44.6 28.99 -21.8 55.7 29.36 55.7 29.25 55.3...
Page 416
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 45.4 23.20 45.4 23.34 45.1 23.62 45.1 24.05 45.1 22.92 44.3 21.86 -21.8 52.1 23.62 52.1 23.76 51.8...
Page 417
Multi V 5 Outdoor Units 7. Capacity Tables ARUM221LTE5 Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 44.3 21.1 44.3 21.41 44.0 21.69 44.0 22.10 44.0 22.50 43.4 23.13 -21.8 53.1 21.73 53.1...
Page 418
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 43.5 23.61 43.5 23.76 43.3 22.99 43.3 24.16 43.3 24.33 42.7 24.41 -21.8 52.2 23.85 52.2 24.01 52.0...
Page 419
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 43.2 18.99 43.2 19.19 42.9 19.61 42.9 20.24 42.9 19.18 42.2 18.18 -21.8 48.6 19.61 48.6 19.82 48.2...
Page 420
Multi V 5 Outdoor Units 7. Capacity Tables ARUM241LTE5 Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 47.8 22.9 47.8 23.28 47.6 23.66 47.6 24.22 47.6 24.78 47.4 25.64 -21.8 56.8 23.72 56.8...
Page 421
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 47.0 26.68 47.0 26.84 46.8 25.86 46.8 27.26 46.8 27.44 46.6 27.52 -21.8 55.8 26.94 55.8 27.10 55.6...
Page 422
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 46.6 21.06 46.6 21.34 46.4 21.92 46.4 22.78 46.4 21.62 46.0 20.52 -21.8 53.0 21.92 53.0 22.20 52.6...
Page 423
Multi V 5 Outdoor Units 7. Capacity Tables ARUM261LTE5 Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 51.2 24.5 51.2 24.84 51.0 25.15 51.0 25.61 51.0 26.06 50.3 26.76 -21.8 61.7 25.20 61.7...
Page 424
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 50.4 28.01 50.4 28.09 50.1 26.80 50.1 28.30 50.1 28.39 49.5 28.43 -21.8 60.6 28.14 60.6 28.22 60.3...
Page 425
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 50.0 22.19 50.0 22.42 49.7 22.89 49.7 23.59 49.7 22.44 49.0 21.35 -21.8 57.4 22.89 57.4 23.12 57.0...
Page 426
Multi V 5 Outdoor Units 7. Capacity Tables ARUM280LTE5 Heating Capacity (28HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 52.6 26.2 52.6 26.72 52.3 27.15 52.3 27.80 52.3 28.42 52.2 29.41 -21.8 63.6 27.22 63.6...
Page 427
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (28HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 51.7 30.23 51.7 30.46 51.4 29.54 51.4 31.06 51.4 31.32 51.3 31.44 -21.8 62.5 30.59 62.5 30.83 62.2...
Page 428
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (28HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 51.3 24.06 51.3 24.38 51.0 25.04 51.0 26.02 51.0 24.79 50.8 23.64 -21.8 60.6 25.04 60.9 25.36 60.4...
Page 429
Multi V 5 Outdoor Units 7. Capacity Tables ARUM300LTE5 Heating Capacity (30HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 61.2 29.1 61.2 29.37 60.8 29.66 60.8 30.09 60.8 30.52 60.0 31.18 -21.8 72.6 29.71 72.6...
Page 430
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (30HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 60.1 31.87 60.1 32.01 59.8 30.76 59.8 32.36 59.8 32.52 59.0 32.59 -21.8 71.4 32.09 71.4 32.23 71.0...
Page 431
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (30HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 59.6 25.66 59.6 25.87 59.3 26.32 59.3 26.98 59.3 25.64 57.5 24.38 -21.8 66.3 26.32 66.3 26.53 65.8...
Page 432
Multi V 5 Outdoor Units 7. Capacity Tables ARUM320LTE5 Heating Capacity (32HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 63.4 32.7 63.4 32.93 63.0 33.18 63.0 33.55 63.0 33.92 62.2 34.48 -21.8 76.4 33.22 76.4...
Page 433
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (32HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 62.3 36.69 62.3 36.60 62.0 34.28 62.0 36.37 62.0 36.28 61.1 36.23 -21.8 75.1 36.56 75.1 36.46 74.7...
Page 434
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (32HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 61.8 28.79 61.8 28.98 61.5 29.36 61.5 29.92 61.5 28.47 60.5 27.10 -21.8 70.7 29.36 70.7 29.54 70.2...
Page 435
Multi V 5 Outdoor Units 7. Capacity Tables ARUM340LTE5 Heating Capacity (34HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 67.3 35.6 67.3 35.90 67.0 36.16 67.0 36.55 67.0 36.93 66.0 37.52 -21.8 81.2 36.20 81.2...
Page 436
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (34HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 66.2 39.96 66.2 39.84 65.8 37.28 65.8 39.57 65.8 39.45 64.9 39.39 -21.8 79.8 39.80 79.8 39.68 79.4...
Page 437
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (34HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 65.7 31.35 65.7 31.54 65.3 31.94 65.3 32.53 65.3 30.96 64.3 29.47 -21.8 75.1 31.94 75.1 32.14 74.6...
Page 438
Multi V 5 Outdoor Units 7. Capacity Tables ARUM360LTE5 Heating Capacity (36HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 69.3 37.2 69.3 37.57 68.9 37.94 68.9 38.49 68.9 39.04 68.0 39.89 -21.8 84.4 37.99 84.4...
Page 439
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (36HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 68.2 42.32 68.2 42.30 67.8 39.87 67.8 42.25 67.8 42.23 66.8 42.22 -21.8 82.9 42.29 82.9 42.27 82.5...
Page 440
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (36HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 67.6 33.30 67.6 33.58 67.2 34.15 67.2 35.00 67.2 33.31 66.2 31.72 -21.8 78.6 34.15 78.6 34.43 78.1...
Page 441
Multi V 5 Outdoor Units 7. Capacity Tables ARUM380LTE5 Heating Capacity (38HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 72.7 38.8 72.7 39.13 72.3 39.43 72.3 39.88 72.3 40.32 70.9 41.01 -21.8 89.3 39.47 89.3...
Page 442
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (38HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 71.6 43.65 71.6 43.55 71.1 40.81 71.1 43.29 71.1 43.18 69.7 43.13 -21.8 87.7 43.49 87.7 43.39 87.2...
Page 443
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (38HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 71.0 34.43 71.0 34.66 70.5 35.12 70.5 35.81 70.5 34.13 69.2 32.55 -21.8 83.0 35.12 83.0 35.35 82.5...
Page 444
Multi V 5 Outdoor Units 7. Capacity Tables ARUM400LTE5 Heating Capacity (40HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 74.1 40.5 74.1 41.01 73.6 41.43 73.6 42.07 73.6 42.68 72.8 43.66 -21.8 91.2 41.49 91.2...
Page 445
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (40HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 72.9 45.87 72.9 45.92 72.4 43.55 72.4 46.05 72.4 46.11 71.5 46.14 -21.8 89.6 45.94 89.6 46.00 89.1...
Page 446
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (40HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 72.3 36.30 72.3 36.62 71.8 37.27 71.8 38.24 71.8 36.48 71.0 34.84 -21.8 86.2 37.27 86.5 37.59 85.9...
Page 447
Multi V 5 Outdoor Units 7. Capacity Tables ARUM420LTE5 Heating Capacity (42HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 82.7 43.3 82.7 43.66 82.1 43.94 82.1 44.36 82.1 44.78 80.6 45.43 -21.8 100.2 43.98 100.2...
Page 448
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (42HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 81.3 47.51 81.3 47.47 80.8 44.77 80.8 47.35 80.8 47.31 79.2 47.29 -21.8 98.5 47.44 98.5 47.40 97.9...
Page 449
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (42HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 80.6 37.90 80.6 38.11 80.1 38.55 80.1 39.20 80.1 37.33 77.7 35.58 -21.8 91.9 38.55 91.9 38.76 91.3...
Page 450
Multi V 5 Outdoor Units 7. Capacity Tables ARUM440LTE5 Heating Capacity (44HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 84.9 46.9 84.9 47.22 84.3 47.46 84.3 47.82 84.3 48.18 82.8 48.73 -21.8 104.0 47.49 104.0...
Page 451
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (44HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 83.5 52.33 83.5 52.06 83.0 48.29 83.0 51.36 83.0 51.07 81.3 50.93 -21.8 102.2 51.91 102.2 51.63 101.6...
Page 452
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (44HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 82.8 41.03 82.8 41.22 82.3 41.59 82.3 42.14 82.3 40.16 80.7 38.30 -21.8 96.3 41.59 96.3 41.77 95.7...
Page 453
Multi V 5 Outdoor Units 7. Capacity Tables ARUM460LTE5 Heating Capacity (46HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 88.8 49.9 88.8 50.19 88.3 50.44 88.3 50.82 88.3 51.19 86.6 51.77 -21.8 108.8 50.47 108.8...
Page 454
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (46HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 87.4 55.60 87.4 55.30 86.8 51.29 86.8 54.56 86.8 54.24 85.1 54.09 -21.8 106.9 55.15 106.9 54.85 106.3...
Page 455
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (46HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 86.7 43.59 86.7 43.78 86.1 44.17 86.1 44.75 86.1 42.65 84.5 40.67 -21.8 100.7 44.17 100.7 44.37 100.1...
Page 456
Multi V 5 Outdoor Units 7. Capacity Tables ARUM480LTE5 Heating Capacity (48HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 90.8 51.4 90.8 51.86 90.2 52.22 90.2 52.76 90.2 53.30 88.6 54.14 -21.8 112.0 52.26 112.0...
Page 457
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (48HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 89.4 57.96 89.4 57.76 88.8 53.88 88.8 57.24 88.8 57.02 87.0 56.92 -21.8 110.0 57.64 110.0 57.44 109.4...
Page 458
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (48HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 88.6 45.54 88.6 45.82 88.0 46.38 88.0 47.22 88.0 45.00 86.4 42.92 -21.8 104.2 46.38 104.2 46.66 103.6...
Page 459
Multi V 5 Outdoor Units 7. Capacity Tables ARUM500LTE5 Heating Capacity (50HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 96.6 50.2 96.6 50.77 96.1 51.26 96.1 51.99 96.1 52.71 94.6 53.83 -21.8 117.7 51.33 117.7...
Page 460
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (50HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 95.1 56.99 95.1 56.97 94.5 53.74 94.5 56.92 94.5 56.90 93.0 56.89 -21.8 115.6 56.96 115.6 56.94 115.0...
Page 461
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (50HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 94.3 44.96 94.3 45.33 93.7 46.08 93.7 47.20 93.7 44.94 92.2 42.81 -21.8 109.5 46.08 109.5 46.45 108.8...
Page 462
Multi V 5 Outdoor Units 7. Capacity Tables ARUM520LTE5 Heating Capacity (52HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 98.0 52.0 98.0 52.65 97.4 53.26 97.4 54.18 97.4 55.07 96.5 56.48 -21.8 119.6 53.35 119.6...
Page 463
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (52HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 96.4 59.21 96.4 59.34 95.8 56.48 95.8 59.68 95.8 59.83 94.8 59.90 -21.8 117.5 59.41 117.5 59.55 116.9...
Page 464
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (52HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 95.6 46.83 95.6 47.29 95.0 48.23 95.0 49.63 95.0 47.29 94.0 45.10 -21.8 112.7 48.23 113.0 48.69 112.2...
