Download Print this page
NDS ZeroWire G2 User Manual

NDS ZeroWire G2 User Manual

High-definition wireless video system
Hide thumbs Also See for ZeroWire G2:

Advertisement

Quick Links

ZeroWire® G2
High-Definition Wireless Video System
User manUal
[ E N g l I s H ]

Advertisement

loading

Summary of Contents for NDS ZeroWire G2

  • Page 1 ZeroWire® G2 High-Definition Wireless Video System User manUal [ E N g l I s H ]...
  • Page 3 © 2015 NDS Surgical Imaging, LLC. All rights reserved. Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. NDSsi provides this information as reference only.
  • Page 5 Tab 1 Warnings and Cautions ------------------------------------------------------------------------------ ii Recycling ------------------------------------------------------------------------------------------------- ii Declarations of Conformity ------------------------------------------------------------------------ iii Legal Statement -------------------------------------------------------------------------------------- iii Tab 2 About This Manual ------------------------------------------------------------------------------------ 1 Intended Use and Contraindications ------------------------------------------------------------ 1 Overview ------------------------------------------------------------------------------------------------- 1 Tab 3 Connector Panels ------------------------------------------------------------------------------------- 2 Installation ---------------------------------------------------------------------------------------------- 3 Power Options ----------------------------------------------------------------------------------------- 4 Wiring Diagrams -------------------------------------------------------------------------------------- 6...
  • Page 6 Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC. FCC Identification: UEZ-WT-P42-13, UEZ-WR-P42-11 Industry Canada: 9203A-90T2072, 9203A-90T2071 This product complies to the above standards only when used with an NDS supplied medical grade power supply. Power Cord: Use a hospital grade power cord with the correct plug for your power source.
  • Page 7 and 2007/47/EC    ...
  • Page 8 Tx and the Rx. The ZeroWire G2 transmitter and receiver pair allows wireless delivery of video signals from the DVI or 3G- SDI output of an endoscopic camera processor or other video source to the DVI input of a video display. It...
  • Page 9 ZeroWire G2 Transmitter ZeroWire G2 Receiver The USB port is used for installing updates to the Tx or Rx firmware. It is not a general purpose I/O port The BOND button allows the bonding of a transmitter to a receiver.
  • Page 10 Replace the right hand screws with the screws provided and tighten all screws. With the flat surface of a ZeroWire G2 Rx or Tx module facing the front of the display, align the slot on the bottom of the module with the top of the bracket and push the module down on the bracket until the module seats.
  • Page 11 ZeroWire G2 transmitters and receivers may be powered from the provided power supply (pictured below), or when used with an NDS display they may be powered from the display’s, NDS supplied, power supply via the supplied ‘Y’ adapter cable. ‘Y’ adapter cables, shown below, are available for Radiance 19”, 24”, 26”...
  • Page 12 When using the included power supply, select and install the plug adapter that matches the wall socket in your OR. GlobTek GTM91120-3024-T3A Ault MW172KB2400B02 Provided power supply or J3 of the ‘Y’ adapter connects here.
  • Page 13 Display Mounted Rx Wiring diagram “Y Cable DVI Cable Power Supply Connector We recommend that the bend radius of metallic cables be no less than 2.5 inches (63 mm) or 7 times the diameter of the cable whichever is greater. Sharper bends may damage the cable and / or degrade the video signal.
  • Page 14 Bonding the Transmitter (Tx) and Receiver (Rx) Before the ZeroWire G2 wireless system can be put into service , the Tx and Rx pair must be bonded. Connect an included power supply or a ‘Y’ Adapter cable to a Tx and an Rx unit. See pages 4 and 5 for ‘Y’...
