System Flow Principle; Refrigeration Flow Chart - Haier HRF-633CJB Service Manual

Table of Contents

Advertisement

SERVICE MANUAL
Model: HRF-633CJB
valve first and next comes to ice maker, if cool water valve needs water when ice maker valve is inlet
water, both two valve will be supplied water at the same time.
Chapter 6 System flow principle

6-1. Refrigeration flow chart

Principle diagram and description of the refrigeration cycle
The refrigerant is compressed in the compressor, from there, it enters the dry filter, de-dewing tube,
and the condenser, and goes into the evaporator after being throttled and decompressed in the
capillary tube. Finally, it returns to the compressor through the air return tube.
Principle diagram of the refrigeration cycle:
Issue 2009-12-24
Rev. Ref0912S024V0
23