Acer AL1916 Service Manual page 19

Hide thumbs Also See for AL1916:
Table of Contents

Advertisement

Support Modes
There will be 28 total support modes to accommodate the above mode and other video modes within the frequency range of the
monitor.
85Hz refresh rate Support
Monitor should display 85Hz refresh rate mode as emergency mode.
Monitor should display "Out of Range" warning menu at this mode.
Video input Connector
Analog Video input Connector: 15pins mini D-Sub
Table 2.4.5. Pin assignment for D-sub connector
PIN NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Separate Sync
RED VIDEO
GREEN VIDEO
BLUE VIDEO
GROUND
GROUND
RED GROUND
GREEN GROUND
BLUE GROUND
PC5V (+5V DDC)
CABLE DETECTION
GROUND
SDA
H.SYNC
V.SYNC
SCL
- 19 -