Datavideo WM-1 Series Instruction Manual
Datavideo WM-1 Series Instruction Manual

Datavideo WM-1 Series Instruction Manual

Professional wall mount for robotic pan tilt head

Advertisement

Quick Links

WM-10

Advertisement

Table of Contents
loading

Summary of Contents for Datavideo WM-1 Series

  • Page 1 WM-10...
  • Page 2: Table Of Contents

    Disclaimer of Product & Services The information offered in this instruction manual is intended as a guide only. At all times, Datavideo Technologies will try to give correct, complete and suitable information. However, Datavideo Technologies cannot exclude that some information in this manual, from time to time, may not be correct or may be incomplete.
  • Page 3: Warranty

    Warranty Standard Warranty  Datavideo equipment is guaranteed against any manufacturing defects for one year from the date of purchase.  The original purchase invoice or other documentary evidence should be supplied at the time of any request for repair under warranty.
  • Page 4: Three Year Warranty

    Non-PCIe Card and third party provided PC components are covered for 1 year.  The three-year warranty must be registered on Datavideo's official website or with your local Datavideo office or one of its authorized distributors within 30 days of purchase. Disposal...
  • Page 5: Introduction

    Introduction WM-10 Professional Wall Mount is designed specifically for Datavideo PTR-10/10T Robotic Pan Tilt Head as well as the PTZ camera series (PTC-150/150T/200/200T). The two bubble level meters allow the user to align the mounted device horizontally. The four piece mounting kit is made of rugged metal and is easy to install on any walls.
  • Page 6 2. On the surface where the WM-10 is to be mounted, drill four holes spaced according to the dimensions indicated in the diagram below. Then follow the procedure in the next section to assemble and install the WM-10.
  • Page 7: Procedure

    Procedure The diagram below is an exploded-view drawing of WM-10, and the numbers correspond to the respective installation steps. Bubble Level Meter...
  • Page 8 1. Align the wall plate with the four holes drilled in Pre-Work then use four expansion bolts to secure the wall plate. See the diagram below. 2. Assemble the left bracket to the wall plate with two M5x20 nickel plated hex socket cap screws as shown in the diagram below.
  • Page 9 3. Assemble the right bracket to the wall plate with two M5x20 nickel plated hex socket cap screws as shown in the diagram below. 4. Place the round rod in between the left and right brackets then secure it in position by fastening two M5x20 nickel plated hex socket cap screws to the respective holes on the brackets as shown in the diagram below.
  • Page 10 5. Insert the base plate between the left and right brackets then secure it in position by fastening six M5x20 nickel plated hex socket cap screws to the respective holes on the brackets as shown in the diagram below. The inner rails on the right and left brackets should allow you to move the base plate back and forth.
  • Page 11: Installing Ptr-10/10T

    Installing PTR-10/10T To mount the PTR-10/10T to the WM-10, first place it on the base plate of the WM-10 such that the four screw holes at the bottom of the PTR-10/10T base are aligned with the screw holes found in the base plate as indicated in the diagram below.
  • Page 12 If after installation, the PTR-10/10T vibrates, you may enhance the installation by securing the base with four M3 x 8mm screws. The additional screw holes are depicted in the diagram below.
  • Page 13: Installing Ptc-150

    Installing PTC-150 Before installation, first make sure you have the following:  PTC-150  Standard accessories of PTC-150 Ceiling bracket M4 screw x 4  WM-10 wall mount To mount the PTC-150 on the WM-10, use four M4 screws to secure each of the upper and lower plates of the ceiling bracket to the base plate of WM-10 and bottom of the PTC-150 respectively.
  • Page 14 The WM-10 with the PTC-150 mounted is shown in the diagram below.
  • Page 15: Frequently Asked Questions

    Frequently Asked Questions This section describes problems that you may encounter while using WM-10. See related items for suggested solutions. If problem still exists, please contact your distributor or the service center. No. Problems Solutions PTR-10/10T vibrates after If after installation, the PTR- installation.
  • Page 16: Dimensions And Weight

    Dimensions and Weight Unit: mm Weight: 4.0 Kg (8.80 lb) Maximum load: 100 Kg...
  • Page 17: Specifications

    Specifications Model No. WM-10 Name Professional Wall Mount for Robotic Pan Tilt Head Weight 4 kg (8.80 lb) Dimensions 416 x 200 x 126 mm Max. Load 100 kg Applicable PTR-10 series Products PTC-140 series PTC-150 series PTC-280 series PTC-300 series...
  • Page 18 Notes...
  • Page 19 Notes...
  • Page 20: Service And Support

    Datavideo Technologies Co., Ltd. All rights reserved 2020 May-21.2021 Ver:E2...

This manual is also suitable for:

Vm-11

Table of Contents