Page 465
Multi V 5 Outdoor Units 7. Capacity Tables ARUM540LTE5 Heating Capacity (54HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 106.6 54.8 106.6 55.30 105.9 55.77 105.9 56.47 105.9 57.17 104.3 58.25 -21.8 128.6 55.84 128.6...
Page 466
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (54HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 104.8 60.85 104.8 60.89 104.2 57.70 104.2 60.98 104.2 61.03 102.5 61.05 -21.8 126.4 60.91 126.4 60.95 125.7...
Page 467
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (54HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 103.9 48.43 103.9 48.78 103.3 49.51 103.3 50.59 103.3 48.14 100.7 45.84 -21.8 118.4 49.51 118.4 49.86 117.6...
Page 468
Multi V 5 Outdoor Units 7. Capacity Tables ARUM560LTE5 Heating Capacity (56HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 108.8 58.4 108.8 58.86 108.1 59.29 108.1 59.93 108.1 60.57 106.5 61.55 -21.8 132.4 59.35 132.4...
Page 469
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (56HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 107.0 65.67 107.0 65.48 106.4 61.22 106.4 64.99 106.4 64.79 104.6 64.69 -21.8 130.1 65.38 130.1 65.18 129.4...
Page 470
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (56HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 106.1 51.56 106.1 51.89 105.5 52.55 105.5 53.53 105.5 50.97 103.7 48.56 -21.8 122.8 52.55 122.8 52.87 122.0...
Page 471
Multi V 5 Outdoor Units 7. Capacity Tables ARUM580LTE5 Heating Capacity (58HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 112.7 61.3 112.7 61.83 112.1 62.27 112.1 62.93 112.1 63.58 110.3 64.59 -21.8 137.2 62.33 137.2...
Page 472
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (58HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 110.9 68.94 110.9 68.72 110.2 64.22 110.2 68.19 110.2 67.96 108.4 67.85 -21.8 134.8 68.62 134.8 68.40 134.1...
Page 473
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (58HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 110.0 54.12 110.0 54.45 109.3 55.13 109.3 56.14 109.3 53.46 107.5 50.93 -21.8 127.2 55.13 127.2 55.47 126.4...
Page 474
Multi V 5 Outdoor Units 7. Capacity Tables ARUM600LTE5 Heating Capacity (60HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 114.7 62.9 114.7 63.50 114.0 64.05 114.0 64.87 114.0 65.69 112.3 66.96 -21.8 140.4 64.12 140.4...
Page 475
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (60HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 112.9 71.30 112.9 71.18 112.2 66.81 112.2 70.87 112.2 70.74 110.3 70.68 -21.8 137.9 71.11 137.9 70.99 137.2...
Page 476
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (60HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 111.9 56.07 111.9 56.49 111.2 57.34 111.2 58.61 111.2 55.81 109.4 53.18 -21.8 130.7 57.34 130.7 57.76 129.9...
Page 477
Multi V 5 Outdoor Units 7. Capacity Tables ARUM620LTE5 Heating Capacity (62HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 118.1 64.5 118.1 65.06 117.4 65.54 117.4 66.26 117.4 66.97 115.2 68.08 -21.8 145.3 65.60 145.3...
Page 478
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (62HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 116.3 72.63 116.3 72.43 115.5 67.75 115.5 71.91 115.5 71.69 113.2 71.59 -21.8 142.7 72.31 142.7 72.11 141.9...
Page 479
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (62HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 115.3 57.20 115.3 57.57 114.5 58.31 114.5 59.42 114.5 56.63 112.4 54.01 -21.8 135.1 58.31 135.1 58.68 134.3...
Page 480
Multi V 5 Outdoor Units 7. Capacity Tables ARUM640LTE5 Heating Capacity (64HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 119.5 66.2 119.5 66.94 118.7 67.54 118.7 68.45 118.7 69.33 117.1 70.73 -21.8 147.2 67.62 147.2...
Page 481
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (64HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 117.6 74.85 117.6 74.80 116.8 70.49 116.8 74.67 116.8 74.62 115.0 74.60 -21.8 144.6 74.76 144.6 74.72 143.8...
Page 482
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (64HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 116.6 59.07 116.6 59.53 115.8 60.46 115.8 61.85 115.8 58.98 114.2 56.30 -21.8 138.3 60.46 138.6 60.92 137.7...
Page 483
Multi V 5 Outdoor Units 7. Capacity Tables ARUM660LTE5 Heating Capacity (66HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 128.1 69.1 128.1 69.59 127.2 70.05 127.2 70.74 127.2 71.43 124.9 72.50 -21.8 156.2 70.11 156.2...
Page 484
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (66HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 126.0 76.49 126.0 76.35 125.2 71.71 125.2 75.97 125.2 75.82 122.7 75.75 -21.8 153.5 76.26 153.5 76.12 152.6...
Page 485
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (66HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 124.9 60.67 124.9 61.02 124.1 61.74 124.1 62.81 124.1 59.83 120.9 57.04 -21.8 144.0 61.74 144.0 62.09 143.1...
Page 486
Multi V 5 Outdoor Units 7. Capacity Tables ARUM680LTE5 Heating Capacity (68HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 130.3 72.7 130.3 73.15 129.4 73.57 129.4 74.20 129.4 74.83 127.1 75.80 -21.8 160.0 73.62 160.0...
Page 487
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (68HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 128.2 81.31 128.2 80.94 127.4 75.23 127.4 79.98 127.4 79.58 124.8 79.39 -21.8 157.2 80.73 157.2 80.35 156.3...
Page 488
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (68HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 127.1 63.80 127.1 64.13 126.3 64.78 126.3 65.75 126.3 62.66 123.9 59.76 -21.8 148.4 64.78 148.4 65.10 147.5...
Page 489
Multi V 5 Outdoor Units 7. Capacity Tables ARUM700LTE5 Heating Capacity (70HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 134.2 75.6 134.2 76.12 133.4 76.55 133.4 77.20 133.4 77.84 130.9 78.84 -21.8 164.8 76.60 164.8...
Page 490
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (70HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 132.1 84.58 132.1 84.18 131.2 78.23 131.2 83.18 131.2 82.75 128.6 82.55 -21.8 161.9 83.97 161.9 83.57 161.0...
Page 491
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (70HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 131.0 66.36 131.0 66.69 130.1 67.36 130.1 68.36 130.1 65.15 127.7 62.13 -21.8 152.8 67.36 152.8 67.70 151.9...
Page 492
Multi V 5 Outdoor Units 7. Capacity Tables ARUM720LTE5 Heating Capacity (72HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 136.2 77.2 136.2 77.79 135.3 78.33 135.3 79.14 135.3 79.95 132.9 81.21 -21.8 168.0 78.39 168.0...
Page 493
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (72HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 134.1 86.94 134.1 86.64 133.2 80.82 133.2 85.86 133.2 85.53 130.5 85.38 -21.8 165.0 86.46 165.0 86.16 164.1...
Page 494
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (72HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 132.9 68.31 132.9 68.73 132.0 69.57 132.0 70.83 132.0 67.50 129.6 64.38 -21.8 156.3 69.57 156.3 69.99 155.4...
Page 495
Multi V 5 Outdoor Units 7. Capacity Tables ARUM740LTE5 Heating Capacity (74HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 142.0 75.9 142.0 76.70 141.2 77.37 141.2 78.37 141.2 79.36 138.9 80.90 -21.8 173.7 77.46 173.7...
Page 496
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (74HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 139.8 85.97 139.8 85.85 138.9 80.68 138.9 85.54 138.9 85.41 136.5 85.35 -21.8 170.6 85.78 170.6 85.66 169.7...
Page 497
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (74HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 138.6 67.73 138.6 68.24 137.7 69.27 137.7 70.81 137.7 67.44 135.4 64.27 -21.8 161.6 69.27 161.6 69.78 160.6...
Page 498
Multi V 5 Outdoor Units 7. Capacity Tables ARUM760LTE5 Heating Capacity (76HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 143.4 77.7 143.4 78.58 142.5 79.37 142.5 80.56 142.5 81.72 140.8 83.55 -21.8 175.6 79.48 175.6...
Page 499
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (76HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 141.1 88.19 141.1 88.22 140.2 83.42 140.2 88.30 140.2 88.34 138.3 88.36 -21.8 172.5 88.23 172.5 88.27 171.6...
Page 500
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (76HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 139.9 69.60 139.9 70.20 139.0 71.42 139.0 73.24 139.0 69.79 137.2 66.56 -21.8 164.8 71.42 165.1 72.02 164.0...
Page 501
Multi V 5 Outdoor Units 7. Capacity Tables ARUM780LTE5 Heating Capacity (78HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 152.0 80.5 152.0 81.23 151.0 81.88 151.0 82.85 151.0 83.82 148.6 85.32 -21.8 184.6 81.97 184.6...
Page 502
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (78HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 149.5 89.83 149.5 89.77 148.6 84.64 148.6 89.60 148.6 89.54 146.0 89.51 -21.8 181.4 89.73 181.4 89.67 180.4...
Page 503
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (78HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 148.2 71.20 148.2 71.69 147.3 72.70 147.3 74.20 147.3 70.64 143.9 67.30 -21.8 170.5 72.70 170.5 73.19 169.4...
Page 504
Multi V 5 Outdoor Units 7. Capacity Tables ARUM800LTE5 Heating Capacity (80HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 154.2 84.1 154.2 84.79 153.2 85.40 153.2 86.31 153.2 87.22 150.8 88.62 -21.8 188.4 85.48 188.4...
Page 505
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (80HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 151.7 94.65 151.7 94.36 150.8 88.16 150.8 93.61 150.8 93.30 148.1 93.15 -21.8 185.1 94.20 185.1 93.90 184.1...
Page 506
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (80HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 150.4 74.33 150.4 74.80 149.5 75.74 149.5 77.14 149.5 73.47 146.9 70.02 -21.8 174.9 75.74 174.9 76.20 173.8...
Page 507
Multi V 5 Outdoor Units 7. Capacity Tables ARUM820LTE5 Heating Capacity (82HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 158.1 87.1 158.1 87.76 157.2 88.38 157.2 89.31 157.2 90.23 154.6 91.66 -21.8 193.2 88.46 193.2...
Page 508
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (82HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 155.6 97.92 155.6 97.60 154.6 91.16 154.6 96.81 154.6 96.47 151.9 96.31 -21.8 189.8 97.44 189.8 97.12 188.8...
Page 509
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (82HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 154.3 76.89 154.3 77.36 153.3 78.32 153.3 79.75 153.3 75.96 150.7 72.39 -21.8 179.3 78.32 179.3 78.80 178.2...
Page 510
Multi V 5 Outdoor Units 7. Capacity Tables ARUM840LTE5 Heating Capacity (84HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 160.1 88.6 160.1 89.43 159.1 90.16 159.1 91.25 159.1 92.34 156.6 94.03 -21.8 196.4 90.25 196.4...
Page 511
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (84HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 157.6 100.28 157.6 100.06 156.6 93.75 156.6 99.49 156.6 99.25 153.8 99.14 -21.8 192.9 99.93 192.9 99.71 191.9...
Page 512
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (84HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 156.2 78.84 156.2 79.40 155.2 80.53 155.2 82.22 155.2 78.31 152.6 74.64 -21.8 182.8 80.53 182.8 81.09 181.7...
Page 513
Multi V 5 Outdoor Units 7. Capacity Tables ARUM860LTE5 Heating Capacity (86HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 163.5 90.2 163.5 90.99 162.5 91.65 162.5 92.64 162.5 93.62 159.5 95.15 -21.8 201.3 91.73 201.3...
