Configuring Line Crossing Detection - Honeywell HEICC-2736-WI User Manual

Explosion-proof bullet camera
Table of Contents

Advertisement

User Manual of Explosion-Proof Bullet Camera
when the button turns to
4. Draw area.
1) Select the Region No.in dropdown list.
2) Click
3) Click on the image to specify a corner of the rectangle, and right-click the mouse after
four corners are configured.
Up to four areas are supported. You can click
5. Configure the parameters for each defense region separately.
 Threshold: Range [0-10s], the threshold for the time of the object loitering in the region. If
you set the value as 0, alarm is triggered immediately after the object entering the region.
 Sensitivity: Range [1-100]. The value of the sensitivity defines the size of the object which
can trigger the alarm, when the sensitivity is high, a very small object can trigger the
alarm.
6. Click
schedule configuration is the same as the settings of the arming schedule for motion
detection. Refer to Section 5.2.1 Configuring Motion Detection.
7. Click
Surveillance Center, Send Email, Upload to FTP/Memory Card/NAS, Trigger Alarm Output and
Trigger Recording are selectable. Refer to Section 5.2.1 Configuring Motion Detection.
8. Click

5.3.3 Configuring Line Crossing Detection

The virtual plane detection can be adopted for the intrusion detection. Once the virtual plane is
detected being traversed according to the configured direction, a set of alarm action is triggered.
Steps:
1. Enter the Line Crossing Detection interface:
Configuration >Event > Smart Event > Line Crossing Detection
2. Check the Enable checkbox to enable the line crossing detection function.
3. Select the Line in dropdown list to configure.
4. The event triggered and park action related PTZ movement will be locked for 180 seconds
after you enter the line crossing detection interface. Optionally, you can click the
to draw a rectangle on the image as a defense region.
tab to enter the arming schedule setting interface. The time
tab to select the linkage method taken for intrusion detection, Notify
to save the settings.
button to manually activate the movement, or lock the movement
by clicking it.
to clear the areas you drawn.
45

Advertisement

Table of Contents
loading

Table of Contents