Visit website for available
languages of this document.
DESCRIPTION
10STRIKERE34
¾" Strike
(10STRIKEREV34)
UL294 & UL1034 REQUIREMENTS
Indoor use only.
Wiring methods shall be in accordance with NFPA70.
10STRIKEREV is intended to be used with UL-listed, rim type, fire exit hardware, Von Duprin LLC, Model 99-F.
10STRIKEREV shall not installed in the fail-secure mode unless permitted by the local Authority Having Jurisdiction (AHJ), and shall not impair panic hardware
operation.
Remove the "Listed Fire Rated Hardware" label if the 10STRIKEREV is used in the fail-safe operation. Using these strikes in fail-safe operation negates the
fire rating. 10STRIKEREV is fire rated in fail-secure operation only.
10STRIKEREV are access control unit accessories intended to be controlled by an access contol system. The purpose of access control systems is to provide a
means for controlling lock and unlocking external and internal doors of a premise.
GENERAL SAFETY
Shut off all power going to header before attempting any wiring procedures.
!
Maintain a clean and safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
CAUTION
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board,
ensure you dissipate your body's ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA,
Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
©BEA
| Original Instructions
75.5012.01 RIM EXIT ELECTRIC STRIKE 20210121
½" Strike
10STRIKERE34
(10STRIKEREV12)
RIM-EXIT ELECTRIC STRIKE
Rim-exit electric strike for access doors
with ½" and ¾" housing thickness
TECHNICAL SPECIFICATIONS
Operating voltage
12 or 24 VDC
Current draw
540mA (12 VDC)
270mA (24 VDC)
Operating temperature
14 – 120 °F (-10 – 49 °C)
Humidity
0 – 85% non-condensing
Static strength
1500 lbs (680kg)
Dynamic strength
70 ft-lbs
Endurance
250,000 cycles (UL-tested)
1,000,000 cycles (factory-tested)
Lock mode
field selectable fail-safe or fail-secure
Performance level
destructive attack: level I
line security: level I
standby power: level I
endurance: level IV
Material (strike body)
brushed stainless steel (US32D)
Frame application
metal / wood
Latch throw
¾" or ½"
(housing thickness)
Specifications are subject to change without prior notice.
All values measured in specific conditions.