INSTALLATION INSTRUCTIONS
Prime all traps, test for leaks, and insulate in areas where
sweating of the traps and drain lines could potentially cause
water damage. Consult
requirements or precautions.
If a gravity drain cannot be used, install a condensate pump.
Install the pump as close to the indoor section as possible.
CAUTION
!
PRODUCT or PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in product or
property damage.
Use only full size P- traps in the condensate line (refer to
Figure 16). Shallow, running traps are inadequate and
DO NOT allow proper condensate drainage (refer to
Figure 17).
Figure 16
Recommended Condensate Trap
UNIT
Figure 17
Insufficient Condensate Trap
DO NOT USE SHALLOW RUNNING TRAPS!
12
local codes for additional
2" MIN (51mm)
2" MIN (51mm)
Specifications are subject to change without notice.
Fan Coils: FEM4X, FEM4P, REM4X, FXM4X
Figure 18
PRIMARY TRAP REQUIRED (USE FACTORY KIT OR
FIELD- SUPPLIED TRAP OF PROPER DEPTH.
STANDARD P- TRAPS ARE NOT SUFFICIENT. SEE
FIGURE OF RECOMMENDED CONDENSATE TRAP)

ACCESSORIES

A. HUMIDIFIER
Connect humidifier and humidistat to fan coil unit as shown in
Figure 19 and Figure 20.
Wiring Layout of Humidifier to Heat
Figure 19
THERMOSTAT
RED
R
GRY
G
BRN
C
WHT
W
2
WHT
BLU
E
VIO
L
O
Y
FAN HUMIDIFIER
115V
M
Condensate Drain
FILTER
ACCESS
PANEL
SECONDARY DRAIN WITH
APPROPRIATE TRAP REQUIRED
(USE FACTORY KIT OR
FIELD- SUPPLIED TRAP)
Pump
FAN COIL
HEAT PUMP
(CONTROL)
(CONTROL)
R
R
G
C
C
W
2
W
3
E
W
2
O
Y
RELAY
HUMIDISTAT
496 01 5503 01