Page 514
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (86HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 161.0 101.61 161.0 101.31 159.9 94.69 159.9 100.53 159.9 100.20 156.7 100.05 -21.8 197.7 101.13 197.7 100.83 196.6...
Page 515
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (86HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 159.6 79.97 159.6 80.48 158.5 81.50 158.5 83.03 158.5 79.13 155.6 75.47 -21.8 187.2 81.50 187.2 82.01 186.1...
Page 516
Multi V 5 Outdoor Units 7. Capacity Tables ARUM880LTE5 Heating Capacity (88HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 164.9 92.0 164.9 92.87 163.8 93.65 163.8 94.83 163.8 95.98 161.4 97.80 -21.8 203.2 93.75 203.2...
Page 517
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (88HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 162.3 103.8 162.3 103.7 161.2 97.43 161.2 103.3 161.2 103.1 158.5 103.1 -21.8 199.6 103.6 199.6 103.4 198.5...
Page 518
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (88HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 160.9 81.84 160.9 82.44 159.8 83.65 159.8 85.46 159.8 81.48 157.4 77.76 -21.8 190.4 83.65 190.7 84.25 189.5...
Page 519
Multi V 5 Outdoor Units 7. Capacity Tables ARUM900LTE5 Heating Capacity (90HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 173.5 94.8 173.5 95.52 172.3 96.16 172.3 97.12 172.3 98.08 169.2 99.57 -21.8 212.2 96.24 212.2...
Page 520
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (90HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 170.7 105.5 170.7 105.2 169.6 98.65 169.6 104.6 169.6 104.3 166.2 104.2 -21.8 208.5 105.1 208.5 104.8 207.3...
Page 521
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (90HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 169.2 83.44 169.2 83.93 168.1 84.93 168.1 86.42 168.1 82.33 164.1 78.50 -21.8 196.1 84.93 196.1 85.42 194.9...
Page 522
Multi V 5 Outdoor Units 7. Capacity Tables ARUM920LTE5 Heating Capacity (92HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 175.7 98.4 175.7 99.08 174.5 99.68 174.5 100.6 174.5 101.5 171.4 102.9 -21.8 216.0 99.75 216.0...
Page 523
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (92HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 172.9 110.3 172.9 109.8 171.8 102.2 171.8 108.6 171.8 108.1 168.3 107.9 -21.8 212.2 109.6 212.2 109.1 211.0...
Page 524
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (92HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 171.4 86.57 171.4 87.04 170.3 87.97 170.3 89.36 170.3 85.16 167.1 81.22 -21.8 200.5 87.97 200.5 88.43 199.3...
Page 525
Multi V 5 Outdoor Units 7. Capacity Tables ARUM940LTE5 Heating Capacity (94HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 179.6 101.3 179.6 102.1 178.5 102.7 178.5 103.6 178.5 104.5 175.2 105.9 -21.8 220.8 102.7 220.8...
Page 526
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (94HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 176.8 113.6 176.8 113.1 175.6 105.2 175.6 111.8 175.6 111.3 172.1 111.0 -21.8 216.9 112.8 216.9 112.3 215.7...
Page 527
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (94HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 175.3 89.13 175.3 89.60 174.1 90.55 174.1 91.97 174.1 87.65 170.9 83.59 -21.8 204.9 90.55 204.9 91.03 203.7...
Page 528
Multi V 5 Outdoor Units 7. Capacity Tables ARUM960LTE5 Heating Capacity (96HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 181.6 102.9 181.6 103.7 180.4 104.4 180.4 105.5 180.4 106.6 177.2 108.3 -21.8 224.0 104.5 224.0...
Page 529
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (96HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 178.8 115.9 178.8 115.5 177.6 107.8 177.6 114.5 177.6 114.0 174.0 113.8 -21.8 220.0 115.3 220.0 114.9 218.8...
Page 530
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (96HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 177.2 91.08 177.2 91.64 176.0 92.76 176.0 94.44 176.0 90.00 172.8 85.84 -21.8 208.4 92.76 208.4 93.32 207.2...
Page 531
Multi V 5 Outdoor Units 7. Capacity Tables 7.2.2 SLC Mode ARUM080LTE5 Heating Capacity (8HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 15.6 7.34 15.6 7.39 15.5 7.43 15.5 7.50 15.5 7.56 15.2...
Page 532
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (8HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 15.4 8.23 15.4 8.19 15.3 7.60 15.3 8.09 15.3 8.05 15.0 8.03 -21.8 18.7 8.17 18.7 8.13 18.6...
Page 533
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (8HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 15.2 6.45 15.2 6.48 15.1 6.55 15.1 6.65 15.1 6.30 14.8 5.99 -21.8 17.7 6.55 17.7 6.58 17.6...
Page 534
Multi V 5 Outdoor Units 7. Capacity Tables ARUM100LTE5 Heating Capacity (10HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 20.4 9.67 20.4 9.77 20.2 9.86 20.2 9.99 20.2 10.11 19.7 10.31 -21.8 24.7 9.87 24.7...
Page 535
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (10HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 20.0 10.27 20.0 10.34 19.9 10.06 19.9 10.53 19.9 10.61 19.4 10.65 -21.8 24.3 10.38 24.3 10.46 24.2...
Page 536
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (10HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 19.9 8.46 19.9 8.52 19.7 8.65 19.7 8.85 19.7 8.37 19.2 7.92 -21.8 22.1 8.65 22.1 8.72 21.9...
Page 537
Multi V 5 Outdoor Units 7. Capacity Tables ARUM120LTE5 Heating Capacity (12HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 23.9 11.43 23.9 11.64 23.8 11.83 23.8 12.11 23.8 12.39 23.7 12.82 -21.8 28.4 11.86 28.4...
Page 538
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (12HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 23.5 13.34 23.5 13.42 23.4 12.93 23.4 13.63 23.4 13.72 23.3 13.76 -21.8 27.9 13.47 27.9 13.55 27.8...
Page 539
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (12HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 23.3 10.53 23.3 10.67 23.2 10.96 23.2 11.39 23.2 10.81 23.0 10.26 -21.8 26.5 10.96 26.5 11.10 26.3...
Page 540
Multi V 5 Outdoor Units 7. Capacity Tables ARUM140LTE5 Heating Capacity (14HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 27.3 13.07 27.3 13.20 27.2 13.32 27.2 13.50 27.2 13.67 26.6 13.94 -21.8 33.3 13.34 33.3...
Page 541
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (14HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 26.9 14.67 26.9 14.67 26.7 13.87 26.7 14.67 26.7 14.67 26.2 14.67 -21.8 32.7 14.67 32.7 14.67 32.5...
Page 542
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (14HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 26.7 11.66 26.7 11.75 26.5 11.93 26.5 12.20 26.5 11.63 26.0 11.09 -21.8 30.9 11.93 30.9 12.02 30.7...
Page 543
Multi V 5 Outdoor Units 7. Capacity Tables ARUM160LTE5 Heating Capacity (16HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 28.7 14.80 28.7 15.08 28.5 15.32 28.5 15.69 28.5 16.03 28.5 16.59 -21.8 35.2 15.36 35.2...
Page 544
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (16HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 28.2 16.89 28.2 17.04 28.0 16.61 28.0 17.43 28.0 17.60 28.0 17.68 -21.8 34.6 17.12 34.6 17.28 34.4...
Page 545
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (16HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 28.0 13.53 28.0 13.71 27.8 14.08 27.8 14.63 27.8 13.98 27.8 13.38 -21.8 34.1 14.08 34.4 14.26 34.1...
Page 546
Multi V 5 Outdoor Units 7. Capacity Tables ARUM180LTE5 Heating Capacity (18HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 37.3 17.62 37.3 17.73 37.0 17.83 37.0 17.98 37.0 18.13 36.3 18.36 -21.8 44.2 17.85 44.2...
Page 547
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (18HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 36.6 18.53 36.6 18.59 36.4 17.83 36.4 18.73 36.4 18.80 35.7 18.83 -21.8 43.5 18.62 43.5 18.68 43.2...
Page 548
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (18HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 36.3 15.13 36.3 15.20 36.1 15.36 36.1 15.59 36.1 14.83 34.5 14.12 -21.8 39.8 15.36 39.8 15.43 39.5...
Page 549
Multi V 5 Outdoor Units 7. Capacity Tables ARUM200LTE5 Heating Capacity (20HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 39.5 21.22 39.5 21.29 39.2 21.35 39.2 21.44 39.2 21.53 38.5 21.66 -21.8 48.0 21.36 48.0...
Page 550
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (20HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 38.8 23.35 38.8 23.18 38.6 21.35 38.6 22.74 38.6 22.56 37.8 22.47 -21.8 47.2 23.09 47.2 22.91 46.9...
Page 551
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (20HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 38.5 18.26 38.5 18.31 38.3 18.40 38.3 18.53 38.3 17.66 37.5 16.84 -21.8 44.2 18.40 44.2 18.44 43.9...
Page 552
Multi V 5 Outdoor Units 7. Capacity Tables ARUM220LTE5 Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 43.4 24.18 43.4 24.26 43.2 24.33 43.2 24.44 43.2 24.54 42.3 24.70 -21.8 52.8 24.34 52.8...
Page 553
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 42.7 26.62 42.7 26.42 42.4 24.35 42.4 25.94 42.4 25.73 41.6 25.63 -21.8 51.9 26.33 51.9 26.13 51.6...
Page 554
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 42.4 20.82 42.4 20.87 42.1 20.98 42.1 21.14 42.1 20.15 41.3 19.21 -21.8 48.6 20.98 48.6 21.04 48.3...
Page 555
Multi V 5 Outdoor Units 7. Capacity Tables ARUM240LTE5 Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 45.4 25.72 45.4 25.93 45.1 26.11 45.1 26.38 45.1 26.65 44.3 27.07 -21.8 56.0 26.13 56.0...
Page 556
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 44.7 28.98 44.7 28.88 44.4 26.94 44.4 28.62 44.4 28.51 43.5 28.46 -21.8 55.0 28.82 55.0 28.72 54.7...
Page 557
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 44.3 22.77 44.3 22.91 44.0 23.19 44.0 23.61 44.0 22.50 43.2 21.46 -21.8 52.1 23.19 52.1 23.33 51.8...
Page 558
Multi V 5 Outdoor Units 7. Capacity Tables ARUM260LTE5 Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 46.6 26.20 46.6 26.41 46.3 26.59 46.3 26.88 46.3 27.14 45.4 27.57 -21.8 56.6 26.62 56.6...
Page 559
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 45.8 29.52 45.8 29.41 45.5 27.44 45.5 29.15 45.5 29.04 44.6 28.99 -21.8 55.7 29.36 55.7 29.25 55.3...
Page 560
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 45.4 23.20 45.4 23.34 45.1 23.62 45.1 24.05 45.1 22.92 44.3 21.86 -21.8 52.1 23.62 52.1 23.76 51.8...
Page 561
Multi V 5 Outdoor Units 7. Capacity Tables ARUM221LTE5 Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 44.3 21.1 44.3 21.41 44.0 21.69 44.0 22.10 44.0 22.50 43.4 23.13 -21.8 53.1 21.73 53.1...
Page 562
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 43.5 23.61 43.5 23.76 43.3 22.99 43.3 24.16 43.3 24.33 42.7 24.41 -21.8 52.2 23.85 52.2 24.01 52.0...
Page 563
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (22HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 43.2 18.99 43.2 19.19 42.9 19.61 42.9 20.24 42.9 19.18 42.2 18.18 -21.8 48.6 19.61 48.6 19.82 48.2...