  • Page 15 Performance: ZeroWire G2 Wireless HD Video System products are intended and optimized for use in a surgical operating room (OR). Use outside of an OR environment is not recommended. The following steps will help you to achieve optimal performance of the ZeroWire G2 system: 1.
  • Page 16 Due to the shape of the antenna’s signal field (image 1), both Tx and Rx units should be installed so they are vertical within + or - 10°, and horizontal within + or - 10°. Vertical Alignment: Vertical alignment should be within + or - 10°...
  • Page 17 Separation: ZeroWire G2 operates correctly with a Tx and Rx separation of up to 30 feet (10 m). However, in the case of most OR environments, best results are achieved with a Tx and Rx separation distance of up to 8 feet (2.4 m).
  • Page 18 Test results indicate that ZeroWire achieves a better signal-to-noise ratio when the Tx and Rx are oriented at certain angles relative to one another. Optimum link quality is achieved when the Tx and Rx are aligned at 0° relative to each other. Acceptable link quality is achieved when the Tx and Rx are aligned at angles between 0 to 45°, 90°...
  • Page 19 Tx and the OR rooms whose walls and/or ceiling are constructed with metal sheets, may reduce ZeroWire G2 performance. This condition can be mitigated by moving the Tx and Rx closer to each other, setting their line-of-sight to 0 degrees (see item 1 on the previous page), and ensuring that there are no obstructions between the Tx and the Rx.
  • Page 20 If the ZeroWire deployment is a typical one-system per room, there is essentially no restriction. The transmitter’s Channel Selection feature picks the channel that is least susceptible to interference from the available six channels based on the result of its scan at power on. Some of the factors affecting how well the ZeroWire channels are isolated are listed below.
  • Page 21 The recommendations below should be used to determine the appropriate setting. 1. ZeroWire G2 Tx and / or Rx units cannot be used with earlier Zerowire Tx and / or Rx units. 2. Up to three ZeroWire G2 systems may be operated in the same room. The transmitters and receivers should be separated by at least 3 ft (1 m) within the room.
  • Page 22 Problem Possible Causes Indicator LED is not on. Loose Power Connector: Verify that the power source connector is fully inserted into the unit’s power connector. 'Y' Cable: If you are using the ‘Y’ cable to supply power to the unit, confirm that it is connected to a power supply and that the power supply is energized.
  • Page 23 a. The effective range may vary depending upon the environment in which the product is operating. Follow the product’s Setup section to achieve optimum performance and range.
  • Page 24 Name Horizontal Horizontal Vertical Vertical Frame / Field Rate ( Hz) Active Total Active Total Pixels Pixels Pixels Pixels 1080p60 1920 2200 1080 1125 1080p50 1920 2640 1080 1125 1080p24 1920 2640 1080 1125 1080p60 special mode 1920 2184 1080 1125 1080p50 special mode 1920...
  • Page 25 Prior to cleaning and surface disinfection, the unit should be turned OFF and disconnected from its power source. Cleaning: Thoroughly wipe all exterior surfaces with a lint-free cloth that has been dampened with soap and water only. Remove residual detergent by wiping all exterior surfaces with a lint-free cloth dampened with distilled water.
  • Page 26 (Rx) should not be installed in metal cabinets or surrounded by metallic objects, as this will prevent the Tx from communicating with the Rx. During installation the ZeroWire G2 link video quality should be tested with the Tx and Rx at different orientation angles, acceptable orientation angles are shown on page 11.
  • Page 29 0.01 0.12 0.12 0.23 0.38 0.38 0.73...
  • Page 32 Asia Pacific Corporate Headquarters Europe GSI Group Japan Corporation 5750 Hellyer Avenue Nijverheidscentrum 28 East Square Omori, San Jose, CA 95138 (USA) 2761 JP Zevenhuizen (ZH) 6-20-14 Minamioi, Shinagawa-ku Tel: 408 776 0085 The Netherlands Tokyo 140-0013, Japan Toll Free: 866 637 5237 Tel: + 31 180 63 43 56 ISO 9001:2008 and ISO 13485:2003;...

This manual is also suitable for: