9-2. Disassembling/Reassembling 7.5 kW Generator

B
Apply Loctite 242 or
equivalent to screw
before installing.
Belt/Hydraulic-Drive Generator
Remove brush holder
before disassembling
rotor and stator.
2
1
Use Section 8-2 to determine if trouble is
in stator, rotor, control box, or combina-
tion of these components.
1
Rotor
2
Stator Assembly
!
Use hoist and lifting strap to care-
fully
disassemble/reassemble
generator .
!
Do not damage rotor or stator
windings during this procedure.
.
Mark electrical leads and remove
brush holder assembly before dis-
assembling unit.
Reassemble generator parts using
torque values in table.
Reconnect all leads. Use cable ties to
secure leads away from moving or hot
parts.
Apply SAE 30W oil to
both ends of studs
before installing.
Tools Needed:
A
B
A
803 235
Torques:
.
95 in lb (10.7 N
m)
.
38 ft lb (52 N
m)
(Belt Tensioner)