Page 564
Multi V 5 Outdoor Units 7. Capacity Tables ARUM241LTE5 Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 47.8 22.9 47.8 23.28 47.6 23.66 47.6 24.22 47.6 24.78 47.4 25.64 -21.8 56.8 23.72 56.8...
Page 565
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 47.0 26.68 47.0 26.84 46.8 25.86 46.8 27.26 46.8 27.44 46.6 27.52 -21.8 55.8 26.94 55.8 27.10 55.6...
Page 566
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (24HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 46.6 21.06 46.6 21.34 46.4 21.92 46.4 22.78 46.4 21.62 46.0 20.52 -21.8 53.0 21.92 53.0 22.20 52.6...
Page 567
Multi V 5 Outdoor Units 7. Capacity Tables ARUM261LTE5 Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 51.2 24.5 51.2 24.84 51.0 25.15 51.0 25.61 51.0 26.06 50.3 26.76 -21.8 61.7 25.20 61.7...
Page 568
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 50.4 28.01 50.4 28.09 50.1 26.80 50.1 28.30 50.1 28.39 49.5 28.43 -21.8 60.6 28.14 60.6 28.22 60.3...
Page 569
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (26HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 50.0 22.19 50.0 22.42 49.7 22.89 49.7 23.59 49.7 22.44 49.0 21.35 -21.8 57.4 22.89 57.4 23.12 57.0...
Page 570
Multi V 5 Outdoor Units 7. Capacity Tables ARUM280LTE5 Heating Capacity (28HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 52.6 26.2 52.6 26.72 52.3 27.15 52.3 27.80 52.3 28.42 52.2 29.41 -21.8 63.6 27.22 63.6...
Page 571
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (28HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 51.7 30.23 51.7 30.46 51.4 29.54 51.4 31.06 51.4 31.32 51.3 31.44 -21.8 62.5 30.59 62.5 30.83 62.2...
Page 572
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (28HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 51.3 24.06 51.3 24.38 51.0 25.04 51.0 26.02 51.0 24.79 50.8 23.64 -21.8 60.6 25.04 60.9 25.36 60.4...
Page 573
Multi V 5 Outdoor Units 7. Capacity Tables ARUM300LTE5 Heating Capacity (30HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 61.2 29.1 61.2 29.37 60.8 29.66 60.8 30.09 60.8 30.52 60.0 31.18 -21.8 72.6 29.71 72.6...
Page 574
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (30HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 60.1 31.87 60.1 32.01 59.8 30.76 59.8 32.36 59.8 32.52 59.0 32.59 -21.8 71.4 32.09 71.4 32.23 71.0...
Page 575
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (30HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 59.6 25.66 59.6 25.87 59.3 26.32 59.3 26.98 59.3 25.64 57.5 24.38 -21.8 66.3 26.32 66.3 26.53 65.8...
Page 576
Multi V 5 Outdoor Units 7. Capacity Tables ARUM320LTE5 Heating Capacity (32HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 63.4 32.7 63.4 32.93 63.0 33.18 63.0 33.55 63.0 33.92 62.2 34.48 -21.8 76.4 33.22 76.4...
Page 577
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (32HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 62.3 36.69 62.3 36.60 62.0 34.28 62.0 36.37 62.0 36.28 61.1 36.23 -21.8 75.1 36.56 75.1 36.46 74.7...
Page 578
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (32HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 61.8 28.79 61.8 28.98 61.5 29.36 61.5 29.92 61.5 28.47 60.5 27.10 -21.8 70.7 29.36 70.7 29.54 70.2...
Page 579
Multi V 5 Outdoor Units 7. Capacity Tables ARUM340LTE5 Heating Capacity (34HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 67.3 35.6 67.3 35.90 67.0 36.16 67.0 36.55 67.0 36.93 66.0 37.52 -21.8 81.2 36.20 81.2...
Page 580
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (34HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 66.2 39.96 66.2 39.84 65.8 37.28 65.8 39.57 65.8 39.45 64.9 39.39 -21.8 79.8 39.80 79.8 39.68 79.4...
Page 581
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (34HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 65.7 31.35 65.7 31.54 65.3 31.94 65.3 32.53 65.3 30.96 64.3 29.47 -21.8 75.1 31.94 75.1 32.14 74.6...
Page 582
Multi V 5 Outdoor Units 7. Capacity Tables ARUM360LTE5 Heating Capacity (36HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 69.3 37.2 69.3 37.57 68.9 37.94 68.9 38.49 68.9 39.04 68.0 39.89 -21.8 84.4 37.99 84.4...
Page 583
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (36HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 68.2 42.32 68.2 42.30 67.8 39.87 67.8 42.25 67.8 42.23 66.8 42.22 -21.8 82.9 42.29 82.9 42.27 82.5...
Page 584
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (36HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 67.6 33.30 67.6 33.58 67.2 34.15 67.2 35.00 67.2 33.31 66.2 31.72 -21.8 78.6 34.15 78.6 34.43 78.1...
Page 585
Multi V 5 Outdoor Units 7. Capacity Tables ARUM380LTE5 Heating Capacity (38HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 72.7 38.8 72.7 39.13 72.3 39.43 72.3 39.88 72.3 40.32 70.9 41.01 -21.8 89.3 39.47 89.3...
Page 586
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (38HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 71.6 43.65 71.6 43.55 71.1 40.81 71.1 43.29 71.1 43.18 69.7 43.13 -21.8 87.7 43.49 87.7 43.39 87.2...
Page 587
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (38HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 71.0 34.43 71.0 34.66 70.5 35.12 70.5 35.81 70.5 34.13 69.2 32.55 -21.8 83.0 35.12 83.0 35.35 82.5...
Page 588
Multi V 5 Outdoor Units 7. Capacity Tables ARUM400LTE5 Heating Capacity (40HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 74.1 40.5 74.1 41.01 73.6 41.43 73.6 42.07 73.6 42.68 72.8 43.66 -21.8 91.2 41.49 91.2...
Page 589
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (40HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 72.9 45.87 72.9 45.92 72.4 43.55 72.4 46.05 72.4 46.11 71.5 46.14 -21.8 89.6 45.94 89.6 46.00 89.1...
Page 590
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (40HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 72.3 36.30 72.3 36.62 71.8 37.27 71.8 38.24 71.8 36.48 71.0 34.84 -21.8 86.2 37.27 86.5 37.59 85.9...
Page 591
Multi V 5 Outdoor Units 7. Capacity Tables ARUM420LTE5 Heating Capacity (42HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 82.7 43.3 82.7 43.66 82.1 43.94 82.1 44.36 82.1 44.78 80.6 45.43 -21.8 100.2 43.98 100.2...
Page 592
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (42HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 81.3 47.51 81.3 47.47 80.8 44.77 80.8 47.35 80.8 47.31 79.2 47.29 -21.8 98.5 47.44 98.5 47.40 97.9...
Page 593
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (42HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 80.6 37.90 80.6 38.11 80.1 38.55 80.1 39.20 80.1 37.33 77.7 35.58 -21.8 91.9 38.55 91.9 38.76 91.3...
Page 594
Multi V 5 Outdoor Units 7. Capacity Tables ARUM440LTE5 Heating Capacity (44HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 84.9 46.9 84.9 47.22 84.3 47.46 84.3 47.82 84.3 48.18 82.8 48.73 -21.8 104.0 47.49 104.0...
Page 595
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (44HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 83.5 52.33 83.5 52.06 83.0 48.29 83.0 51.36 83.0 51.07 81.3 50.93 -21.8 102.2 51.91 102.2 51.63 101.6...
Page 596
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (44HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 82.8 41.03 82.8 41.22 82.3 41.59 82.3 42.14 82.3 40.16 80.7 38.30 -21.8 96.3 41.59 96.3 41.77 95.7...
Page 597
Multi V 5 Outdoor Units 7. Capacity Tables ARUM460LTE5 Heating Capacity (46HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 88.8 49.9 88.8 50.19 88.3 50.44 88.3 50.82 88.3 51.19 86.6 51.77 -21.8 108.8 50.47 108.8...
Page 598
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (46HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 87.4 55.60 87.4 55.30 86.8 51.29 86.8 54.56 86.8 54.24 85.1 54.09 -21.8 106.9 55.15 106.9 54.85 106.3...
Page 599
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (46HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 86.7 43.59 86.7 43.78 86.1 44.17 86.1 44.75 86.1 42.65 84.5 40.67 -21.8 100.7 44.17 100.7 44.37 100.1...
Page 600
Multi V 5 Outdoor Units 7. Capacity Tables ARUM480LTE5 Heating Capacity (48HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 90.8 51.4 90.8 51.86 90.2 52.22 90.2 52.76 90.2 53.30 88.6 54.14 -21.8 112.0 52.26 112.0...
Page 601
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (48HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 89.4 57.96 89.4 57.76 88.8 53.88 88.8 57.24 88.8 57.02 87.0 56.92 -21.8 110.0 57.64 110.0 57.44 109.4...
Page 602
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (48HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 88.6 45.54 88.6 45.82 88.0 46.38 88.0 47.22 88.0 45.00 86.4 42.92 -21.8 104.2 46.38 104.2 46.66 103.6...
Page 603
Multi V 5 Outdoor Units 7. Capacity Tables ARUM500LTE5 Heating Capacity (50HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 96.6 50.2 96.6 50.77 96.1 51.26 96.1 51.99 96.1 52.71 94.6 53.83 -21.8 117.7 51.33...
Page 604
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (50HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 95.1 56.99 95.1 56.97 94.5 53.74 94.5 56.92 94.5 56.90 93.0 56.89 -21.8 115.6 56.96 115.6 56.94 115.0...
Page 605
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (50HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 94.3 44.96 94.3 45.33 93.7 46.08 93.7 47.20 93.7 44.94 92.2 42.81 -21.8 109.5 46.08 109.5 46.45 108.8...
Page 606
Multi V 5 Outdoor Units 7. Capacity Tables ARUM520LTE5 Heating Capacity (52HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 98.0 52.0 98.0 52.65 97.4 53.26 97.4 54.18 97.4 55.07 96.5 56.48 -21.8 119.6 53.35 119.6...
Page 607
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (52HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 96.4 59.21 96.4 59.34 95.8 56.48 95.8 59.68 95.8 59.83 94.8 59.90 -21.8 117.5 59.41 117.5 59.55 116.9...
Page 608
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (52HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 95.6 46.83 95.6 47.29 95.0 48.23 95.0 49.63 95.0 47.29 94.0 45.10 -21.8 112.7 48.23 113.0 48.69 112.2...
Page 609
Multi V 5 Outdoor Units 7. Capacity Tables ARUM540LTE5 Heating Capacity (54HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 106.6 54.8 106.6 55.30 105.9 55.77 105.9 56.47 105.9 57.17 104.3 58.25 -21.8 128.6 55.84 128.6...
Page 610
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (54HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 104.8 60.85 104.8 60.89 104.2 57.70 104.2 60.98 104.2 61.03 102.5 61.05 -21.8 126.4 60.91 126.4 60.95 125.7...
Page 611
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (54HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 103.9 48.43 103.9 48.78 103.3 49.51 103.3 50.59 103.3 48.14 100.7 45.84 -21.8 118.4 49.51 118.4 49.86 117.6...
Page 612
Multi V 5 Outdoor Units 7. Capacity Tables ARUM560LTE5 Heating Capacity (56HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 108.8 58.4 108.8 58.86 108.1 59.29 108.1 59.93 108.1 60.57 106.5 61.55 -21.8 132.4 59.35 132.4...
Page 613
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (56HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 107.0 65.67 107.0 65.48 106.4 61.22 106.4 64.99 106.4 64.79 104.6 64.69 -21.8 130.1 65.38 130.1 65.18 129.4...
Page 614
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (56HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 106.1 51.56 106.1 51.89 105.5 52.55 105.5 53.53 105.5 50.97 103.7 48.56 -21.8 122.8 52.55 122.8 52.87 122.0...
Page 615
Multi V 5 Outdoor Units 7. Capacity Tables ARUM580LTE5 Heating Capacity (58HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 112.7 61.3 112.7 61.83 112.1 62.27 112.1 62.93 112.1 63.58 110.3 64.59 -21.8 137.2 62.33 137.2...
Page 616
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (58HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 110.9 68.94 110.9 68.72 110.2 64.22 110.2 68.19 110.2 67.96 108.4 67.85 -21.8 134.8 68.62 134.8 68.40 134.1...
Page 617
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (58HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 110.0 54.12 110.0 54.45 109.3 55.13 109.3 56.14 109.3 53.46 107.5 50.93 -21.8 127.2 55.13 127.2 55.47 126.4...
Page 618
Multi V 5 Outdoor Units 7. Capacity Tables ARUM600LTE5 Heating Capacity (60HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 114.7 62.9 114.7 63.50 114.0 64.05 114.0 64.87 114.0 65.69 112.3 66.96 -21.8 140.4 64.12 140.4...
Page 619
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (60HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 112.9 71.30 112.9 71.18 112.2 66.81 112.2 70.87 112.2 70.74 110.3 70.68 -21.8 137.9 71.11 137.9 70.99 137.2...
Page 620
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (60HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 111.9 56.07 111.9 56.49 111.2 57.34 111.2 58.61 111.2 55.81 109.4 53.18 -21.8 130.7 57.34 130.7 57.76 129.9...
Page 621
Multi V 5 Outdoor Units 7. Capacity Tables ARUM620LTE5 Heating Capacity (62HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 118.1 64.5 118.1 65.06 117.4 65.54 117.4 66.26 117.4 66.97 115.2 68.08 -21.8 145.3 65.60 145.3...
Page 622
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (62HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 116.3 72.63 116.3 72.43 115.5 67.75 115.5 71.91 115.5 71.69 113.2 71.59 -21.8 142.7 72.31 142.7 72.11 141.9...
Page 623
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (62HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 115.3 57.20 115.3 57.57 114.5 58.31 114.5 59.42 114.5 56.63 112.4 54.01 -21.8 135.1 58.31 135.1 58.68 134.3...
Page 624
Multi V 5 Outdoor Units 7. Capacity Tables ARUM640LTE5 Heating Capacity (64HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 119.5 66.2 119.5 66.94 118.7 67.54 118.7 68.45 118.7 69.33 117.1 70.73 -21.8 147.2 67.62 147.2...
Page 625
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (64HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 117.6 74.85 117.6 74.80 116.8 70.49 116.8 74.67 116.8 74.62 115.0 74.60 -21.8 144.6 74.76 144.6 74.72 143.8...
Page 626
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (64HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 116.6 59.07 116.6 59.53 115.8 60.46 115.8 61.85 115.8 58.98 114.2 56.30 -21.8 138.3 60.46 138.6 60.92 137.7...
Page 627
Multi V 5 Outdoor Units 7. Capacity Tables ARUM660LTE5 Heating Capacity (66HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 128.1 69.1 128.1 69.59 127.2 70.05 127.2 70.74 127.2 71.43 124.9 72.50 -21.8 156.2 70.11 156.2...
Page 628
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (66HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 126.0 76.49 126.0 76.35 125.2 71.71 125.2 75.97 125.2 75.82 122.7 75.75 -21.8 153.5 76.26 153.5 76.12 152.6...
Page 629
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (66HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 124.9 60.67 124.9 61.02 124.1 61.74 124.1 62.81 124.1 59.83 120.9 57.04 -21.8 144.0 61.74 144.0 62.09 143.1...
Page 630
Multi V 5 Outdoor Units 7. Capacity Tables ARUM680LTE5 Heating Capacity (68HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 130.3 72.7 130.3 73.15 129.4 73.57 129.4 74.20 129.4 74.83 127.1 75.80 -21.8 160.0 73.62 160.0...
Page 631
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (68HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 128.2 81.31 128.2 80.94 127.4 75.23 127.4 79.98 127.4 79.58 124.8 79.39 -21.8 157.2 80.73 157.2 80.35 156.3...
Page 632
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (68HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 127.1 63.80 127.1 64.13 126.3 64.78 126.3 65.75 126.3 62.66 123.9 59.76 -21.8 148.4 64.78 148.4 65.10 147.5...
Page 633
Multi V 5 Outdoor Units 7. Capacity Tables ARUM700LTE5 Heating Capacity (70HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 134.2 75.6 134.2 76.12 133.4 76.55 133.4 77.20 133.4 77.84 130.9 78.84 -21.8 164.8 76.60 164.8...
Page 634
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (70HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 132.1 84.58 132.1 84.18 131.2 78.23 131.2 83.18 131.2 82.75 128.6 82.55 -21.8 161.9 83.97 161.9 83.57 161.0...
Page 635
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (70HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 131.0 66.36 131.0 66.69 130.1 67.36 130.1 68.36 130.1 65.15 127.7 62.13 -21.8 152.8 67.36 152.8 67.70 151.9...
Page 636
Multi V 5 Outdoor Units 7. Capacity Tables ARUM720LTE5 Heating Capacity (72HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 136.2 77.2 136.2 77.79 135.3 78.33 135.3 79.14 135.3 79.95 132.9 81.21 -21.8 168.0 78.39 168.0...
Page 637
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (72HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 134.1 86.94 134.1 86.64 133.2 80.82 133.2 85.86 133.2 85.53 130.5 85.38 -21.8 165.0 86.46 165.0 86.16 164.1...
Page 638
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (72HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 132.9 68.31 132.9 68.73 132.0 69.57 132.0 70.83 132.0 67.50 129.6 64.38 -21.8 156.3 69.57 156.3 69.99 155.4...
Page 639
Multi V 5 Outdoor Units 7. Capacity Tables ARUM740LTE5 Heating Capacity (74HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 142.0 75.9 142.0 76.70 141.2 77.37 141.2 78.37 141.2 79.36 138.9 80.90 -21.8 173.7 77.46...
Page 640
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (74HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 139.8 85.97 139.8 85.85 138.9 80.68 138.9 85.54 138.9 85.41 136.5 85.35 -21.8 170.6 85.78 170.6 85.66 169.7...
Page 641
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (74HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 138.6 67.73 138.6 68.24 137.7 69.27 137.7 70.81 137.7 67.44 135.4 64.27 -21.8 161.6 69.27 161.6 69.78 160.6...
Page 642
Multi V 5 Outdoor Units 7. Capacity Tables ARUM760LTE5 Heating Capacity (76HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 143.4 77.7 143.4 78.58 142.5 79.37 142.5 80.56 142.5 81.72 140.8 83.55 -21.8 175.6 79.48 175.6...
Page 643
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (76HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 141.1 88.19 141.1 88.22 140.2 83.42 140.2 88.30 140.2 88.34 138.3 88.36 -21.8 172.5 88.23 172.5 88.27 171.6...
Page 644
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (76HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 139.9 69.60 139.9 70.20 139.0 71.42 139.0 73.24 139.0 69.79 137.2 66.56 -21.8 164.8 71.42 165.1 72.02 164.0...
Page 645
Multi V 5 Outdoor Units 7. Capacity Tables ARUM780LTE5 Heating Capacity (78HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 152.0 80.5 152.0 81.23 151.0 81.88 151.0 82.85 151.0 83.82 148.6 85.32 -21.8 184.6 81.97 184.6...
Page 646
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (78HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 149.5 89.83 149.5 89.77 148.6 84.64 148.6 89.60 148.6 89.54 146.0 89.51 -21.8 181.4 89.73 181.4 89.67 180.4...
Page 647
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (78HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 148.2 71.20 148.2 71.69 147.3 72.70 147.3 74.20 147.3 70.64 143.9 67.30 -21.8 170.5 72.70 170.5 73.19 169.4...
Page 648
Multi V 5 Outdoor Units 7. Capacity Tables ARUM800LTE5 Heating Capacity (80HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 154.2 84.1 154.2 84.79 153.2 85.40 153.2 86.31 153.2 87.22 150.8 88.62 -21.8 188.4 85.48 188.4...
Page 649
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (80HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 151.7 94.65 151.7 94.36 150.8 88.16 150.8 93.61 150.8 93.30 148.1 93.15 -21.8 185.1 94.20 185.1 93.90 184.1...
Page 650
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (80HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 150.4 74.33 150.4 74.80 149.5 75.74 149.5 77.14 149.5 73.47 146.9 70.02 -21.8 174.9 75.74 174.9 76.20 173.8...
Page 651
Multi V 5 Outdoor Units 7. Capacity Tables ARUM820LTE5 Heating Capacity (82HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 158.1 87.1 158.1 87.76 157.2 88.38 157.2 89.31 157.2 90.23 154.6 91.66 -21.8 193.2 88.46 193.2...
Page 652
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (82HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 155.6 97.92 155.6 97.60 154.6 91.16 154.6 96.81 154.6 96.47 151.9 96.31 -21.8 189.8 97.44 189.8 97.12 188.8...
Page 653
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (82HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 154.3 76.89 154.3 77.36 153.3 78.32 153.3 79.75 153.3 75.96 150.7 72.39 -21.8 179.3 78.32 179.3 78.80 178.2...
Page 654
Multi V 5 Outdoor Units 7. Capacity Tables ARUM840LTE5 Heating Capacity (84HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 160.1 88.6 160.1 89.43 159.1 90.16 159.1 91.25 159.1 92.34 156.6 94.03 -21.8 196.4 90.25 196.4...
Page 655
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (84HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 157.6 100.3 157.6 100.1 156.6 93.75 156.6 99.49 156.6 99.25 153.8 99.14 -21.8 192.9 99.93 192.9 99.71 191.9...
Page 656
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (84HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 156.2 78.84 156.2 79.40 155.2 80.53 155.2 82.22 155.2 78.31 152.6 74.64 -21.8 182.8 80.53 182.8 81.09 181.7...
Page 657
Multi V 5 Outdoor Units 7. Capacity Tables ARUM860LTE5 Heating Capacity (86HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 163.5 90.2 163.5 90.99 162.5 91.65 162.5 92.64 162.5 93.62 159.5 95.15 -21.8 201.3 91.73 201.3...
Page 658
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (86HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 161.0 101.6 161.0 101.3 159.9 94.69 159.9 100.5 159.9 100.2 156.7 100.1 -21.8 197.7 101.1 197.7 100.8 196.6...
Page 659
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (86HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 159.6 79.97 159.6 80.48 158.5 81.50 158.5 83.03 158.5 79.13 155.6 75.47 -21.8 187.2 81.50 187.2 82.01 186.1...
Page 660
Multi V 5 Outdoor Units 7. Capacity Tables ARUM880LTE5 Heating Capacity (88HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 164.9 92.0 164.9 92.87 163.8 93.65 163.8 94.83 163.8 95.98 161.4 97.80 -21.8 203.2 93.75 203.2...
Page 661
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (88HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 162.3 103.8 162.3 103.7 161.2 97.43 161.2 103.3 161.2 103.1 158.5 103.1 -21.8 199.6 103.6 199.6 103.4 198.5...
Page 662
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (88HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 160.9 81.84 160.9 82.44 159.8 83.65 159.8 85.46 159.8 81.48 157.4 77.76 -21.8 190.4 83.65 190.7 84.25 189.5...
Page 663
Multi V 5 Outdoor Units 7. Capacity Tables ARUM900LTE5 Heating Capacity (90HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 173.5 94.8 173.5 95.52 172.3 96.16 172.3 97.12 172.3 98.08 169.2 99.57 -21.8 212.2 96.24 212.2...
Page 664
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (90HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 170.7 105.5 170.7 105.2 169.6 98.65 169.6 104.6 169.6 104.3 166.2 104.2 -21.8 208.5 105.1 208.5 104.8 207.3...
Page 665
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (90HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 169.2 83.44 169.2 83.93 168.1 84.93 168.1 86.42 168.1 82.33 164.1 78.50 -21.8 196.1 84.93 196.1 85.42 194.9...
Page 666
Multi V 5 Outdoor Units 7. Capacity Tables ARUM920LTE5 Heating Capacity (92HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 175.7 98.4 175.7 99.08 174.5 99.68 174.5 100.6 174.5 101.5 171.4 102.9 -21.8 216.0 99.75 216.0...
Page 667
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (92HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 172.9 110.3 172.9 109.8 171.8 102.2 171.8 108.6 171.8 108.1 168.3 107.9 -21.8 212.2 109.6 212.2 109.1 211.0...
Page 668
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (92HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 171.4 86.57 171.4 87.04 170.3 87.97 170.3 89.36 170.3 85.16 167.1 81.22 -21.8 200.5 87.97 200.5 88.43 199.3...
Page 669
Multi V 5 Outdoor Units 7. Capacity Tables ARUM940LTE5 Heating Capacity (94HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 179.6 101.3 179.6 102.1 178.5 102.7 178.5 103.6 178.5 104.5 175.2 105.9 -21.8 220.8 102.7 220.8...
Page 670
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (94HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 176.8 113.6 176.8 113.1 175.6 105.2 175.6 111.8 175.6 111.3 172.1 111.0 -21.8 216.9 112.8 216.9 112.3 215.7...
Page 671
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (94HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 175.3 89.13 175.3 89.60 174.1 90.55 174.1 91.97 174.1 87.65 170.9 83.59 -21.8 204.9 90.55 204.9 91.03 203.7...
Page 672
Multi V 5 Outdoor Units 7. Capacity Tables ARUM960LTE5 Heating Capacity (96HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 181.6 102.9 181.6 103.7 180.4 104.4 180.4 105.5 180.4 106.6 177.2 108.3 -21.8 224.0 104.5 224.0...
Page 673
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (96HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 178.8 115.9 178.8 115.5 177.6 107.8 177.6 114.5 177.6 114.0 174.0 113.8 -21.8 220.0 115.3 220.0 114.9 218.8...
Page 674
Multi V 5 Outdoor Units 7. Capacity Tables Heating Capacity (96HP) Indoor air temp. °C DB Outdoor air temp. Combination °C DB °C WB -24.8 177.2 91.08 177.2 91.64 176.0 92.76 176.0 94.44 176.0 90.00 172.8 85.84 -21.8 208.4 92.76 208.4 93.32 207.2...
Page 679
Multi V 5 Outdoor Units 8. Capacity Correction Factor Note 1. These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load under standard conditions.(Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures.) 2.
Page 680
Multi V 5 Outdoor Units 8. Capacity Correction Factor Equivalent length Equivalent length * (Cooling) Overall equivalent length =80 m x 0.5 + 40 m = 20HP 80 m * (Heating) Overall equivalent length =80 m x 0.2 + 40 m = Indoor Unit 56 m Gas pipe...
Page 681
Multi V 5 Outdoor Units 8. Capacity Correction Factor 8.5 Defrosting Correction Factor for Heating Operation The capacity table does not consider reduction in capacity when frost has accumulated or during defrosting. The capacity values considered these factors, in other words the integrated heating capacity values, can be obtained as follows: [ Formula ] •...
Page 684
• Sound level can be increased in static pressure mode or used air guide. Unit:dB(A) Model Cooling Heating ARUM080LTE5 58.0 59.0 ARUM100LTE5 58.0 59.0 ARUM120LTE5 59.0 60.0 ARUM140LTE5 60.0...
Page 691
Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment in installed. • Reference acoustic intensity 0dB = 10E-6μW/m Model Cooling Heating ARUM080LTE5 77.0 78.0 ARUM100LTE5 78.0 79.0 ARUM120LTE5 79.0...
Page 698
Multi V 5 Outdoor Units 11. Accessories Optional Accessories Name Model ARBLN01621 / ARBLB01621 ARBLN03321 / ARBLB03321 Y branch pipe ARBLN07121 / ARBLB07121 ARBLN14521 / ARBLB14521 ARBLN23220 / ARBLB23220 ARBL054 ARBL057 ARBL104 Header ARBL107 ARBL1010 ARBL2010 ARCNB21 / ARCNN21 Connection pipe of Outdoor Units ARCNB31 / ARCNN31 ARCNB41 / ARCNN41...
Page 699
Heat Recovery HR Unit Multi V 5 1.Nomenclature 2.Specifications 3.Dimensions 4.Prats Function 5.Piping Diagrams 6.Wiring Diagrams 7.Sound Levels...
Page 700
Multi V 5 Heat Recovery HR Unit 1. Nomenclature Model Name PRHR Signification HR Unit connecting to Multi V Heat Recovery System Outdoor Unit using R410A PRHR : Global line-up The No. of connected branches 02 : For 2 branches 03 : For 3 branches 04 : For 4 branches 06 : For 6 branches...
Page 701
Multi V 5 Heat Recovery HR Unit 2. Specifications Model PRHR023 PRHR033 PRHR043 Max. Connectable No. of Indoor Units Max. Connectable No. of Indoor Units of a branch Cooling(W) 39.8 39.8 39.8 Nominal Input Heating(W) 37.2 37.2 37.2 16.0 17.8 19.3 Net.
Page 702
Multi V 5 Heat Recovery HR Unit 2. Specifications Model PRHR063 PRHR083 Max. Connectable No. of Indoor Units Max. Connectable No. of Indoor Units of a branch Cooling(W) 75.9 75.9 Nominal Input Heating(W) 72.1 72.1 27.2 30.7 Net. Weight 60.0 67.7 1,113 x 218 x 657 Dimensions...
Page 703
Multi V 5 Heat Recovery HR Unit 3. Dimensions PRHR023 / PRHR033 / PRHR043...
Page 704
Multi V 5 Heat Recovery HR Unit 3. Dimensions PRHR063 / PRHR083...
Page 705
Multi V 5 Heat Recovery HR Unit 4. Parts Function Parts Name Symbol Major Function Low pressure gas pipe LPGV Pipe for Low pressure gas High pressure gas pipe HPGV Pipe for High pressure gas Liquid pipe 1 Liquid pipe connected with outdoor unit Liquid bypass valve Prevent Liquid charging Solenoid Assembly 1, 2...
Page 706
Multi V 5 Heat Recovery HR Unit 5. Piping Diagrams Low pressure gas pipe Liquid pipe High pressure gas pipe Solenoid Sensor • A : To be switched operation between cooling and heating by two valves • B : To be used decreasing noise according to sub-cooling of inlet of indoor unit and outlet of indoor unit (Simultaneous operation) •...
Page 707
Multi V 5 Heat Recovery HR Unit 6. Wiring Diagrams PRHR023, PRHR033, PRHR043 CONNECTOR NUMBER FUNCTION CN_R1_MP EEV 01 (Bypass for Room1) CN_R2_MP EEV 02 (Bypass for Room2) CN_R3_MP EEV 03 (Bypass for Room3) CN_R4_MP EEV 04 (Bypass for Room4) CN_R1_HL EEV 01 Low/High (For Room1) CN_R2_HL...
Page 708
Multi V 5 Heat Recovery HR Unit 6. Wiring Diagrams PRHR063, PRHR083 CONNECTOR NUMBER FUNCTION CN_R1_MP EEV 01 (Bypass for Room1) CN_R2_MP EEV 02 (Bypass for Room2) CN_R3_MP EEV 03 (Bypass for Room3) CN_R4_MP EEV 04 (Bypass for Room4) CN_R1_HL EEV 01 Low/High (For Room1) CN_R2_HL EEV 02 Low/High (For Room2)
Page 709
Multi V 5 Heat Recovery HR Unit 6. Wiring Diagrams CONNECTOR NUMBER FUNCTION Setting, EEV Number(When Manual Address) SW01E Setting, Time of Zoning Address(When Auto Address) SW02E(1) Selecting, Auto Address( ) or Manual Address( SW02E(2~4) Setting, Total Number of Indoor connected SW02E(5) Setting, Slave PCB SW02E(6)
Page 710
Multi V 5 Heat Recovery HR Unit 7. Sound Levels 7.1 Sound pressure level Overall Note • Sound measured at 1.5m away from the center of the unit. • Operating condition| - Power source : 220-240V 50Hz / 220V 60Hz - Cooling : Indoor temperature (27°C DB, 19°C WB), Outdoor temperature (35°C DB, 24°C WB) - Heating : Indoor temperature (20°C DB, 15°C WB),...
Page 711
Multi V 5 Heat Recovery HR Unit 7. Sound Levels Changeover : Heating Cooling NC-70 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 Approximate NC-20 Hearing Threshold NC-15 1000 2000 4000 8000 Octave Band Center Frequency (Hz)
Page 712
Installation of Outdoor Units Multi V 5 1.Alternative Refrigerant R410A 2.Select the Best Location 3.Installation Space 4.Lifting Method 5.Installation 6.Refrigerant piping Installation 7.Refrigerant piping system 8.Electrical Wiring 9.Setting Function...
Page 713
Multi V 5 Installation of Outdoor Units 1. Alternative Refrigerant R410A • The refrigerant R410A has the property of higher operating pressure in comparison with R22. Therefore, all materials have the characteristics of higher resisting pressure than R22 ones and this characteristic should also be considered during the installation.
Page 714
Multi V 5 Installation of Outdoor Units 2. Select the Best Location Select space for installing outdoor unit, which will meet the following conditions: • No direct thermal radiation from other heat sources • No possibility of annoying neighbors due to noise of unit •...
Page 715
Multi V 5 Installation of Outdoor Units 3. Installation Space 3.1 Individual Installation ■ Select installation location of the HR unit suitable for following conditions • Avoid a place where rain may enter since the HR unit is for indoor. •...
Page 716
Multi V 5 Installation of Outdoor Units 3. Installation Space PRHR063 / PRHR083 [Unit : mm(inch)] 100 (3-15/16) more 809(31-27/32) (Serviceing space) 300(11-13/16) more 300(11-13/16) more (Servicing space) (Servicing space) 100 (3-15/16) more Inspection door (Serviceing space) (servicing space) 800(31-1/2) 300(11-13/16) more 450(17-23/32) more (Servicing space)
Page 717
Multi V 5 Installation of Outdoor Units 3. Installation Space ■ Required space around the unit During the installation of the unit, consider service, inlet, and outlet and acquire the minimum space as shown in the figures below. Side space should be more than 49mm(1-15/16inch) for operating of Auto Dust Removal mode.
Page 718
Multi V 5 Installation of Outdoor Units 3. Installation Space Case 1 Case 2 Category Installation Space (10mm≤Side Space≤49mm) (Side Space≥49mm) A ≥ 10(13/32) No limit for the height of wall B ≥ 300(11-13/16) Front Only 2 sides are walls A ≥...
Page 719
Multi V 5 Installation of Outdoor Units 4. Lifting Method • When carrying the suspended, unit pass the ropes under the unit and use the two suspension points each at the front and rear. • Always lift the unit with ropes attached at four points so that impact is not applied to the unit. •...
Page 720
Multi V 5 Installation of Outdoor Units 5. Installation • Install at places where it can endure the weight and vibration/noise of the outdoor unit. • The outdoor unit support block at the bottom shall have width of at least 100mm(3-15/16inch) under the units legs before being fixed.
Page 721
Multi V 5 Installation of Outdoor Units 5. Installation 5.2 Foundation for Installation • Fix the unit tightly with bolts as shown below so that unit will not fall down due to earthquake or gust. • Use the H-beam support as a base support •...
Page 722
Multi V 5 Installation of Outdoor Units 6. Refrigerant piping Installation 6.1 Precautions on Pipe connection / Valve operation Pipe connection is done by connecting from the end of the pipe to [Heat Pump] the branching pipes, and the refrigerant pipe coming out of the Service Port outdoor unit is divided at the end to connect to each indoor unit.
Page 723
Multi V 5 Installation of Outdoor Units 6. Refrigerant piping Installation 6.2 Connection of Outdoor units When installing outdoor unit series, refer below picture. (Master) (Slave1) (Slave2) (Slave3) A≥B≥C≥D ① Indoor unit side connection pipe ② Outdoor unit to outdoor unit connection pipe (1st branch) ③...
Page 724
Multi V 5 Installation of Outdoor Units 6. Refrigerant piping Installation ■ Heat Pump System Liquid pipe Gas pipe Outdoor unit Model [unit:mm(inch)] [unit:mm(inch)] 2 unit ⓒ ARCNN21 3 unit ⓑ ARCNN31 4 unit ⓐ ARCNN41 For more information including installation method of connection pipe, refer accessory installation manual.
Page 725
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.1 Pipe Connection Method between outdoor unit/indoor unit 7.1.1 Heat Recovery System : 4 Outdoor Units Example : 12 Indoor Units connected ⓐ Outdoor Unit ⓑ Y branch ⓓ Indoor Units E : Connection branch pipe between Outdoor units : ARCNB41 F : Connection branch pipe between Outdoor units : ARCNB31 G: Connection branch pipe between Outdoor units : ARCNB21...
Page 726
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Total pipe length = A+B+C1+C2+C3+D+a+b+c+d+e+f+g+i+j+k+l+m+n ≤ 1,000 Total pipe length 1,000m [3,281ft] (A+B+C1+C2+C3+D+a+b+c+d+e+f+g+i+j+k+l+m+n) Longest pipe length (A+B+C3+D+k) 150m [492ft] : between Outdoor Unit and Indoor Unit (200m [656ft]**) Max.pipe length Longest pipe Equivalent length* 175m [574ft]...
Page 727
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Refrigerant pipe diameter from branch to branch (B,C) Gas pipe [mm(inch)] Downward indoorunit total Liquid pipe[mm(inch)] capacity[kW(Btu/h)] Low pressure High pressure Ø6.35(1/4) Ø12.7(1/2) Ø9.52(3/8) ≤ 5.6(19,100) < 16.0 (54,600) Ø9.52(3/8) Ø15.88(5/8) Ø12.7(1/2)
Page 728
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Y branch, Header and HR unit connection pattern Pattern 1 Pattern 2 • Impossible installation : HR unit Head branch • Impossible installation : Head branch pipe HR unit pipe Y and Head branch pipe.
Page 729
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system Pattern 7 * : Serial connection of HR units : Capacity sum of indoor units ≤ 230 kBtu/h Pattern 8 * : Maximum indoor units per a branch are 8 indoor units t i n Head Branch pipe...
Page 730
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.1.2 Heat Pump System ■ Single Outdoor Unit Connection Y branch method ⓐ Outdoor Unit ⓑ 1st branch (Y branch) Indoor Unit ⓓ Indoor Units L 150m [492ft] (200m [656ft] : Conditional application)* l 40m [131ft] (90m [295ft] : Conditional application)* h 40m [131ft] Combination of Y branch / header method...
Page 731
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Series Outdoor Unit Connection Y branch method ODU Capacity Master ≥ Slave 1 ≥Slave 2 ≥Slave 3 ⓐ Outdoor Unit Indoor ⓑ 1st branch (Y branch) Unit 10m [32.8ft] or less ⓓ...
Page 732
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Limits of pipe length and difference in height Combination of Y Connection method Y branch only Header only branch/header A+B+b ≤ 150m [492ft] ) Longest pipe length (L) (200m [656ft]**) A+B+C+D+e ≤...
Page 733
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Refrigerant pipe diameter from branch to branch (B,C,D) Downward Indoor Unit total capacity Liquid pipe Gas pipe [kW(Btu/h)] [mm(inch)] [mm(inch)] Ø6.35(1/4) Ø12.7(1/2) ≤ 5.6(19,100) < 16.0(54,600) Ø9.52(3/8) Ø15.88(5/8) <...
Page 734
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Outdoor unit Connection Slave1 Master Slave2 Slave3 Indoor Unit 1st branch Refrigerant pipe diameter from outdoor unit to first branch l 40m h 40m * Maximum number of connectable units could be different in accordance with model line up of target region. A : Refrigerant pipe diameter from outdoor unit to first branch E : Refrigerant pipe diameter for outdoor unit capacity (Slave 1+ Slave 2+ Slave 3) F : Refrigerant pipe diameter for outdoor unit capacity (Slave 2+ Slave 3)
Page 735
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.2 Indoor Unit Connection Indoor Unit connecting pipe from branch (a, b, c, d, e, f) Indoor Unit capacity [kW(Btu/h)] Liquid pipe [mm(inch)] Gas pipe [mm(inch)] Ø6.35(1/4) Ø12.7(1/2) ≤...
Page 736
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.3 Pipe Connection Method/Precautions for Series connections between Outdoor units • Separate Y branch joints are needed for series connections between outdoor units. • Please refer to the below connection examples to install pipe connections between outdoor units. 7.3.1 Pipe connection between outdoor units (General Case) 7.3.2 Pipes between outdoor units are 2m(6.6ft) or less 7.3.3 Pipes between outdoor units are 2m(6.6ft) or longer...
Page 737
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.3.4 Examples of Wrong Pipe Connections • The pipes between the outdoor units must maintain horizontal levelness or give an inclination to prevent a back flow toward the slave outdoor unit. Otherwise, the unit may not operate properly. (Example 1) Toward indoor unit Toward indoor unit...
Page 738
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system (Example 2) Oil Trap 2m(6.6ft) ≤ Toward indoor unit ≤ 2m(6.6ft) • Install Oil trap if the ODU is at lower level than main piping. • When connecting the pipes between the outdoor units, the accumulation of oil in the slave outdoor unit should be avoided.
Page 739
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.4 The amount of Refrigerant The calculation of the additional charge should take into account the length of pipe and CF(correctionFactor) value of indoor unit. Additional charge(kg) Total liquid pipe : Ø25.4mm (1inch) ×...
Page 740
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.5 Selection of Y Branch, Header and Reducer 7.5.1 Y Branch ■ Heat Recovery System Low Pressure Gas pipe High Pressure Gas pipe Liquid pipe Models [unit:mm] [unit:mm] [unit:mm] I.D12.7 I.D12.7 I.D6.35...
Page 741
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system ■ Heat Pump System Gas pipe Liquid pipe Models [unit:mm] [unit:mm] I.D12.7 I.D12.7 I.D6.35 I.D.6.35 I.D9.52 I.D15.88 I.D15.88 I.D9.52 I.D15.88 I.D.6.35 ARBLN01621 I.D12.7 I.D.9.52 O.D9.52 O.D15.88 I.D12.7 I.D19.05 I.D22.2 I.D19.05 I.D15.88 I.D19.05...
Page 742
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.5.2 Header Gas pipe Liquid pipe Models [unit:mm] [unit:mm] ID12.7 ID6.35 ID6.35 ID12.7 4 branch ID9.52 ID15.88 ARBL054 ID9.52 ID15.88 ID15.88 ID12.7 ID9.52 ID19.05 ID12.7 ID6.35 7 branch ID12.7 ARBL057 ID9.52 ID15.88...
Page 743
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.5.3 Reducer Reducers for indoor unit and HR unit Gas pipe Liquid pipe [unit:mm] Models [unit:mm] High pressure Low pressure Indoor unit reducer OD9.52(3/8) Ø6.35(1/4) OD15.88(5/8) Ø 12.7(1/2) OD22.2(7/8) Ø19.05(3/4) Ø15.88(5/8) PRHR023 OD19.05(3/4) Ø15.88(5/8)
Page 744
Multi V 5 Installation of Outdoor Units 7. Refrigerant piping system 7.6 Distribution Method 7.6.1 Horizontal Distribution Slave Master 3rd main pipe distribution Slave Master Slave Master Main pipe Distribution Main pipe Distribution 7.6.2 Vertical Distribution Ensure that the branch pipes are attached vertically. Slave Master Slave...
Page 745
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 8.1 Electrical Wiring 8.1.1 Caution 1. Follow ordinance of your governmental organization for technical standard related to electrical equipment, wiring regulations and guidance of each electric power company. CAUTION Be sure to have authorized electrical engineers do the electric work using special circuits in accordance with regulations and this installation manual.
Page 746
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring ■ Precautions when laying power wiring Use round pressure terminals for connections to the power terminal Power wire block. Round pressure terminal When none are available, follow the instructions below. •...
Page 747
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 8.1.2 Control box and connecting positioning of wiring • Remove all of the screws at front panel and remove the panel by pulling it forward. • Connect communication line between main and sub outdoor unit through the terminal block.
Page 748
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 8.1.3 Communication and Power Lines 1. Communication cable • Types : shielded cables • Use wires of size : over 1.0 ~ 1.5 mm (1.55 × 10 ~ 2.32 × 10 •...
Page 749
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 8.2 DIP Switch Setting 8.2.1 Checking according to dip switch setting You can check the setting values of the Master outdoor unit from the 7 segment LED. The dip switch setting should be changed when the power is OFF.
Page 750
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring ■ Master / Slave Dip Switch Setting Master/Slave Unit Slave Master Slave1 Slave2 Slave3 Heat Pump System (Factory setting) Dip switch setting Heat Recovery System (Installer setting) Important How to setting Heat Recovery system 1.
Page 751
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 8.3 HR Unit PCB (For Heat Recovery System) Switch for setup of HR Unit Branch No. Main PCB (2EA, same P/No) Branch #1~4 Branch #5~8 Bypass Bypass (from left) SC EEV 7-SEG (from left) 7-SEG...
Page 752
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring ■ Main function of SW02E ON S/W Selection No.1 Method for pipe detection of an HR unit (Auto/Manual) No.2 No.3 No. of connected branches No.4 No.5 Master/Slave (Main PCB) Setting No.6 EEPROM factory initialization (4,5,6) No.7...
Page 753
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 3. Setting the zoning control SW02E setting SW01E setting Master Normal control SW01E Turn the dip switch of the zoning branch on. EX) Branch 1,2 are zoning control. Master Master Zoning control SW01E 4.
Page 754
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring ■ SW01D (Rotary S/W for addressing HR unit) Use the Valve Group Control when 2 branches are connected with only 1 indoor unit which has higher capacity than 61 kBtu/h. Valve Group SW01D Setting Valve Group...
Page 755
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring ■ SW01C (Rotary S/W for addressing HR unit) Must be set to '0' when installing only one HR unit. When installing multiple HR units, address the HR units with sequentially increasing numbers starting from '0'. Maximum 16 HR Units can be installed.
Page 756
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 1. Normal setting (Non-Zoning setting) ex) Manual pipe detection of Valve #1, 6. Master Master Master SW01E SW02B SW01B SW01E SW #1 On : Select Valve #1 Input the central control SW #1 Off : Finish Valve #1 address of Indoor unit Slave...
Page 757
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring 8.4 Automatic Addressing ■ The address of indoor units would be set by auto addressing 1. Wait for 3 minutes after supplying power. (Master and Slave outdoor units, indoor units) 2.
Page 758
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring The Procedure of Automatic Addressing Power On Waiting 3 minutes Press RED Button for 5 sec. (SW01C) Automatic addressing process start 7-segment LED = 88 Don’t press RED Button (SW01C) •...
Page 759
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring ■ Automatic pipe detection(For Heat Recovery System) 1. Turn No.1 dip switch of SW02E of HR unit PCB off. 2. Confirm that the setting of No.2, 3, 4 of SW02E corresponds with the type of the valve connection. 3.
Page 760
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring Flow chart of auto pipe detection process Confirm indoor unit’s address setting Outdoor unit is operated for 5~60 minues. Turn No.1 dip switch of SW02E of HR unit PCB off. Does the setting status Confirm that the setting of No.2, 3, 4 dip...
Page 761
Multi V 5 Installation of Outdoor Units 8. Electrical Wiring ■ Manual pipe detection 1. Enter the central control address into each indoor unit using its wired remote controller. 2. Turn No.1 dip switch of SW02E of HR unit PCB on. 3.
Page 762
Overall defrost Set for only using Overall Defrost (not applying Partial Defrost) ODU address Address for monitoring cycle view with LG control solutions Snow removal & rapid defrost Function for snow removal and rapid defrost function IDU capacity adjusting...
Page 763
Multi V 5 Installation of Outdoor Units 9. Setting the function 9.2 Dip Switch Setting Select the mode/function/option/value using ‘►’, ‘◀’ Button and confirm that using the ‘●’ button after dip switch No.5 is turned on. DIP-SW01 7-Segment SW04C (X : cancel) SW03C ( : forward) SW02C (...
Page 764
Multi V 5 Installation of Outdoor Units 9. Setting the function 9.3 Night Low Noise Function This function makes the ODU fan operate at low RPM to reduce the fan noise of ODU at night which has low load. Night low noise function setting method Master unit PCB DIP switch on : No.5 Select the mode using ‘...
Page 765
Multi V 5 Installation of Outdoor Units 9. Setting the function 9.4 High Static Pressure Compensation Function This function secures the air flow rate of ODU, in case static pressure has been applied like using duct at fandischarge of ODU. Master unit PCB DIP switch on : No.5 Select the mode using Button : “Func”...
Page 766
Special Guide Multi V 5 1.Cautions for Refrigerant Leaks 2.Guide for installing at seaside...
Page 767
Multi V 5 Special Guide 1. Caution For Refrigerant Leaks The installer and system specialist shall secure safety against leakage according to local regulations or standards. The following standards may be applicable if local regulations are not available. 1.1 Introduction Though the R410A refrigerant is harmless and incombustible itself , the room to equip the air conditioner should be large to such an extent that the refrigerant gas will not exceed the limiting concentration even if the refrigerant gas leaks in the room.
Page 768
Multi V 5 Special Guide 1. Caution For Refrigerant Leaks 1.2.2 Calculate refrigerant concentration level Calculate the volume of the room where indoor unit is installed as single room or the smallest room. 1. Without partition Outdoor unit Indoor unit 2.
Page 769
Multi V 5 Special Guide 1. Caution For Refrigerant Leaks In case the concentration exceeds the limit When the concentration exceeds the limit, change original plan or take one of the counter measure shown below: • Counter measure 1 Provide opening for ventilation.
Page 770
Multi V 5 Special Guide 2. Guide for installing at seaside CAUTION 1. Air conditioners must not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced. 2. Avoid installing the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the product.
Page 771
Control System Multi V 5 1.Solution Overview 2.Control System List 3.Function List 4.Accessory Compatibility List 5.Centralized Controller Compatibility List...
Page 772
Multi V 5 Control System 1. Solution Overview • 1) It is available 5 series controllers (ACP5, AC Smart5) only. • If you need more detail, please refer to the Control PDB or the manual of product. (http://partner.lge.com/global : Home> Doc.Library> Product > Control(BECON))
Page 773
Multi V 5 Control System 2. Control System List Dimensions Controller Compatible Category Model name Feature name Product (W x H x D, mm) • 5 inch color Display PREMTA000(A/B) • Touch Screen Premium All IDU • Group control (Max 16 indoor unit) Wired 137 x 121 x 16.5 •...
Page 774
Multi V 5 Control System 2. Control System List Outline of system 1. Installation Method ① ② ③ ※ ① : AWG#24 / ②, ③ : AWG#22 The total cable length must not exceed 50m. (It can cause communication error.) 2.
Page 775
Multi V 5 Control System 2. Control System List Dimensions Controller Compatible Category Model name Feature name Product (W x H x D, mm) • PC Access Controller All IDU PACM5A000 • DC 12 V Adaptor • Max 8,192 indoor unit control ERV DX AC Manager 5 270 x 155 x 65...
Page 776
Multi V 5 Control System 2. Control System List Outline of system When using a HUB, use Direct UTP Cable. AC Manager 5 Max.length of total transmission wiring for centralized control : 1km Ethernet (Direct UTP Cable) Web access Remote controller Remote controller •...
Page 777
Multi V 5 Control System 2. Control System List Dimensions Controller Compatible Category Model name Feature name Product (W x H x D, mm) PACS5A000 • 10.2 inch color Display • Touch Screen • DC 12 V Adaptor AC Smart 5 •...
Page 778
Multi V 5 Control System 2. Control System List Outline of system Max.length of total transmission wiring for centralized control : 1km Up to 128 units by individual control • Communication cable – Types : shielding wire – Use wires of size : over 0.75 ~ 1.5 mm –...
Page 779
Multi V 5 Control System 2. Control System List Dimensions Controller Category Model name Objective / Use Feature name (W x H x D, mm) PDRYCB000 • 1SET / 1 IDU PDRYCB100 • 1 Contact point For Connect • Input power AC 220V~240 V indoor unit to 120 x 120 x 36.5 –...
Page 780
CN-CC 24 V~ To Apply Power Source through PCB To Apply Power Source Directly to External Source CN_Ther/Oper CN_MODE Thermostat Thermostat LG does not LG does not CN_WIND CHANGEOVER_SW supply this section supply this section Connect separate (Field supply) (Field supply)
Page 781
Multi V 5 Control System 2. Control System List Dimensions Controller Category Model name Objective / Use Feature name (W x H x D, mm) PRDSBM • Push Button Type Cool/Heat To Select 74 x 120 x103 Selector Operation Mode •...
Page 782
Multi V 5 Control System 2. Control System List Outline of system Main PCB Transformer IO Module Variable Water Flow Valve Terminal Block Variable Water Field Flow Valve control KIT Supply (Accessory) Damper Damper Damper Actuator Actuator Actuator IO Module AC 220V Main PCB Terminal...
Page 783
Multi V 5 Control System 2. Control System List Dimensions Controller Category Model name Objective / Use Feature name (W x H x D, mm) PAHCMR000 • UI 4EA (AI/DI) Return Air • DO 3EA (Relay, A type) AHU Comm. Kit Temperature 300 X 300 X 155 •...
Page 784
) can be changed in MULTI V and Single outdoor setting. LG wired remote controller and LG Central Controller can be optionally applied, but only monitoring function is possible. • If you need more detail, please refer to the Control PDB or the manual of product.
Page 785
The DDC controls return air temperature (Tr) or room air temperature (TRoom) by transferring Modbus signal to the AHU Communication Kit for Return air control. To control room air, the LG wired controller can be purchased optionally. A fixed target evaporator or condensing temperature (T ) can be changed in MULTI V and Single outdoor setting.
Page 786
Multi V 5 Control System 2. Control System List Outline of system • DDC Control by Contact Signal : Variable T (0~10 V) LG Central (Field Supply) Controller AI / DI / DO Room (Monitoring only) Room Signal Remote Controller...
Page 787
Multi V 5 Control System 2. Control System List Dimensions Controller Category Model name Objective / Use Feature name (W x H x D, mm) PRCTIL0 • Length of cable : 1m (3m extension cable is included) LGMV data Maintenance monitoring via •...
Page 788
Multi V 5 Control System 2. Control System List Outline of system 1. Outdoor connection Connect LGMV cable to Multi V PCB LGMV port 2. Indoor unit connection Connect LGMV cable to Multi V Indoor unit communication port • If you need more detail, please refer to the Control PDB or the manual of product. (http://partner.lge.com/global : Home>...
Page 789
Multi V 5 Control System 2. Control System List Dimensions Controller Category Model name Objective / Use Feature name (W x H x D, mm) PLGMVW100 • The effective distance for wireless communication is 10m Maintenance Mobile LGMV monitoring • The effective distance may be 48 x 78 x 14.5 Accessory LGMV...
Page 790
Multi V 5 Control System 2. Control System List Outline of system • If you need more detail, please refer to the Control PDB or the manual of product. (http://partner.lge.com/global : Home> Doc.Library> Product > Control(BECON))
Page 791
Multi V 5 Control System 3. Function List Individual Controller Premium Wired Simple Wired Simple Wired Wireless Standard Wired Remote Controller Name Remote Remote Remote Remote Controller Controller Controller Controller Controller Product Image PREMTA000 PREMTB100 PREMTB001 PQRCVCL0Q PQRCHCA0Q Model Name PREMTA000A PQWRHQ0FDB PREMTBB10...
Page 792
Multi V 5 Control System 3. Function List Central Controller Controller Name AC Ez AC Ez touch AC Smart IV AC Smart 5 Product Image Model Name PQCSZ250S0 PACEZA000 PACS4B000 PACS5A000 Maximum Number of Indoor Units Individual / Group Control (On &...
Page 793
Multi V 5 Control System 3. Function List Controller Name ACP IV AC Manager IV AC Manager 5 ACP 5 Product Image Model Name PACP4B000 PACP5A000 PACM4B000 PACM5A000 Maximum Number of Indoor 8,192 8,192 Units Individual / Group Control (On & Off, Mode, Set Point, Fan Speed) Individual Controller Lock (Temperature, Mode,...
Page 794
Multi V 5 Control System 4. Accessory Compatibility List Product Model name Compatibility Wireless Remote PQWRH(C)Q0FDB ○ Controller PQRCVCL0Q(W) Simple ○* Simple PQRCHCA0Q(W) for Hotel ○* PREMTB001 Standard II(White) ○ Wired Remote PREMTBB01 Standard II (Black) ○ Standard Controller PREMTB100 Standard III (White) ○...
Page 795
Multi V 5 Control System 4. Accessory Compatibility List E.O.L Model Product Model name Compatibility Wireless Remote PQWRH(C)DF0 Controller Wired PQRCVSL0 RS2 Wired (black) Remote Standard PQRCVSL0QW RS2 Wired (White) Controller PQDSA Simple Contact PQDSA(1) PQDSB(1) Dry contact PQDSBC PQDSBNGCM1 Communication type PQDSBCGCD0 Dry Contact for Thermostat...
Page 796
Multi V 5 Control System 5. Centralized Controller Compatibility List Compatibility between Controllers Slave (B) Master (A) ACP IV AC Smart IV AC Ez AC Ez Touch ACP BACnet AC Smart 5 Lonworks ACP 5 AC Ez AC Ez Touch AC Smart IV, AC Smart 5 ACP IV, ACP 5...